EIHPTC

CEILING FLOOR TYPE

CAUTION 

 

Carry out the specified installation work after taking into 

account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling and 

causing accidents.

If the refrigerant leaks during installation, ventilate the area 

immediately.

Toxic gas may be produced if the refrigerant comes into the place 

contacting with fire.

The temperature of refrigerant circuit will be high, please keep 

the interconnection cable away from the copper tube.

After completing the installation work, check that the 

refrigerant does not leak.

Toxic gas may be produced if the refrigerant leaks into the room 

and comes into contact with a source of fire, such as a fan heater, 

stove or cooker.

Ground the air conditioner.

Do not connect the ground wire to gas or water pipes, lightning 

rod or a telephone ground wire. Inapropriate      grounding       may 

result in electric shocks.

Be sure to install an earth leakage breaker. 

Failure to install an earth leakage breaker may result in electric 

shocks.

Connect the outdoor unit wires , then connect the indoor unit 

wires.

You are not allowed to connect the air conditioner with the power 

supply until the wiring and piping is  done.

While following the instructions in this installation manual, 

install drain piping in order to ensure proper drainage and 

insulate piping in order to prevent condensation.

Improper drain piping may result in water leakage and property 

damage.

Install the indoor and outdoor units, power supply wiring 

and connecting wires should be at least 1 meter away from 

televisions or radios in order to prevent image interference or 

noise.

Depending on the radio waves, a distance of 1 meter may not be 

sufficient enough to eliminate the noise.

The appliance is not intended for use by young children or infirm 

persons without supervision.

Don't install the air conditioner in the following circumstance:

 There is petrolatum existing.

 There is salty air surrounding (Near the coast).

 There is caustic gas (The sulfide, for example) existing in the air 

(Near a hot spring).

 The Volt vibrates violently (In the factories).

 In buses or cabinets.

 In kitchen where it is full of oil gas.

 There is strong electromagnetic wave existing.

 There are inflammable materials or gas.

 There is acid or alkaline liquid evaporating.

 Other special conditions.

The appliance shall be installed in accordance with national 

wiring regulations.

Do not operate your air conditioner in a wet room such as a 

bathroom or laundry room.

An all-pole disconnection device which has at least 3mm 

clearances in all poles, and have a leakage current that may 

exceed 10mA, the residual current device (RCD) having a 

rated residual operating current not exceeding 30mA, and 

disconnection must be incorporated in the fixed wiring in 

accordance with the wiring rules.

INSTALLATION INFORMATION

2.

 To install properly, please read this "installation manual" at first.

 The air conditioner must be installed by qualified persons.

 When installing the indoor unit or its tubing, please follow this 

manual as strictly as possible.

 If the air conditioner is installed on a metal part of the building, 

it must be electrically insulated according to the relevant 

standards to electrical appliances.

 When all the installation work is finished, please turn on the 

power only after a thorough check.

 Regret for no further announcement if there is any change of 

this manual caused by product improvement.

INSTALLATION ORDER

 Select the location.

 Install the indoor unit.

 Install the outdoor unit.

 Install the connecting pipe.

 Connect the drain pipe.

 Wiring.

 Test operation.

Содержание EIHPTC

Страница 1: ...CEILING FLOOR TYPE Thank you for purchasing this ecox product Before using this machine please read this manual and retain it for future reference INSTALLATION MANUAL EIHPTC EIHPTC ...

Страница 2: ...ambient can lead to oxygen deficiency Use the attached accessories parts and specified parts or installation Otherwise it will cause the set to fall water leakage electrical shock and fire Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance shall not be i...

Страница 3: ...ter may not be sufficient enough to eliminate the noise Theapplianceisnotintendedforusebyyoungchildrenorinfirm persons without supervision Don t install the air conditioner in the following circumstance There is petrolatum existing There is salty air surrounding Near the coast There is caustic gas The sulfide for example existing in the air Near a hot spring The Volt vibrates violently In the fact...

Страница 4: ... air flow can reach throughout the room CAUTION Keep indoor unit outdoor unit power supply wiring and transmission wiring at least 1 meter away from televisions and radios This is to prevent image interference and noise in those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if 1 meter is kept QUANTITY SHAPE NAME 5 Owner s m...

Страница 5: ...o 45 50mm to prevent loose STEEL ROOF BEAM STRUCTRUE Install and use directly the supporting angle steel Fig 5 3 Roof beam Hanging screw bolts Ceiling Timber over the beam Fig 5 4 Fig 5 5 Steel bar Embedding screw bolt Pipe hanging and embedding screw bolt Blade shape insertion Slide insertion Fig 5 6 Fig 5 7 Hanging screw bolt Hanging bolts Supporting angle steel Fig 5 8 Side board Grille Hanging...

