Ecraft EPS Pro Series Скачать руководство пользователя страница 5

 

 

EPS-HDM1001 Encoder Modulator User 
Manual 

 

Chapter 2 Installation Guide 

Safety Instructions 

WARNING: Hot plug is not allowed since it may cause system halted. 

To prevent fire or electrical shock, do not expose the device to rain or moisture. 

 

  The network encoder is powered with a voltage of 12V DC. The power supply voltage must 

not  exceed  the  recommended  voltage,  which  otherwise  may  cause  irreparable  damage  to  the 

device and the invalidation of the warranty. Therefore:   

 

Do not replace power supply with a voltage greater than 12V DC.   

 

Do not connect the device to the power if the power cord is damaged.   

 

Do not plug the device into mains supply until all cables have been connected correctly.   

 

Do not cut the cord.   

Avoid placing the device next to central heating components and in areas of high humidity.   

Do not cover the device with elements that obstruct the ventilation slots.   

If the network encoder has been kept in cold conditions for a long time, keep it in a warm room 

minimum 2 hours before plugging into the mains.   

Mount the device in vertical position with the connectors located on the top side.   

When replacement parts are required, be sure the service technician has used replacement parts 

specified  by  the  manufacturer  or  have  the  same  characteristics  as  the  original  part. 

Unauthorized substitutes may result in fire, electric shock or other hazards. 

Safety  check-  Upon  completion  of  any  service  or  repairs  to  this  device,  ask  the  service 

technician to perform safety checks to determine that the device is in proper condition. 

 

Installations 

RISK OF damage to the unit 

Mechanically  handling  the  unit  may  result  in  damage.  Do  not  connect  the  unit  to  the  power 

supply before or during assembly. Connect the unit as below instructed.   

Ground
ing 
Ground
ing 

 

Содержание EPS Pro Series

Страница 1: ...EPS HDM1001 HDMI to DVBT Modulator ELECTROCRAFT AUSTRALIA 36 Binney Road Marayong NSW 2148 T 02 8811 5155 F 02 9831 2139 www electrocraft com au ...

Страница 2: ...F out The signals source could be from STB satellite receiver closed circuit television cameras and antenna etc Its output signal is to be received by TVs or STBs etc 1 2 Key Features Support 1 HDMI channel in for encoding 1 CC input port Support MPEG 2 video encoding Support MPEG1 Layer 2 audio encoding Support DVB C T ATSC ISDB RF out put Support Web management 1 3 Specifications HDMI Encoding S...

Страница 3: ... Modulator Section Standard DVB T COFDM Bandwidth 2M 3M 4M 5M 6M 7M 8M Constellation QPSK 16QAM 64QAM Code rate 1 2 2 3 3 4 5 6 7 8 Guard Interval 1 32 1 16 1 8 1 4 Transmission Mode 2K 8K MER 35dB RF frequency 100 1000MHz 1KHz step RF output level 0 47dBm 1db step ISDB Modulator Section Standard ARIB STD B31 Constellation QPSK 16QAM 64QAM Guard Interval 1 32 1 16 1 8 1 4 Transmission Mode 2K 4K 8...

Страница 4: ...EPS HDM1001 Encoder Modulator User Manual Upgrade Web update General Power supply DC 12V Dimensions 203 144 52mm Weight 1kg 1 4 System Connection Samples 1 5 Appearance and Description ...

Страница 5: ... areas of high humidity Do not cover the device with elements that obstruct the ventilation slots If the network encoder has been kept in cold conditions for a long time keep it in a warm room minimum 2 hours before plugging into the mains Mount the device in vertical position with the connectors located on the top side When replacement parts are required be sure the service technician has used re...

Страница 6: ...case of connecting to a wired network connect the encoder Ethernet port and terminal s Ethernet port with ethernet cable In case of connecting wireless network following Step 2 connect the encoder Ethernet port and router port with Ethernet cable Power supply connection a Connect the earth cable b Connect the power plug to the unit mains connector c Connect the power plug to the mains socket ...

Страница 7: ...d the device with a net cable and use ping command to confirm they are on the same network segment For instance the PC IP address is 192 168 99 252 we then change the device IP to 192 168 99 xxx xxx can be 0 to 255 except 252 to avoid IP conflict Use web browser to connect the device with PC by inputting the device s IP address in the browser s address bar and press Enter It will display the Login...

Страница 8: ... users can configure the encoder parameters and select the modulating standard as Figure 3 Figure 3 System Network Click Network it will display the interface as Figure 4 where to set network parameters Here user can change the device network configuration as needed User can click any item here to enter the corresponding interface to check information or set the parameters ...

Страница 9: ...ware it will display the screen as Figure 5 Figure 5 System Password From the menu on left side of the webpage clicking Password it will display the screen as Figure 6 where to set the login account and password for the web NMS After inputting the current and new Username and Password click Apply to save the configuration ...

Страница 10: ...l Figure 6 System Log From the menu on left side of the webpage clicking Log it will display the screen as Figure 7 Figure 7 Configuration From the menu on left side of the webpage clicking Configuration it will display the screen as Figure 8 ...

Страница 11: ...EPS HDM1001 Encoder Modulator User Manual Figure 8 ...