Helios FM 20/100 W, user manual– 12/2011
Page 49
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
www.ecreso.com – [email protected]
6.2.
Serial commands
6.2.1. System commands
NAME
Access
(R/W)
Possible value on the serial port
of the unit
Comments
SYS.RST
W
Reset of all parameters.
SYS.RST.CPU W "RST"
General reset of the µc. Sends the return
code: RST
SYS.RST.EXC
W
General reset of the exciter
SYS.RAZ
W
"RAZ"
Reloads NVRAM default values
SYS.TYPE
R
xxx x=[A..Z;0..9]
Unit type: example "G75" for Goliath 750 W
SYS.PCAP R
[0..999]
Nominal power of the unit: example
"300"=>300 W
SYS.SOFTREL
R
xx.xx.xx x=[0..9]
Software version: example "3.0.1"
SYS.SOFTREL.LIST
R
xx.xx.xx x=[0..9]
List of the exciter software versions
CPU;DSP;FPGA;IP;EXC;A/IP;TUN
SYS.HARDREL
R
xx.xx.xx x=[0..9]
Hardware version: example "3.0.1"
SYS.NAME R/W
XXXX
X=[A…Z]
Equipment
name
SYS.TIME R/W
HH:MM:SS
Reads
and
sets the amplifier time
SYS.DATE R/W
DD/MM/YY
Reads
and sets the amplifier date
SYS.LOCALCOM.SPEED R/W 9600,19200,38400,57600,115200 Speed
of
the front panel serial port
SYS.COM1.SPEED R/W
9600,19200,38400,57600,115200 Speed of the rear panel serial port 1
SYS.COM2.SPEED R/W
9600,19200,38400,57600,115200 Speed of the rear panel serial port 2
SYS.COM1.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the rear panel serial
port
SYS.COM2.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the rear panel serial
port
SYS.LOCALCOM.ECHO
R/W
"ON" or "OFF"
Adds the local echo on the front panel serial
port
SYS.PASSWORD
R/W
xxx x=[A..Z;0..9]
Password for the console and front panel
display. ‘NONE’ disables the password
SYS.PASSWORD.RESET
R/W
xxx x=[A..Z;0..9]
Creates a text string to unlock the password
if it has been forgotten
SYS.LOG
R
SYS.CID R/W
[0..31]
Unit
identifier used by the CAN bus.
SYS.DATE.CALIB
R
DDMMYYYY
Date of the last calibration
SYS.SN R
YYMMXXXX
A,M,X=[0..9]
Serial number of the unit: Y => year, M =>
month, X => number
SYS.UPTIME R
[0..99999999]
Indicates the number of working hours since
commissioning
SYS.OPT.LIST R
RF,RC,AIP,TUN,IP,COM,REC
List of implemented options
SYS.IP.ADR
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP address of the optional IP board
SYS.IP.MASK
R/W
XXX.XXX.XXX.XXX X=[0…9]
IP mask of the optional IP board
SYS.GPIO.IN.ACT
R
XX X=[A..F;0..9]
Indicates the corresponding RC when
managed manually (see
SYS.GPIO.IN.MASK)
SYS.GPIO.OUT.ACT
R/W
XX X=[A..F;0..9]
Enables the corresponding RM when
managed manually (see
SYS.GPIO.OUT.MASK)
SYS.GPIO.IN.MASK
R/W
XX X=[A..F;0..9]
Sets the RC control either by the control
board or manually. Hexadecimal code: each
bit corresponds to an input. Ex: A1
(10100001) indicates the RC 1, 6 and 8 are
managed manually