Specifications
Multiload 5 (12 V)
Multiload 7
Multiload 10 (12 V)
Charger Type
8 stage automatic
Input Voltage
220 – 240 V~, 50/60 Hz
Input Power
154 W
215 W
307 W
Output Voltage
12 V DC
12 V DC
12 V DC
Output Current
5 A
7 A
10 A
Min. Star Voltage
2 V
2 V
2 V
Back Drain
4 mA
4 mA
4 mA
Current Fuse Rating
250 V AC, T3,15 A
250 V AC, T3,15 A
250 V AC, T3,15 A
Charge Control
Desulphation
Pulse charge up to 11 V
Soft Start
Half of the rated set current up to 12,5 V
Bulk
5 A up to
14,1 V (GEL)
14,4 V (AGM)
14,7 V (WET)
14,7 V (CALCIUM)
7 A up to
14,1 V (GEL)
14,4 V (AGM)
14,7 V (WET)
14,7 V (CALCIUM)
10 A up to
14,1 V (GEL)
14,4 V (AGM)
14,7 V (WET)
14,7 V (CALCIUM)
Absorption
Constant voltage until
current drops to
0,75 A
Constant voltage until
current drops to
1,05 A
Constant voltage until
current drops to 1,5 A
Battery Test
Monitors voltage for 90 seconds
Recondition
Constant current (0,75
A) for 30 minutes or
for 4 hours limited to:
14,1 V (GEL), 14,4 V
(AGM), 16 V (WET)
16 V (CALCIUM)
Constant current (1,05
A) for 30 minutes or
for 4 hours limited to:
14,1 V (GEL), 14,4 V
(AGM), 16 V (WET)
16 V (CALCIUM)
Constant current (1,5
A) for 30 minutes or
for 4 hours limited to:
14,1 V (GEL), 14,4 V
(AGM), 16 V (WET)
16 V (CALCIUM)
Float
13,7 V – also with pulse feature
Pulse
12,6 V – 14,1 V, 5-2 A (GEL) 12,6 V – 14,4 V, 5-2 A (AGM)
12,6 V – 14,7 V, 5-2 A (WET) 12,6 V – 14,7 V, 5-2 A (KALZIUM)
Efficiency
ca. 85 %
Thermal Protection
65 °C +/- 5 °C
Cooling Fan
Automatic temperature controlled
Ambient Temperature
-20 °C to 50 °C, output power is reduced
automatically at high temperatures
Over Voltage Protection
The 12V charger will automaticallyp rotection if the
voltage is higher than 17.5 V
Battery Range
Deep Cycle
12 – 150 Ah
20 – 240 Ah
40 – 400 Ah
Types of Batteries
Most types of lead acid batteries including Calcium, GEL and AGM
Dimensions (L×W×H)
197 x 116 x 62 mm
197 x 116 x 62 mm
197 x 116 x 62 mm
Weight
1,05 kg
1,05 kg
1,1 kg
45