This illustration is for explanation purposes only.
The actual shape of your air condtioner may be
slightly different.
Copper lines must be insulated independently
CAUTION
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
A minimum pipe run of
9.84ft. [
3 metres
]
is
required to minimi
z
e vibration & excessive
noise.
Two of the A, B and C directions should
be free from obstructions.
INSTALLATION INSTRUCTIONS
6
CAUTIONS
One-Two
One-Three
One-Four
More than
4.72 in.[
12cm
]
Air fi
lter
Remote
controller
Air filter
Remote
controller
Remote
controller
Air filter
More than
5.9 in.
[
15cm
]
Air filter
Remote
controller
A
B
C
More than
78.74 in
[
200cm
]
Air out
M
o
re t
h
a
n
23.62
inc [
6
0
cm
]
More than
11.81in.[
30
cm]
Loop a
connective
cable
1
2
3
4
5
6
Fig.
2
More than
4.72 in.[
12cm
]
More than
4.72 in.[
12cm
]
More than
4.72 in.[
12cm
]
More than
3.93 in.[
1
0
cm
]
More than
23.62in. [60cm]