background image

User information:

The boiler

An EcoTec MiniQ is designed for firing with pellets. 
Wood burning is not possible due to the design of 
the boiler.

Combustion 

The combustion process in the boiler is 
controlled by an external pellet burner. 
The burner must be installed by an au-
thorised installation engineer, to ensure 
optimum set-up of the combustion 
process. A correctly set-up burner yields 
better economy and less impact on the 
environment.
See the burner manual for installation, 
setting and maintenance information.

Convection

The flue gases in the boiler are cooled 
by the tubes running vertically down 
into the firebox, after which they pass 
out via the flue pipe.

Содержание MiniQ

Страница 1: ...5 kW Mini Q r en laddpanna Pannan anv nds i system med en ackumulatortank N r solpaneler ansluts g rs det mot en ackumulator tank d r det av sol eller pelletspannan uppv rmda vattnet lagras Den kom vi...

Страница 2: ...ulation cm 5 mineral wool Fuel type Wood pellets Max working pressure MPa 0 25 Max water temperature C 95 Chimney connection mm 130 130 A mm 480 480 B mm 855 855 C mm 845 895 D mm 905 955 E mm 380 380...

Страница 3: ...in the accumulator tank EcoTec MiniQ holds just 55 litres of water ensur ing minimal losses during downtime 1 The boiler s rear plate 2 Drain valve 3 Riser connection 4 Chimney connection 5 Return wa...

Страница 4: ...er The burner must be installed by an au thorised installation engineer to ensure optimum set up of the combustion process A correctly set up burner yields better economy and less impact on the enviro...

Страница 5: ...mpanying flue brush into the tubes and use it to scrape off all the soot Brush soot off the boiler walls and any other areas where it may accumulate Finish by emptying the ash drawer into a non flamma...

Страница 6: ...f 10 15 Pa in the boiler to achieve a good function The chimney should be at least 120 mm in diameter The flue pipe connection must have a damper Connection Pipe installation must be carried out in ac...

Страница 7: ...ust always be connected to an expan sion vessel With an open system the volume must be 5 of the system volume and with a sealed system 10 Safety valve The system must always be fitted with a safety va...

Страница 8: ...nd constant development We manufacture burners with an output between 7 kW and 300 kW We are confident that we can offer you the best products on the market and a reduction in your heating costs We re...