6.2.8. Transmitter commands
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
TX.NAME R/W
XXXX
X=[A…Z]
Transmitter
name
TX.FREQ R/W XXXXXX
Working frequency of the modulator in kHz "232553" =>
232.553 MHz
TX.3DB R/W [0..9999]
Sets the triggering threshold for the 3 dB alarm. Example "250"
=> 250 W
TX.ALARM.3DB
R
"ON" or "OFF"
ON => 3 dB alarm, OFF => No alarm.
TX.FAULT
R
"FAULT" or "OK"
Fault state of transmitter
TX.ALARM.VSWR
R
"ON" or "OFF"
ON => VSWR alarm, OFF => No alarm
TX.LOCALMODE
R
"LOCAL" or "REMOTE"
Single transmitter, indicates the local or remote mode
TX.VSWR.MAX
R/W
XX.X X=[0..9]
Sets the triggering threshold for the VSWR alarm. Must be of
type "XXX"."020" => VSWR = 2. Do not use "2" or "1.4".
TX.OPMODE
R/W
"ON" or "OFF"
Single transmitter control
TX.PCAP
R
[0..999]
Amplifier nominal power: example "300"=>300W
TX.PFWD
R
[0..9999]
Measure of direct power. examples: "20" or "300" => 300W
TX.PREF
R
xxx.x x=[0..9]
Measure of reflected power: "20" => 2W
TX.PWR
R/W
[0..9999]
Sets the output power. From "0" .. "9999"
TX.RFPRESENT
R
"PRES" or "NOT PRES"
Indicates if the single transmitter output power is present
TX.TYPE
R
xxx x=[A..Z;0..9]
System type: example "1000-NT" For a 1000 W transmitter
with Nephtys central unit
TX.VSWR
R
XX.X X=[0..9]
VSWR measure "01.0" or "20.0"
TX.WARNING
R
"ON" or "OFF"
Single transmitter. Warning state of single transmitter
TX.SBY
R/W
"ON" or "OFF"
Enables/disables the standby mode
TX.3DB.AUTO
R/W
"ON" or "OFF"
If ON set the 3 dB level to TX.PWR/2. If TX.3DB is modified,
switches automatically to OFF
TX.LINK
R
"OPEN" or "CLOSE"
State of the CAN bus link
TX.INTERLOCK
R
"CLOSE" or "OPEN"
State of the safety loop
6.2.9. Status commands
NAME
Access
(R/W)
Possible value on the
serial port of the unit
Comments
STAT.LINK
R
"OPEN" or "CLOSE"
State of the CAN bus link
STAT.INTERLOCK.ANTENNA
R
"CLOSE" or "OPEN"
State of the antenna safety loop
STAT.INTERLOCK.LOAD
R
"CLOSE" or "OPEN"
State of the load safety loop
STAT.SWRF
R
"ON" or "OFF"
State of the RF switch
STAT.SECTEMP
R
"ON" or "OFF"
State of the temperature safety
STAT.DCOK1
R
"ON" or "OFF"
Indicates if the PSU 1 of the amplifier is "ON" or
"OFF"
STAT.DCOK2
R
"ON" or "OFF"
Indicates if the PSU 2 of the amplifier is "ON" or
"OFF"
STAT.DCOK3
R
"ON" or "OFF"
Indicates if the PSU 3 of the amplifier is "ON" or
"OFF"
STAT.DCOK4
R
"ON" or "OFF"
Indicates if the PSU 4 of the amplifier is "ON" or
"OFF"
STAT.SECPREF
R
"ON" or "OFF"
Indicates if the reflective protection is enabled
STAT.SECPIN
R
"ON" or "OFF"
Indicates if the input power is greater than the
hardware threshold
STAT.ALARMS
R
XXXXXXXX x=[0,1…F] Returnes a 32 bit value indicating current alarms
STAT.CURRENT.IN R
"1+OPT" or "1+2" or
"2+OPT"
Indicates the channels used for channels 1 and 2