background image

13

The wind gust reading will be the max wind speed in

the past 28s.

When the wind speed is lower than 5m/s,the dispersion

of wind direction will increase.

4.2 Measurement Specification

Measurement Range

Accuracy

Resolution

Wind speed

0m/s to

40m/s

<10m/s,

±

0.5m/s;

10m/s,

±

5%

0.1m/s

Wind

direction

0

°

to

359

°

<2m/s,

±

10

°

;

2m/s,

±

7

°

Temperature

-40

°

C

to 60

°

C

±

0.3

°

C (

±

0.6

°

F)

0.1

°

C (

±

0.2

°

F)

Humidity

1 to 99%

±3.5%

1%

Light

0 to

200Klux

±15%

0.1Klux

UVI

1 to 15

±2

1

Rain

0 to 9999

TBA

0.1mm

Содержание WS90

Страница 1: ...3 1 2 Features 4 2 Overview 5 3 Setup Guide 6 3 1 Install batteries in sensor package 6 3 2 Mount ultrasonic anemometer with piezoelectric assembly 8 3 2 1 Before you mount 8 3 2 2 Mounting 9 3 2 3 Reset Button and Transmitter LED 12 4 Specification 12 4 1 Transmission between gateway and sensor 12 4 2 Measurement Specification 13 4 3 Power consumption 14 5 Warranty Information 14 ...

Страница 2: ...ice QR perleggi il manuale italiano e conservalo perReferenza futura Quick start APP manuals Compatibility table firm ware https s ecowitt com MP7YJJ Help Our product is continuously changing and improving particularly online services and associated applications To download the latest manual and additional help please contact our technical support team support ecowitt com support eu ecowitt net EU...

Страница 3: ...l need 2 AA size battery for the ultrasonic anemometer which is primarily for startup and backup power purpose After setup and during normal operation the unit is getting its power from solar cell Note There s a built in heat plate in the 7 in 1 sensor package body if the lowesttemperature at your place is below 3 C or 26 6 F and the weather ismostly snowy or rainy then you may need to activate th...

Страница 4: ...n gauge Ultrasonic anemometer start wind speed 0 3m s Temperature Humidity Solar light intensity and UV index Waterproof IPX5 Heater and additional power supply Note There s a built in thermostat inside the anemometer sensorto control the power supply for the heat plate which will automatically turnon below 0 30 and automatically turn off above 10 50 ...

Страница 5: ...5 2 Overview Figure 1 Sensor package assembly components ...

Страница 6: ...le 1 Sensor package assembly component list 3 Setup Guide 3 1 Install batteries in sensor package Open the battery compartment with a screwdriver and insert 2 AA batteries in the battery compartment and press Reset button the LED indicator on the back of the sensor package item 4 will turn on for 3 seconds and then flash once every 8 8 seconds indicating sensor data transmission If you did not pay...

Страница 7: ...AA backup battery the system might not start up properly So you can always make a system reset by press the Reset button Figure 2 Battery installation diagram Note Please make sure the battery is inserted correctly for its polarity as the system needs its initial power from this backup battery to start up the system before solar panel charges ...

Страница 8: ... weather conditions as when heater activated the trapped heat inside will warm up internally and alkaline batteries are extremely susceptible to leakage when temperature is over certain limits 3 2 Mount ultrasonic anemometer with piezoelectric assembly 3 2 1 Before you mount Before installing your outdoor sensor in the permanent location we recommend operating the device for one week in a temporar...

Страница 9: ...tach a pole not included to a permanent structure and then attach the sensor package to it see Figure 3 The install hole will accommodate a pole diameter of 1 0 inch pole not included Figure 3 Sensor package mounting diagram 6 1 ...

Страница 10: ... is vertical or very close to it Use a level as needed 1 If optional extension cord is added connect the cord to the connector and insert the USB port into the AC adaptor as Figure 4 show Figure 4 Sensor package mounting diagram 6 2 ...

Страница 11: ...o SOUTH as its solar panel is a rounded type and it is orientation free for its charging capability Make sure the mounting tube for the sensor package is installed vertically use a level at 90 degree offsets around the tube Adjust the mounting pipe as necessary Next also make sure the mounting of the anemometer body on the pipe is level If it is not wind direction and speed readings may not operat...

Страница 12: ... let go The LED should then resume as normal flashing approximately once every 8 8 seconds 4 Specification 4 1 Transmission between gateway and sensor Transmission distance in open field 150 m 500 ft depend on environment RF frequency 433 868 915 920 MHz depending on location Sensor reporting interval 8 8 seconds Note The wind speed is detected by every 2s The wind speed reading will be a real tim...

Страница 13: ...d direction will increase 4 2 Measurement Specification Measurement Range Accuracy Resolution Wind speed 0m s to 40m s 10m s 0 5m s 10m s 5 0 1m s Wind direction 0 to 359 2m s 10 2m s 7 1 Temperature 40 C to 60 C 0 3 C 0 6 F 0 1 C 0 2 F Humidity 1 to 99 3 5 1 Light 0 to 200Klux 15 0 1Klux UVI 1 to 15 2 1 Rain 0 to 9999 TBA 0 1mm ...

Страница 14: ...al error or printing error or the consequences thereof All trademarks and patents are recognized We provide a 1 year limited warranty on this product against manufacturing defects or defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the...

Страница 15: ...installation or removal from a fixed installation normal set up or adjustments or claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances ...

Отзывы: