"ECOWITT WH0310" - водонепроницаемый датчик температуры и влажности. Загружайте бесплатное руководство пользователя на нашем сайте, чтобы быстро и легко настроить ваш умный датчик. Не забудьте скачать руководство с manualshive.com.
1
Wireless Weather Station with
Multi-channel Temperature Sensor
Model: WH0310
Страница 1: ...1 Wireless Weather Station with Multi channel Temperature Sensor Model WH0310 ...
Страница 2: ...Sensor Operation Verification 13 3 Wireless Sensor Installation 14 3 1 Mounting with Zip Tie 14 4 Console Operation 15 4 1 ABS REL Barometer display 15 4 2 Setting Mode 15 4 3 Pressure Tendency Indicator 17 4 4 24H 7days History Graph 18 4 5 Weather Forecast Algorithm 19 4 6 RF channels setting and sensor resynchronization 20 4 7 High Low Record 21 4 7 1 Check latest 24 hours High Low record 21 ...
Страница 3: ...k history High Low record 22 4 8 Best Practices for Wireless Communication 22 5 Specifications 25 5 1 Wireless Specifications 25 5 2 Measurement Specifications 26 5 3 Power Consumption 26 6 Warranty Information 27 ...
Страница 4: ...e Also supports to add max three temperature sensors additional two sensors sold separately to monitor multi places The following user guide provides step by step instructions for installation operation and troubleshooting 2 Getting Started Note The power up sequence can be performed in the order shown in this section insert batteries in the remote transmitter s first display console secondly ...
Страница 5: ...nual 2 2 Recommend Tools Hammer for hanging remote thermometer transmitter 2 3 Thermometer Sensor Set Up We recommend fresh alkaline batteries for outdoor temperature ranges between 4 F and 140 F 20 60 and fresh lithium batteries for outdoor temperature ranges between 40 F and 140 F 40 60 ...
Страница 6: ... Remove the battery door on the back of the sensor by sliding the compartment door down as shown in Figure 1 Figure 1 1 Wireless transmitter LED 2 1 2 3 RF Channels 3 AA Battery 4 Battery Compartment Cover ...
Страница 7: ... flashes the sensor is transmitting data 5 Close the battery door Repeat for the additional remote transmitters sold separately verifying each remote is on a different channel 2 4 Display Console Set Up 1 Move the remote thermometer s about 5 to 10 away from the display console if the sensor is too close it may not be received by the display console 2 Remove the battery door on the back of the ...
Страница 8: ...8 display as shown in Figure 2 Insert one AA alkaline or lithium rechargeable battery in the back of the display console Figure 2 ...
Страница 9: ...ons as a or increase button while in setup mode 2 CH Enable or disable the Cycle Mode press once Cycle between display of RF channels sensor data 3 LIGHT Enable disable the screen backlight press once return from setup mode to display mode 4 Hanging hole 5 Battery Compartment 6 Battery Compartment door ...
Страница 10: ...en ABS REL barometer press once Used to enter setup mode hold for 2s also functions as a next button in setup mode All of the LCD segments will light up for a few seconds to verify all segments are operating properly 3 Replace the battery door and fold out the desk stand and place the console in the upright position The console will instantly display indoor ...
Страница 11: ...ture and humidity The remote temperature will update on the display within a few minutes While in the search mode the reception search icon flash If the remote does not update please contact the customer service ...
Страница 12: ...12 2 4 1 Display Console Layout Figure 3 ...
Страница 13: ...acy is 1 F Please allow about 30 minutes for both sensors to stabilize 1 Indoor temperature 2 Weather forecast 3 Barometric pressure changing trend 4 Outdoor multi channel temperature 5 Indoor humidity 6 ABS REL barometric pressure 7 Pressure tendency indicator 8 24H 7days history graph for ABS barometric pressure 9 Cycle Mode icon RF channel number 1 0 Outdoor multi channel temperature 24H high l...
Страница 14: ...the remote sensor in a shaded area Direct sunlight and radiant heat sources will result in inaccurate temperature readings Although the sensor is weather resistant it is best to mount in a well protected area such as under an eve 3 1 Mounting with Zip Tie Figure 4 ...
