background image

6

Model

Storage 

Volume

Dimensions

(Inches)

Piping Connections

Max. 

Working 

Pressure

Approx. 

shipping 

Wt.

Gals.

Ht. 

Dia.

Cold/Hot

In/Out

Heat Source

Supply/Return

(psi)

Lbs.

H2OST30

30

34.0

23.5

1

1

150

75

H2OST40

40

44.0

23.5

1

1

150

90

H2OST60

60

62.0

23.5

1

1

150

115

H2OST60L

60

46.0

28.0

1

1

150

110

H2OST80

80

56.0

28.0

1

1

150

140

H2OST80C

80

56.0

28.0

½

1

150

140

H2OST115

115

74.0

28.0

1

1

150

175

H2OST115C

115

74.0

28.0

1

½

1

150

175

HOT WATER BOOSTER / STORAGE TANKS

F

ully insulated 

steel tanks, 

including L4080B 

limit. Brass drain 

and T&P valves are 

factory installed. 

Dip tubes in tank 

located to circulate 

water through 

heat 

source and 

return to tank.

ST

AND

ARD MODEL H2OS

T

MODEL H2OS

T-C

Содержание H2O Series

Страница 1: ...ime of printing of this manual ECR International reserves the right to discontinue change specifications or system design at any time without notice and without incurring any obligation whatsoever Conforms to UL STD 174 Certified to CAN CSA STD C22 2 No 110 94 30 40 60 80 115 Gallon L Low Boy Profile C Commercial Pipe Connections ECR International Inc 2201 Dwyer Avenue Utica NY 13501 Tel 800 325 5...

Страница 2: ......

Страница 3: ...s a presence of hazards that WILL cause severe personal injury death or substantial property damage Indicates a presence of hazards that CAN cause severe personal injury death or substantial property damage Indicates a presence of hazards that will or can cause minor personal injury or property damage Indicates special instructions on installation operation or maintenance that are important but no...

Страница 4: ...ll those contained in component manufacturers manuals before installing starting up operating maintaining or servicing the storage tank CAUTION To reduce the risk of excessive pressures and temperatures in this storage tank install temperature and pressure protective equipment required by local codes but no less than a combination temperature relief valve certified by a nationally recognized testi...

Страница 5: ...erly or if it has been damaged or dropped 5 This storage tank should be serviced only by qualified personnel Contact nearest authorized service facility for exami nation repair or adjustment WARNING DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance If you smell gas vapors DO NOT try to operate any appliance DO NOT touch any electrical ...

Страница 6: ...0 23 5 1 1 150 115 H2OST60L 60 46 0 28 0 1 1 150 110 H2OST80 80 56 0 28 0 1 1 150 140 H2OST80C 80 56 0 28 0 1 1 150 140 H2OST115 115 74 0 28 0 1 1 150 175 H2OST115C 115 74 0 28 0 1 1 150 175 HOT WATER BOOSTER STORAGE TANKS Fully insulated steel tanks including L4080B limit Brass drain and T P valves are factory installed Dip tubes in tank located to circulate water through heat source and return t...

Страница 7: ...n not be avoided a suit able drain pan must be installed under the storage tank and the drain pan must be connected to a drain The drain pan should be at least 2 deep with a length and width at least 2 greater than the total diameter of the unit and should be piped to an adequate drain Drain pans suitable for these storage tanks are available from your wholesale distributor Storage tank life depen...

Страница 8: ...t is present in the water A water softening system is recommended for areas with hard water In an area where the water quality is not known a water quality test should be performed WARNING Do not operate storage tanks in areas where the Ph is above 8 0 or below 6 0 and or with chloride concentrations greater than 80 parts per million ppm ECR s standard warranty does not cover problems caused by im...

Страница 9: ... and de energizes the circulator and the heat source Temperature Adjustment The tank aquastat controls the maximum water temperature in the storage tank If it is set too high the resulting hot water can cause painful scalding with possible serious and permanent injury The temperature at which this occurs varies with a person s age and the length of time in contact with the hot water The slower res...

Страница 10: ...terial As a preventive measure water should be drawn from the drain valve until it runs clear and the installation of a water filter should be considered 4 Inspect Anode annual The purpose of the magnesium anode is to reduce the damaging effects of aggressive water on the water heater Aggressive water will cause the anode s to erode The anode s must be inspected at least annually to determine whet...

Страница 11: ...11 Hot Water Booster Storage Tanks Description Part Number 1 Aquastat Well Stainless Steel 240009522 2 Aquastat 240009521 3 Drain Valve 3 4 Brass 240012194 4 Anode Rod 240010929 Replacement Parts ...

Страница 12: ...12 ...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...H2 O All specifications subject to change without notice 2022 ECR International Inc ECR International Inc 2201 Dwyer Avenue Utica NY 13501 Tel 800 325 5479 www ecrinternational com ...