background image

7301805 (Rev. A 3/12/08)

EcoWater Systems LLC

P.O. Box 64420, St. Paul, MN  55164-0420

How to install, operate and maintain your

EcoWater Systems

Automatic Sediment Filter

Model EASF1

OWNER’S MANUAL

Содержание EASF1

Страница 1: ...7301805 Rev A 3 12 08 EcoWater Systems LLC P O Box 64420 St Paul MN 55164 0420 How to install operate and maintain your EcoWater Systems Automatic Sediment Filter Model EASF1 OWNER S MANUAL...

Страница 2: ...ctrical and electronic equipment to be disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from re...

Страница 3: ...nt Filter is operated at water pressures not exceeding 100 psi and at water temperatures not exceeding 120 F provided further that the Automatic Sediment Filter is not subject to abuse misuse alterati...

Страница 4: ...d complete in one carton Remove all items from the shipping carton and check against the packing list below Packing List Filter Assembly Dimensions 5 1 4 15 4 1 8 10 FIG 2 Inlet Outlet 1 NPT threaded...

Страница 5: ...is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an electronic con...

Страница 6: ...le the faceplate may need to be reversed turned around to face the opposite direc tion so that it does not end up against a wall or other obstruction This can be done either before or after the filter...

Страница 7: ...of Massachusetts The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment...

Страница 8: ...compression fittings NOTE If your installation will use the mounting brack et position it correctly around the ASF before installing inlet and outlet fittings The bracket can not be put on after the i...

Страница 9: ...before installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully tur...

Страница 10: ...ose Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Страница 11: ...AC ADAPTOR not included An optional AC adaptor P N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 6 feet of wire One end plugs into...

Страница 12: ...t for at least 2 seconds When the 2 digit display changes to show moving dashes See Figure 20 release the CLEAN button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence ta...

Страница 13: ...display Each press increases the number of days by 1 When the number passes 30 it goes back to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic...

Страница 14: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...

Страница 15: ...sole noid seat requires cleaning use the following procedure 1 Before shutting off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main ho...

Страница 16: ...320 O Ring Valve 2 req 15 7301601 Battery 9 Volt 16 7298387 Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7...

Отзывы: