Operating manual ВІСТ.418266.006-03 НЕ
29
“DER query”
frame format – the data display system to the detecting unit
D7 D6 D5 D4 D3 D2 D1 D0
0
1
0
1
0
1
0
1 Byte 55h
–
start-of-frame character
Byte AAh
1
0
1
0
1
0
1
0
0
0
0
0
А3
А2
А1
А0
D7...D4
–
“D
E
R query”
frame code
D3...D0
–
detecting unit address *
* -
0Fh
address – broadcast
address. All detecting units respond to the query with this address.
“Current DER”
frame format – the detecting unit to the data display system
D7 D6 D5 D4 D3 D2 D1 D0
0
1
0
1
0
1
0
1 Byte 55h - start-of-frame character
Byte AAh
1
0
1
0
1
0
1
0
0
0
0
1
А3
А2
А1
А0
D7...D4 -
“Current D
E
R”
frame code
D3...D0 - detecting unit address
DER0 (low byte)
DER,
fixed point number,
Least significant bit (LSB) = 0.01
µSv/h
DER1
DER2
DER3 (high byte)
Byte
Statistical error of measurement
D7
0
0
0
0
D2 D1 D0
D0,D1
–
self-testing results of the
detecting unit
D0=1
–
failure of the high sensitivity
detector
D1=1
–
failure of the low sensitivity
detector
Reliable measurement result character
D2=0
–
result is reliable
D2=1
–
result is not reliable *
D7=0
–
LSB DER = 0,01
µSv/h
D7=1
–
LSB DER = 0,1
µSv/h
control
arithmetical checksum with a carry
* - measurement result is accepted as not reliable if the statistical error of measurement exceeds maximum permissible
error of measurement
Содержание BDBG-09
Страница 1: ...BDBG 09 DETECTING UNIT OF GAMMA RADIATION Operating manual...