geNeRAl PRODUCT INfORMATION
NOTICe
If excessive noise or vibration from unit mounted to
masonry block wall, verify unit is plumb and level. If
noise or vibration persists, contact distributor.
S1CV/
S1HV
or
Model
Max.
Length
equivalent
feet
Max.
lift
Max.
Trap
Height
liquid
line
Suction
line
“H”
“P”
o.D.
o.D.
09
100’
(30 m)
35’
(11 m)
20’
(6 m)
1/4"
1/2"
12
1/4"
1/2"
18
3/8"
5/8" *
24
3/8"
5/8" *
30
5/8"
3/4"
36
5/8"
3/4"
* Bush down at air handler
• Position unit as close as possible to center (left-to-
right) of wall. Grille on unit front must be accessible for
servicing.
Condensate Pump Kit Option
• verify condensate pump purchased with unit See
Table 2
.
• Floor-mounted units with floor-mounted condensate
pump optional toe kick kit. See Table 2
.
Optional Toe Kick Kit
• For floor-mounted UNHv units use optional toe kick kit.
See
Table 3
.
• Toe kick kit is required if floor mounting a condensate
pump under floor-mounted UNHv air handler.
Site Preparation
• Mount unit to vertical surface plumb and level to
prevent unit vibration and potential noise.
• Mount unit directly to smooth surface such as wallboard
or similar material.
• Mounting to masonry block wall,provide smooth
barrier between unit and masonry block surface to
absorb potential vibration and prevent formation of
condensation on the wall.
• Unit can be suspended from ceiling using threaded
rods.
Installation Considerations
• Determine best location for mounting unit for room air
circulation.
• Locate outdoor and indoor units as close together as
possible.
• Determine wiring, drainage and piping placement.
• Insure interconnect tubing is within listed limits. See
Table 1
.
Table 1
- Tubing Specifications - Both Tubes
Insulated
floor-Mounted Units
Air Handler
208/230v
115v
09 / 12
550001727
550001728
18 / 24
550001727
550001727
Toe kick kit is required when condensate pump is
mounted below floor-mounted air handler.
Ceiling-Mounted Units
Air Handler
208/230v
115v
09 thru 36
240006200
240006199
Air Handler
Part number
09 / 12
550001785
18 / 24
550001786
30 / 36
550001787
Required when condensate pump is
mounted below floor-mounted air
handler.
Table 2 - Condensate Pump Kits, UNHV 09-24
Table 3 - Toe Kick Kits
Ceiling Mounted Units
Air Handler
Kit #
09/12
550001915
18 / 24
550001916
30 / 36
550001917
Recommended when unit is ceiling
mounted
Table 4 - Drain Pan extension Kits