Страница 15: ...n be exited at any time by either pressing the LIGHT button or waiting for the 30 second time out to take effect 4 1 ABS REL Barometer display In normal mode press the MODE button once to switch the display of barometer ABS REL 4 2 Setting Mode In normal mode hold the MODE button for 2 seconds to enter setting mode The following items can be set Temperature display unit C F ...
Страница 16: ...225 0 900 1mmHg Note To calibrate the barometric pressure we recommend you to go to this link to check the operation http www ecowitt com news 102 html Use the MODE button to move to the next settings Press the or button to change the settings for the selected item Press the LIGHT button can return to normal mode ...
Страница 17: ...hange tendency updating every 60 second is reflected by the scale indicator located under pressure display digits Usually this is an indicator of weather change when pressure is going in upward direction it normally mean weather is getting better ...
Страница 18: ...18 4 4 24H 7days History Graph Figure Last 24H graph Figure Last 7days graph ...
Страница 19: ...orecast comparison between past 24 hour average against past 30 day average pressure Pressure Difference Weather status 4hpa Sunny 0 5hpa to 3 5hpa Partly cloudy 3 5hpa to 1hpa Cloudy 4hpa Rainy 2 Storm forecast If there is a sudden pressure decrease due to storm approaching reason weather forecast will having Rainy displayed and flashing This is to tell there might be a storm approaching ...
Страница 20: ...on with the channel number different channel sensor s data will be toggled for display on LCD Press CH button once can exit the cycle mode and display the current channel sensor data all the time CH1 CH2 CH3 Cycle Mode If the remote sensor signal is lost dashes will display on the console In cycle mode hold the CH button for 2 seconds will re register all the channels sensors ...
Страница 21: ...te If you only purchased one multi channel temperature sensor the other two channels will display You can cancel the cycle mode to make the console only display the current channel data 4 7 High Low Record 4 7 1 Check latest 24 hours High Low record In normal mode the console will display the latest 24 hours High Low record for outdoor multi channel temperature ...
Страница 22: ...cycle mode hold the button for 2s can clear the high low record for all the channels sensors In non cycle mode hold the button for 2s can clear the high low record for the current channel sensor 4 8 Best Practices for Wireless Communication Note To ensure proper communication mount the remote sensor on a vertical surface such as a wall Do not lay the sensor flat Wireless communication is susceptib...
Страница 23: ...d communication is intermittent try turning off these other devices for troubleshooting purposes You may need to relocate the transmitters or receivers to avoid intermittent communication 3 Line of Sight Rating This device is rated at 300 feet line of sight no interference barriers or walls but typically you will get 100 feet maximum under most real world installations which include passing throug...
Страница 24: ...ear line of sight The following is a table of reception loss vs the transmission medium Each wall or obstruction decreases the transmission range by the factor shown below Medium RF Signal Strength Reduction Glass untreated 5 15 Plastics 10 15 Wood 10 40 Brick 10 40 Concrete 40 80 Metal 90 100 ...
Страница 25: ...nsmission in open areas 300 feet 100 feet under most conditions Frequency 433 MHz Sensor Update Rate 60 seconds Weather forecast update rate 10 minutes based on the barometric pressure changing Barometric pressure trend arrow update rate 60 seconds compared with last 3H value ...
Страница 26: ...aline or Lithium batteries not included Remote sensor 1 x AA 1 5V Alkaline or Lithium batteries not included Battery life About 2 years for base station Measurement Range Accuracy Resolution Indoor Temperature 32 to 122 F 0 to 50 1 F 0 1 F Indoor Humidity 10 99 5 1 Outdoor Temperature 40 to 140 F 40 to 60 1 F 0 1 F Barometric Pressure 300 0hPa 1200 0h pa 3hPa 0 1hPa ...
Страница 27: ...r climates less than 4 F 6 Warranty Information We disclaim any responsibility for any technical error or printing error or their consequences All trademarks and patents are recognized We provide a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased ...
Страница 28: ...ination and service procedures This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances ...