Service Information
ECOWATER
S Y S T E
M S
17
NEUTRALIZING FILTER -- CHECKING THE MIN-
ERAL LEVEL IN THE TANK:
As explained on page
14, the mineral dissolves in the water to neutralize
the acid. How fast is dissolves depends on how
much water you household uses and the pH of the
water.
Every few months you should measure the mineral
bed level in the tank. Always add new mineral before
the tank is empty. To measure, do the following.
1. Refer to page 12 and initiate the RECHARGE
NOW feature.
2. When water starts to run from the drain hose, put
the plumbing bypass valve(s) in bypass posi-
tion...see figure 7, page 9, TO DEPRESSURIZE
THE FILTER.
3. Unplug the transformer at the wall outlet.
4. Remove the controller cover.
5. Disconnect the inlet and outlet copper tubes...see
page 8.
6. Remove the valve assembly from the mineral
tank...page 5.
7. Remove the top distributor and four o--ring
seals...page 5.
FIGURE 14
SUGGESTED
FREEBOARD
ETF2100PF10
15”
ETF2100PF12
16”
8. Use a yard stick or steel tape measure to find the
distance down to the top of the mineral bed...FI-
GURE 14. If 15”below the suggested freeboard,
add more neutralite material.
9. Use a funnel to add more mineral, if needed.
10. Flush all mineral from the tank top opening.
Then replace the distributor and four o--ring
seals...figure 1, page 5.
11. Do the following steps to return the filter to ser-
vice.
-- step 4, page 5
-- step 1b and 1c, page 8
-- step 8, page 9, if hose was disconnected
-- steps 9 through 12, page 10.
Note:
After electrical power is applied, see page 11
if the time display is flashing.
-- initiate RECHARGE NOW feature, see page 12.
TASTE AND ODOR FILTER -- REPLACING THE
ACTIVATED CARBON MINERAL BED (SEE PAGE
14):
When the filter no longer removes tastes and/or
odors from the water, the activated carbon bed must
be replaced. To replace the bed:
1. Do steps 1 through 7, above left.
2. Carefully lay the filter tank over. Pull the standpipe
and bottom distributor from the mineral bed.
3. Dump the contents of the tank into a suitable con-
tainer.
4. Stand the tank upright and replace the bottom dis-
tributor and standpipe.
5. Add the required amounts of gravel, filter sand,
and activated carbon mineral...see specifications,
page 4.
6. Do steps 10 and 11, above.
Содержание ETF2100 PF
Страница 15: ...Filter Operation ECOWATER S Y S T E M S 3 15 WATER FLOW PATHS FIGURE 11 SERVICE CYCLE FIGURE 12 BACKWASH CYCLE ...
Страница 16: ...Filter Operation ECOWATER S Y S T E M S 16 FIGURE 13 FAST RINSE CYCLE ...
Страница 20: ...Repair Parts ECOWATER S Y S T E M S 3 20 18 20 19 4 1 2 3 9 8 10 11 12 13 14 15 16 17 6 7 5 ...
Страница 24: ...PRINTED IN U S A Part No 7217933 02 2000 EcoWater Systems P O Box 64420 St Paul MN 55164 9888 651 739 5330 ...