Declaration of Conformity 

Model No. MOG 550 (MOG = Mobile Ozone Generator) 
This unit fully complies with CE & FCC rules of EMC regulations.

 

EN 61000-61, EN 61000-62, EN 61010-1, EN 5501 EMC, FCC Part 15

 

Safety of Low Voltage Directive 73/23/EEC as Amended: EN 61010-1.

 

  

 

             

 

  

Warranty

 

ECOZONE warrants to the original retail purchaser or licensee of the TigerO 
(“Purchaser”) that the TigerO will conform to and perform in accordance with the 
published technical specifications and any accompanying written materials supplied 
by ECOZONE and will be free from defects in materials and workmanship under 
normal use and conditions for the applicable warranty period indicated below.  
This warranty does not extend to TigerO units which have been subject to misuse, 
accident, exposure to corrosive substances, tampering or use in a manner not 
approved by ECOZONE in writing.   
 
Warranty period is one year, commencing on the date of purchase. 
 
Under this warranty, Purchaser must first return the TigerO to ECOZONE, together 
with proof of purchase from an authorized dealer of ECOZONE (a “Dealer”),  
either directly, or through the Dealer from whom Purchaser purchased the TigerO,  
for examination by ECOZONE of entitlement under the terms of this warranty.  
All shipping, handling, travel, service call and/or other incidental and/or related 
charges are fully payable by Purchaser only and are not included in this warranty . 
 
In the case of a machine's fault which requires reparation that can be done by the 
customer on his site but must be executed, upon manufacturer's exclusive discretion, 
at the manufacturer's facility or in the case of manufacturer's decision to replace  
a machine, the customer should arrange on his account to deliver the machine to 
manufacturer's facility for reparation or for replacement by the manufacturer. 
 
 

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EITHER EXPRESS OR 
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH ARE EXPRESSLY EXCLUDED 
AND DISCLAIMED. ECOZONE WILL NOT BE LIABLE FOR LOSS OF PROFITS, ANY 
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES WHICH PURCHASER MAY 
SUSTAIN, OR PUNITIVE DAMAGES, EVEN IN THE EVENT OF NOTICE OF THE 
POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL LIABILITY UNDER THIS 
WARRANTY EXCEED THE PURCHASE PRICE OF THE ACTIVO PRODUCT. SOME STATES 
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE 
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE 
ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY 
GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS 
WHICH VARY FROM STATE TO STATE. 

 

Содержание TigerO

Страница 1: ...1 TigerO User Manual Version 2019 Ecozone Technologies Ltd ...

Страница 2: ... 2 Unpacking 3 General Information 4 Schematics 5 Safety Precautions Warnings 6 Control Panel 7 Operation Instructions 8 Maintenance and Service 9 10 Trouble Shooting 11 Electrical Schematics 12 Declaration of Conformity 13 Warranty 14 Contact Information 15 ...

Страница 3: ...Professionals Unpacking Open the top flaps of the carton and remove the inner supporting walls Lift the unit up and gently place it on its wheels Install the handle on both sides of the machine The handle s tightening screw on the right side ...

Страница 4: ...erative life time and high reliability Main Specification Input Voltage 230V 50Hz Power Consumption 420 W Overload Current Protection 4A Output Air Flow Rate 600 m h Ozone Generation Rate 12 5g h Weight Net 30 kg Gross 30 kg Dimensions Height 88 cm with handle up Width 36 cm Depth 33 5 cm Color Black and Yellow Main Features Trackless wheels Foldable handle Metal enclosure coated with anti rust po...

Страница 5: ...5 Schematics Ecozone Technologies has a policy of continuous product improvement and reserves the right to modify or change this specification at any time without notice ...

Страница 6: ...er pull the plug by the cord itself DO NOT enter the treated room during the operation of the machine This machine is equipped with a ventilation inlet and outlet DO NOT BLOCK inlet or outlet nor place any foreign objects in their vicinity which may block the air flow Place the machine in the CENTER of the room This unit is supplied with an earthed cable Attempting to bypass the earth or to connec...

Страница 7: ... Switch with Over Load Current protection Orange Light Indicator Ozone Generator is ON Six Position Times Selector switch 1 60 minutes Operation modes There are two operation modes which are selected by the Key Switch Normal and Remote In Normal operation mode the machine is controlled by the Six Position Times Selector on the operation panel In Remote operation mode the machine is controlled by a...

Страница 8: ...rt running and air will be emitted from the outlet mesh on the upper back side 4 Set the needed operation time by the Times Selector Switch on the operation panel 5 Press the Start button The Red light will turn OFF and the Orange ozone Light indicator will turn ON withing 2 seconds Leave the room immediately And close the door behind you 6 After the generation time is completed according to the s...

Страница 9: ...rated and the Red light will turn OFF 13 Stopping the operation of the TigerO must be made only by disconnecting the electricity from the Remote control timer Note If the Orange light is not turned ON and the Red light is still staying ON Error this is an indication of a failure See Trouble shouting Warning Do not attempt to re enter the room while it contains ozone Important After the treatment i...

Страница 10: ...d and washed or replaced from time to time and depending on operation times and conditions Fig 1 For cleaning or replacing the air filter use a screw driver to open the 2 screws which connect the filter housing on its top side to the front side of the machine Fig 1 Insert the screw driver in a hole in the mesh of the filter housing to gently pull it out Fig 2 a b c d Open the 4 screws of the filte...

Страница 11: ...lide out each SCU from its two supporting long screws 5 Wash each SCU with tap water Fig 3 and clean it up to remove dust and dirt 6 Dry the SCU or gently wipe it with soft cloth 7 Slide back the SCUs on their supporting screws and tight them with their nuts Note Make sure the SCUs are directed correctly according to the signs 8 Reconnect the electrical plugs of the two SCUs 9 Place the dust filte...

Страница 12: ...ht is not turned ON and the Red light is still ON Error this is an indication of a machine s failure Please check the following to possibilities 1 The air filter housing is opened In this case please place it in its right position and tight up to the front side of the machine by its two connecting screws 2 The air filter is blocked In this case please open the 4 screws of the filter housing and cl...

Страница 13: ...l shipping handling travel service call and or other incidental and or related charges are fully payable by Purchaser only and are not included in this warranty In the case of a machine s fault which requires reparation that can be done by the customer on his site but must be executed upon manufacturer s exclusive discretion at the manufacturer s facility or in the case of manufacturer s decision ...

Страница 14: ...14 Contact Information Ecozone Technologies Ltd Hasharon Industrial Park Kadima 60920 Israel Phone 972 98 91 24 41 Fax 972 98 91 24 45 technologies com info ecozone technologies com www ecozone ...