Страница 6: ...e the fan operating properly by putting the unit lengthwise along the wall or using a dust shield Refer to Fig 6 1 If possible do not install the unit where it is exposed to direct sunlight If necessary install a blind that does not interfere with the air flow During the heating mode the water drained off the outdoor unit The condensate should be well drained away by the drain hole to an appropria...

Страница 7: ...59 759 554 554 633 600 600 710 710 843 710 710 MODEL DIMENSIONS 36 48 60 36 24 18 Refer to Fig 6 5 Fig 6 6 REMARK Centrifugal fan type outdoor unit 3 Table 6 3 mm Fig 6 7 A B D E F H I J G C A 1394 1174 B 1338 1120 C 783 680 D 820 720 E 850 750 F 568 475 G 398 300 H 574 430 I 342 265 J 463 1394 1338 783 820 850 568 398 574 342 463 1338 783 820 850 568 398 574 342 463 393 MODEL 36 48 60 18 1174 112...

Страница 8: ... fan position NOTE Keep in mind that fan unit weight is aprox 30kg the unit as well as relevantequipmentcoveredwiththevinylcoverduringinstallation work Air inlet modification To change air inlet is only necessary to interchange the indicated panels position Both panels use screws to be fixed to unit chassis To change air outlet is necessary to interchange panels too Fan outlet panel is attached to...

Страница 9: ...iling can resist the Outdoor unit weight indicated in specification label plate 2 1 Sling Bolt Suspension Bracket Fig 6 17 INSTALLTHE CONNECTING PIPE 7 Check whether the height drop between the indoor unit and outdoor unit the length of refrigerant pipe and the number of the bends meet the following requirements The number of the bends less than 15 Table 7 1 Model 12K 18K 24K 30K 42K 12K 18K 24K 3...

Страница 10: ... expel the air with a vacuum pump for details Open the stop values of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit in fluent flow Check the leakage Check all the joints with the leak detector or soap water Cover the joints of the connecting pipe with the soundproof insulating sheath fittings and bind it well with the tapes to prevent leakage 2 1 3 ...

Страница 11: ... 1 2 3 2 1 Make sure to tighten the cap securely For the tightening torque refer to the table below CAUTION Always use a charge hose for service port connection After tightening the cap check that no refrigerant leaks arepresent Fig 7 7 service port cap maintenance nut hexagon hole shaft seal 1 Using the vacuum pump Loosen and remove the maintenance nuts of stop valves A and B and connect the char...

Страница 12: ... orifice in the outdoorunit orifice in the outdoorunit orifice in the indoorunit orifice in the indoorunit orifice in the indoorunit orifice in the indoorunit The Table above refer to the liquid tube The number of bends is up to the length of the max height drop Usually for each 10m need a bend CONNECTTHE DRAIN PIPE 8 Install the drainpipe of the indoor unit The outlet has PTI screw bread Please u...

Страница 13: ...eparatepowersupplywithrated voltage The external power supply to the air conditioner should have ground wiring which is linked to the ground wiring of the indoor and outdoor unit The wiring work should be done by qualified persons according to circuit drawing An all pole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of...

Страница 14: ...the power According to the user s requirement install the remote controller frame where the remote controller s signal can reach the indoor unit smoothly Test operation Set the air conditioner under the mode of COOLING with the remote controller and check the following points If there is any malfunction please resolve it according to the chapter Troubleshooting in the Owner s Manual 1 The indoor u...

Страница 15: ...42 48 208 240V 1Phase 20 16 12 18 208 240V 1Phase 208 240V 1Phase 208 240V 1Phase 208 240V 1Phase MODEL POWER CIRCUIT BREAKER FUSE A PHASE FREQUENCY AND VOLT 6 3 0 3 6 3 0 3 42 60 42 60 380 420V 25 20 25 20 40 25 45 35 208 240V 3Phase 380 420V 3Phase 3Phase 208 240V 3Phase 20 16 40 25 50 30 60 45 60 50 MODEL POWER CIRCUIT BREAKER FUSE A PHASE FREQUENCY AND VOLT 0 6 4 2 8 1 30 36 42 48 208 240V 208...

Страница 16: ...g Indoor Unit Outdoor Unit Power supply Ground the air conditioner properly in case to affect its anti interference function Power supply Switch Fuse Available locally CAUTION A disconnection device having an air gap contact separation in all active conductors should be incorporated in the fixed wiring according to the National Wiring Regulation When wiring please choose the corresponding chart or...

Страница 17: ...17 EIHPTC CEILING FLOOR TYPE ...

Страница 18: ......

Отзывы: