background image

15

REMOTE CONTROL

Mini Split Inverter

EDFM

1

2

3

4

5

TIMER ON 

TIMER OFF

(Off

Start 

Stop operation)

This feature is useful when you want to start the air 

conditioner before you wake up and stop it after you 

leave the house. 

Example:

To start the air conditioner 2 hours after setting, and 

stop it 5 hours after setting.

Press the TIMER ON button.

Press the TIMER ON button again  to display 2.0H on the 

TIMER ON display.

Press the TIMER OFF button.

Press the TIMER OFF button again to display 5.0H on the 

TIMER OFF display .

Wait for 3 seconds and the digital display area will show 

the temperature again

Stop

Start

2 hours later

after setting

5 hours later

after setting

Set

5

H

      TIMER ON/OFF

Содержание RG57A7/BGEF

Страница 1: ...EDFM OWNER SMANUAL REMOTE CONTROL Mini Split Inverter Thank you for purchasing this ecox product Before using this unit please read this owner s manual and retain it for future reference EDFM ...

Страница 2: ... THE REMOTE CONTROL REMOTE CONTROL SPECIFICATIONS FUNCTION BUTTONS INDICATORS ON LCD HOW TO USE THE BUTTONS AUTO OPERATION COOLING HEATING FAN OPERATION DEHUMIDIFYING OPERATION TIMER OPERATION EXAMPLE OF TIMER SETTING CONTENTS 5 3 6 10 9 11 10 12 10 13 ...

Страница 3: ...ght the air conditioner may not function properly Use curtains to prevent the sunlight from failing on the receiver If other electrical appliances react to the remote control either move these appliances or consult your local dealer Do not drop the remote control Handle with care Do not place heavy objects on the remote control or step on it Use the remote control within a distance of 8 meters 26 ...

Страница 4: ...emote control can be attached to a wall or pillar by using a remote control holder not supplied purchased separately Before installing the remote control check that the air conditioner receives the signals properly Install the remote control with two screws For installing or removing the remote control move it up or down in the holder The following may occur when the batteries have ran out of char...

Страница 5: ...n individual models All the functions described are accomplished by the indoor unit If the indoor unit does not have a feature there is no corresponding operation when pressing the button on the remote control PERFORMANCE FEATURE Do not mix old and new batteries or batteries of a different type Do not leave the batteries in the remote control if it is not going to be used for 2 or 3 months Dispose...

Страница 6: ...and save energy This function is available on COOL HEAT or AUTO mode only For more details see sleep operation in USER S MANUAL NOTE While the unit is running under SLEEP mode it would be cancelled if MODE FAN or ON OFF button is pressed TURBO Button Active Disable Turbo function Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time if...

Страница 7: ...temperature is less than 24ºC 75ºF If the set temperature is between 24ºC 75ºF and 30ºC 86ºF press the ECO button the fan speed will change to Auto the set temperature will remain unchanged NOTE Pressing the TURBO and SLEEP button modifying the mode or adjusting the set temperature to less than 24ºC 75ºF will stop ECO operation Under ECO operation the set temperature should be 24ºC 75ºF or more If...

Страница 8: ...for each press FOLLOW ME Button applicable to RG57A7 BGEF Push this button to initiate the Follow Me feature the remote control will sense the actual temperature at its location The remote control will send this signal to the indoor unit every 3 minutes until the Follow Me button is pressed again The function will cancel if no signal is received during a 7 minute interval LED Button Disable Active...

Страница 9: ...setting DisplayedinSleepModeoperation Notavailableforthisunit Notavailableforthisunit Indicatedthattheairconditioneris operatinginFollowmemode Fan speed indication Low speed Medium speed High speed Auto fan speed INDICATORS ON LCD Note All indicators shown in the figure are for the purpose of clear presentation But during the actual operation only the relative functional signs are shown on the dis...

Страница 10: ...ode is not comfortable for you the desired mode can be selected manually Ensure the unit is plugged in and power is available Press the MODE button to select COOL HEAT cooling heating models only or FAN mode Press the TEMP button to set the desired temperature The temperature can be set within a range 17ºC 30ºC 63ºF 86ºF in 1º increments Press the FAN button to select the fan speed in four steps A...

Страница 11: ... button to select DRY mode Press the TEMP button to set the desired temperature The temperature can be set within a range of 17ºC 30ºC 63ºF 86ºF in 1º increments Press the ON OFF button to start the air conditioner NOTE In the Dehumidifying mode you can not switch the fan speed It will be automatically controlled by the unit 1 2 3 3 1 2 FAN TIMER ON TIMER OFF TEMP SWING DIRECT SLEEP TURBO LED MODE...

Страница 12: ...ditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window To set the Auto off time Press the TIMER OFF button The remote control shows TIMER OFF the last Auto off setting time and the signal H will be shown on the LCD display area Now it is ready to reset the Auto off time to START the operation Push the TIMER O...

Страница 13: ... 5 9 0 9 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 and 24 1 2 3 EXAMPLE OF TIMER SETTING TIMER ON Auto on Operation The TIMER ON feature is useful when you want the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time Example To start the air conditioner in 6 hours Press the TIMER ON button the last setting of starting operat...

Страница 14: ...gain Now this function is activated COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF TIMER ON On Stop Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home Example To stop the air conditioner 2 hours after setting and start it again 10 hours after setting ...

Страница 15: ... the air conditioner 2 hours after setting and stop it 5 hours after setting Press theTIMER ON button Press theTIMER ON button again to display 2 0H on the TIMER ON display Press theTIMER OFF button Press theTIMER OFF button again to display 5 0H on the TIMER OFF display Wait for 3 seconds and the digital display area will show the temperature again Stop Start 2 hours later after setting 5 hours l...