Chapter 3 Web-page Management 

Users  cannot  use  front  buttons  to  set  configuration,  and  can  only  control  and  set  the 

configuration  in  computer  by  connecting  the  device  to  web  NMS  Port.  Users  should  ensure 

that  the  computer’s  IP  address  is  different  from  the  EPS-HDM1001 IP  address;  otherwise,  it 

would cause IP conflict. 

3.1 Login 

 

The factory default IP address is 192.168.0.136 and users can connect the device and web NMS 

through this IP address.   

Connect the PC (Personal Computer) and the device with a net cable, and use ping command to 

confirm  they  are  on  the  same  network  segment.  For  instance,  the  PC  IP  address  is 

192.168.99.252, we then change the device IP to 192.168.99.xxx (xxx can be 0 to  255 except 

252 to avoid IP conflict).   

Use  web  browser  to  connect  the  device  with  PC  by  inputting  the  device’s  IP  address  in  the 

browser’s address bar and press Enter. 

It  will  display  the  Login  interface  as  Figure-1.  Input  the  Username  and  Password  (Both  the 

default  Username  and  Password  are  “admin”.)  and  then  click  “Login”  to  start  the  device 

setting. 

 

 

 

Figure-1 

3.2 Operation 

When  we  confirm  the  login,  it  displays  Homepage  as  Figure-2  where  users  can  have  an 

overview of the device’s system information. 

http://192.168.0.136 

Содержание EPS Pro Series

Страница 1: ...EPS HDM1001 HDMI to DVBT Modulator ELECTROCRAFT AUSTRALIA 36 Binney Road Marayong NSW 2148 T 02 8811 5155 F 02 9831 2139 www electrocraft com au ...

Страница 2: ...F out The signals source could be from STB satellite receiver closed circuit television cameras and antenna etc Its output signal is to be received by TVs or STBs etc 1 2 Key Features Support 1 HDMI channel in for encoding 1 CC input port Support MPEG 2 video encoding Support MPEG1 Layer 2 audio encoding Support DVB C T ATSC ISDB RF out put Support Web management 1 3 Specifications HDMI Encoding S...

Страница 3: ... Modulator Section Standard DVB T COFDM Bandwidth 2M 3M 4M 5M 6M 7M 8M Constellation QPSK 16QAM 64QAM Code rate 1 2 2 3 3 4 5 6 7 8 Guard Interval 1 32 1 16 1 8 1 4 Transmission Mode 2K 8K MER 35dB RF frequency 100 1000MHz 1KHz step RF output level 0 47dBm 1db step ISDB Modulator Section Standard ARIB STD B31 Constellation QPSK 16QAM 64QAM Guard Interval 1 32 1 16 1 8 1 4 Transmission Mode 2K 4K 8...

Страница 4: ...EPS HDM1001 Encoder Modulator User Manual Upgrade Web update General Power supply DC 12V Dimensions 203 144 52mm Weight 1kg 1 4 System Connection Samples 1 5 Appearance and Description ...

Страница 5: ... areas of high humidity Do not cover the device with elements that obstruct the ventilation slots If the network encoder has been kept in cold conditions for a long time keep it in a warm room minimum 2 hours before plugging into the mains Mount the device in vertical position with the connectors located on the top side When replacement parts are required be sure the service technician has used re...

Страница 6: ...case of connecting to a wired network connect the encoder Ethernet port and terminal s Ethernet port with ethernet cable In case of connecting wireless network following Step 2 connect the encoder Ethernet port and router port with Ethernet cable Power supply connection a Connect the earth cable b Connect the power plug to the unit mains connector c Connect the power plug to the mains socket ...

Страница 7: ...d the device with a net cable and use ping command to confirm they are on the same network segment For instance the PC IP address is 192 168 99 252 we then change the device IP to 192 168 99 xxx xxx can be 0 to 255 except 252 to avoid IP conflict Use web browser to connect the device with PC by inputting the device s IP address in the browser s address bar and press Enter It will display the Login...

Страница 8: ... users can configure the encoder parameters and select the modulating standard as Figure 3 Figure 3 System Network Click Network it will display the interface as Figure 4 where to set network parameters Here user can change the device network configuration as needed User can click any item here to enter the corresponding interface to check information or set the parameters ...

Страница 9: ...ware it will display the screen as Figure 5 Figure 5 System Password From the menu on left side of the webpage clicking Password it will display the screen as Figure 6 where to set the login account and password for the web NMS After inputting the current and new Username and Password click Apply to save the configuration ...

Страница 10: ...l Figure 6 System Log From the menu on left side of the webpage clicking Log it will display the screen as Figure 7 Figure 7 Configuration From the menu on left side of the webpage clicking Configuration it will display the screen as Figure 8 ...

Страница 11: ...EPS HDM1001 Encoder Modulator User Manual Figure 8 ...

Отзывы: