17
ECOWATER
S Y S T E M S
Features / Options (Filters)
ADJUSTABLE BRINE DRAW
1
. Press and hold the SELECT button, until the dis-
play shows “000 - -“.
2
. Press the SELECT button twice and “dr” will
appear in the display, followed by the current brine
draw time, in minutes, flashing.
3
. Press the
á
UP or
â
DOWN buttons to set the
brine draw time, from 0 to 255 minutes.
4
. Press the SELECT button several times to return
advance through the remaining screens and return
to the normal run (time of day) display.
12 OR 24 HOUR CLOCK
The timer has been factory preset to display a 12 hour
(AM/PM) clock. If you prefer, you may change this to
display a 24 hour clock.
1
. Press and hold the SELECT button, until the dis-
play shows “000 - -“.
2
. Press the SELECT button three times and “12 hr”
will flash in the display.
FIG. 32
ADJUSTABLE BACKWASH TIME
1
. Press and hold the SELECT button until “000 - -”
shows in the display.
2
. Press the SELECT button four times and “bA-” will
appear in the display, followed by the current back-
wash time, in minutes, flashing.
3
. Use the
á
UP or
â
DOWN buttons to set the
number of minutes desired for backwash, from 0 to
99 minutes.
4
. Press the SELECT button several times to return
advance through the remaining screens and return
to the normal run (time of day) display.
ADJUSTABLE FAST RINSE TIME
1
. Press and hold the SELECT button until “000 - -”
shows in the display.
2
. Press the SELECT button five times and “Fr-” will
appear in the display, followed by the current fast
rinse time, in minutes, flashing.
FIG. 34
FIG. 35
3
. Use the
á
UP or
â
DOWN buttons to set the
number of minutes desired for fast rinse, from 0 to
99 minutes.
6
. Press the SELECT button several times to return
advance through the remaining screens and return
to the normal run (time of day) display.
FIG. 33
3
. Use the
á
UP button to change to a 24 hour clock
display.
4
. Press the SELECT button several times to
advance through the remaining screens and return
to the normal operation (time of day) display.
5
. To change back to a 12 hour clock, follow Steps 1
through 4, above, except use the
â
DOWN button
in Step 3.
ECOWATER
S Y S T E M S
Features / Options (All Models)
AUXILIARY OUTPUT CONTROL
The electronic controller’s auxiliary output may be
used to operate various types of external equipment,
such as a chlorine generator or chemical feeder. It
provides a 24V DC, up to 500 mA, current from termi-
nal J4 on the electronic control board (see Schematic
on the next page). The table on the next page
explains the choices available for when the auxiliary
output will be on during various portions of the
recharge cycle.
continued on next page