24. TECHNICAL SPECIFICATIONS
AC INPUT
Input voltage:
400VAC (3 phase without neutral) ±
10%
Input frequency:
50Hz
Power factor:
Rated output load PF ≥ 0.99
Connection value:
3 x 50A
(With a lower available capacity,
the charger can be set lower by
software)
RCD:
Type B
Input under voltage protection:
255V ±5V
Input overvoltage protection:
535V ±5V
Input Power Derating:
260V ±5V<Vin<304V±5V,
Linear power derating from 100% to
50%
DC OUTPUT
Output power:
1 - 30 kW
Constant power range:
30KW@400-500V
Output voltage range:
150~500V
Output current range:
0~80A
Output overvoltage protection:
510±5V
Output under voltage alarm:
140V±2V
Voltage stabilized accuracy:
≤±0.5%
Max. startup overshoot:
≤±1%
Current stabilized accuracy:
≤±1%
Startup Time:
Normally 3s ≤ t ≤ 8s
Efficiency:
>96%
OPERATING ENVIRONMENT
Operating temperature:
-30°C ~ 70°C, derating from 55°C
Overtemperature protection:
On temperature >70°C±4°C or
<-40°C±4°C, charger will shut down
automatically