OPERATING PRINCIPLE
3.1
3.1.1
Expected use
The 60 series you bought was designed and produced in order to work on flat ground, of maximum slope of 15°. The work
potential changes depending on the assembled cutting surface.
Type of cutting surface
Expected use
BT
Trimming and cutting grass/brambles/scrubs, even in the presence of debris.
DCS
Cutting grass/brambles/scrubs on untilled land and underwood, particularly suitable for finishings and cutting operations on
grounds with debris.
MC
Cutting medium size grass and scrubs with good grinding of the cut material.
TRL
Cutting grass in a meadow or garden, particularly suitable for not excessively high grass, resulting in good finishings.
TRT
Cutting medium- and large-size grass/brambles/scrubs on untilled land and underwood, in extreme work conditions.
SIZE
3.2
Size
Model
Length (mm)
Width (mm)
Height (mm)
BT 60
1600
580
970
DCS 60
1600
630
970
DCS 60 Traction
1600
580
970
MC 60
1850
580
970
TRL 60
1800
580
1020
TRT 60
1800
580
1020
TRT 60 Pro
1800
580
1020
Table 3-1: Size
ENVIRONMENTAL CONDITIONS
3.3
The machine does not require any particular environmental conditions. It can work on dry grass, but also on wet grass, paying
attention to adjust the cutting waste opening to the maximum width possible, in order to avoid jamming the cutting surface,
which may result in engine fatigue.
In the presence of high grass, it is possible to facilitate the penetration of the
grass inside the cutting surface by removing the wall on the front of the cutting
surface (Figura 3-8 No.1) removing the three clamp screws. Without this wall
the machine may throw objects, therefore KEEP PEOPLE, ANIMALS OR THINGS
AT A MINIMUM DISTANCE OF 15 METRES.
Figure 3-8: Particular TRL cutting surface opening
LIGHTING
3.4
The machine was designed and produced to work outside with natural light. In case of night time work, make sure good artificial
lighting is present, equal to at least 150 lux (UNI EN 12646-2:2008).
VIBRATIONS
3.5
Operating conditions:
Engine rotation speed during tests: 3000 rpm.
60 series
Aeq
X 1.6 m/s²
Y 2.2 m/s²
Z 4.1 m/s²
NOISE EMISSION
3.6
Pondered equivalent continuous acoustic pressure level A in workplaces is the following:
60 series
96 - 98 dB(A)
Any other phonometric measurements in workplaces should be performed in compliance with the regulations in force in the
country where the machine is used.