15
ECOWATER
S Y S T E M S
Features / Options (Softeners)
FIG. 23
FIG. 25
SET CAPACITY
The electronic controller determines this number,
based on the initial timer programming.
Setting Softening
Capacity
Salt Use
Water Use
CAP 1
Lowest
Most
salt efficient
Regenerates
more often
CAP 2
Medium
Medium
Medium
CAP 3
Highest
Uses
most salt
Regenerates
less often
3
. Press the SELECT button several times to return
advance through the remaining screens and return
to the normal run (time of day) display.
If you want to change the capacity, do the following:
1
. Press and hold for 3 seconds the SELECT button,
until the display shows “000 - -“.
2
. Once in this display, press the SELECT button
once and “CAP” will show in the display.
3
. Use the
á
UP button to change to a 24 hour clock
display.
4
. Press the SELECT button several times to
advance through the remaining screens and return
to the normal operation (time of day) display.
5
. To change back to a 12 hour clock, follow Steps 1
through 4, above, except use the
â
DOWN button
in Step 3.
ADJUST BACKWASH AND RINSE TIME
The timer can be changed to allow different back-
wash and fast rinse times, if so desired. Each of
these can be adjusted from 0 to 99 minutes.
1
. Press and hold the SELECT button until “000 - -”
shows in the display.
2
. Press the SELECT button four times and “bA-” will
appear in the display, followed by the current back-
wash time, in minutes, flashing.
3
. Use the
á
UP or
â
DOWN buttons to set the
number of minutes desired for backwash.
4
. Press the SELECT button again and “Fr-” will
appear in the display, followed by the current fast
rinse time, in minutes, flashing.
5
. Use the
á
UP or
â
DOWN buttons to set the
number of minutes desired for fast rinse.
6
. Press the SELECT button several times to return
advance through the remaining screens and return
to the normal run (time of day) display.
3
. Press the
á
UP or
â
DOWN buttons to set the
capacity number.
4
. Press the SELECT button several times to return
advance through the remaining screens and return
to the normal run (time of day) display.
VIEW DAYS TO RECHARGE
This view-only display shows the number of days the
softener will run before the next recharge. This dis-
play will not be available if Hardness was set to OFF
(as described on the previous page).
1
. Press and hold the SELECT button, until the dis-
play shows “000 - -“.
2
. Press the SELECT button twice and “Recharge”
will show in the display.
12 OR 24 HOUR CLOCK
The timer has been factory preset to display a 12 hour
(AM/PM) clock. If you prefer, you may change this to
display a 24 hour clock.
1
. Press and hold the SELECT button, until the dis-
play shows “000 - -“.
2
. Press the SELECT button three times and “12 hr”
will flash in the display.
FIG. 24
FIG. 26