Mount the Butler PRO in a standard 19-inch rack system. Use appropriate rack
screws, cage nuts and spring clips for mounting.
Unit distribution
As the Butler PRO has no active cooling, place a
maximum of two units together, leave one unit free
or place a passive device, followed by the next two
units. Additionally care for:
y
closing of unused units with rack plates
y
mounting in a fan-ventilated closed rack
y
placement of the rack in an air conditioned room
Connect the Butler PRO with the outputs of the Ethernet switch and with power.
When installing and mounting more than one Butler PRO in factory state,
make sure that only one Butler PRO gets connected and configured at
one time. If connecting more than one device with the factory IP address
(192.168.123.1) the Ethernet connection will not work
User interface
The Butler Pro comes with a circular keypad and an LC display for operation
and setup. During regular operation the Butler PRO displays status and opera-
tional messages on the display. When in setup mode, parameters and values are
displayed, the keypad is used for selecting parameters and changing values. Only
keypads, that are allowed at a certain state, are lit up, either in operational or in
setup mode. This picture is the Butler PRO DMX.
System display
Cursor keys
OK key (center)
OK
Status >
online DMX 35Fps
Содержание Butler PRO
Страница 1: ...Butler PRO Setup Manual...
Страница 5: ...5 Setup Manual Butler PRO English...
Страница 26: ...26 Setup Manual Butler PRO Deutsch...
Страница 46: ...46 Setup Manual Butler PRO Appendix...
Страница 47: ...47 Setup Manual Butler PRO Dimensions Abmessungen All dimensions in mm Alle Abmessungen in mm 482 146 44...
Страница 48: ...48 Setup Manual Butler PRO Notes Notizen...
Страница 49: ...49 Setup Manual Butler PRO Notes Notizen...
Страница 50: ...50 Setup Manual Butler PRO Notes Notizen...
Страница 51: ...51 Setup Manual Butler PRO Notes Notizen...