background image

MANUAL for INSTALLATION and OPERATION of

ALBA 15KW

Содержание ALBA 15 kW

Страница 1: ...MANUAL for INSTALLATION and OPERATION of ALBA 15KW ...

Страница 2: ...TALLATION SCHEMES optional 9 3 7 REAR END OF THE EXHAUST GAS PIPE 10 3 8 CONNECTION TO THE ELECTRICAL POWER SUPPLY 10 4 0 USAGE 11 4 1 SAFETY PRECAUTIONS 11 4 2 FUELS 11 4 3 TECHNICAL SPECIFICATIONS 11 4 4 INSTALLATION 12 4 5 DISPLAY OF THE CONTROL PANEL 12 4 6 EXPLANATION OF THE CONTROL PANEL 12 5 0 PELLETS 17 5 1 STORAGE OF PELLETS 17 5 2 POURING THE PELLETS 17 6 0 CLEANING AND MAINTENANCE 18 6 ...

Страница 3: ... a statement which states that the pellet stove is connected according to all applicable standards and that the staff takes over the complete responsibility for its installation 3 It is important to observe all applicable national laws of the country where the product is to be installed 4 The manufacturer does not bear any responsibility if the above stated obligations are not observed 5 The Instr...

Страница 4: ...t Check if there are difficulties while turning the product on after a long period of non operation see chapter 6 0 The pellet stove is designed to work even in extreme weather conditions however in case of strong wind or frosty conditions the safety systems might trigger on and shut the pellet stove off In such case the user should contact the authorized service It is not advisable to disable or ...

Страница 5: ... Suitable for central space heating Mantle heat exchanger The hearth of the pellet stove is made of very thick cold rolled metal sheet as well as a supporting structure which is coated with high temperature and high quality powder like color The upper part the lower part and the burner are made of a special metal sheet The inner part of the burner is coated with double metal sheet which guarantees...

Страница 6: ...ER N ASH DRAWER V CONTROL PANEL I DOUBLE METAL SHEET OF THE BURNER S PELLET RESERVOIR L BURNER D PIPE CLEANING LEVER P ELECTRIC POWER SUPPLY SOCKET F CERAMIC GLASS R SIDE COLORED METAL SHEET 2 4 Technical data and dimensions ...

Страница 7: ...is very important as well as the proper connection of the exhaust gas system and that the possible errors made during the assembly are not covered by the warranty of MANUFACTURER our company advices the installation to be made after the following checks Minimum volume of the space where the pellet stove is installed avoid spaces smaller than 40m 3 Provide good air flow Observe all the norms Proper...

Страница 8: ... be any obstacles The air may be also taken from another room which is constantly ventilated and in which there is no other pellet stove or other system which needs an air intake That room can not be a bedroom toilet another space where there is a danger of fire such as a garage basement warehouse containing inflammable materials If there is a pellet stove in the same room using gas from an open s...

Страница 9: ... made of special pipes with adequate silicon sealer to be able to operate under high pressure and under temperature ranging from 200 250 o C pipes with thickness not less than 1 mm is recommended If the pellet stove is connected to the existing system the system should be checked by an authorized person The system cannot be installed indoors Periodical cleaning of the exhaust gas system is recomme...

Страница 10: ...less than twice than the one of the pellet stove the manufacture should protect the system against rain snow and wind easy dissassembling for cleaning purposes possibility for atractive finish which fits to the building The system should not have obstacles at a distance of less than 10 m such as walls trees In such a case the system should end 1 m above the obstacles and in case of other systems 2...

Страница 11: ...emperature shock Do not place inflammable objects near the pellet stove 4 2 FUELS The only fuel which is allowed for use by the Manufacturer pellet stove is the wooden pellets In order to guarantee combustion without problem the pellets should be kept in a dry place We recommend usage of high quality pellets compact and not powder like Inform yourself at your pellet vendor which pellets are the be...

Страница 12: ... phase at power1 From 0 1 to 8 0 1 2 07 Coclea power 2 ON time in working phase at power2 From 0 1 to 8 0 1 4 08 Coclea power 3 ON time in working phase at power3 From 0 1 to 8 0 1 7 09 Coclea power 4 ON time in working phase at power4 From 0 1 to 8 0 2 1 10 Coclea power 5 ON time in working phase at power5 From 0 1 to 8 0 2 5 11 Delay Alarms Delay in alarm signaling From 20 to 90 90 12 Cleaning f...

Страница 13: ...Temperature delta in adjustment phase From 0 C to 15 C 2 07 Del off auto Stand by delay adjustment From 0 to 120 2 08 Change output Waiting interval for power change From 0 to 60 20 09 Enable remote OFF ON ON 10 FROZEN KEYBOARD Enablement of keypad lock OFF ON OFF 11 Black out From 0 to 60 20 For exit simple just push button NO4 till go back to normal position of display 4 5 DISPLAY OF THE CONTROL...

Страница 14: ...re remains stable for a time period which is defined by the PR2 parameter ignition Operation of the pellet stove As soon as the gas temperature exceeds the limit of the PR13 parameter and remains enough time in the PR2 parameter the pellet stove is transferred in the normal operation phase On the upper part of the display the strength is showed by P5 and P6 while on the lower part the room tempera...

Страница 15: ...ater temperature exceeds the value of Tseth2 3 C for a time period longer than set the stove is going off REPETEAD TURNING ON AFTER TURNING OFF DUE TO HIGH WATER TEMPERATURE The stove is turning on as soon as the temperature of the smoke decreases below the value of set and the water temperature is brought below the value of Tseth2 3 C Changing the room temperature To change the room temperature i...

Страница 16: ...the message OFF the engine of the transmission system is turning off and the fan speed is increasing The pump operates until the water temperature falls below the value of the PR33 parameter After 10 minutes the fan goes off CLEANING THE BURNER During the normal operation of the stove periodically according to PR03 parameter the cleaning of the burner is turning on and it lasts according to the ti...

Страница 17: ...o the quantity one tree absorbs to product the same quantity of pellets Pellets are totally natural product which entirely observe the living environment they are produced from pure wood throwing out the peel without using colors No glue is used to put this product together In essence the compactness of the pellets is allowed by an ingredient which is found in the tree LIGNITE Beside being an ecol...

Страница 18: ...wdust in the packaging which would mean that the product is not compact which results from a lot of humidity in the pellets The pellets should be smooth compact and shiny Check the dimension of the pellets whether they match the dimensions declared on the packaging IMPORTANT The usage of poor quality pellets may damage the functioning of your pellet stove which means that you will lose your warran...

Страница 19: ...t stove However it is possible after few hours of operation the glass to become dirty on the inner side depending on the quality of the pellets and the exhaust gas system In that case use cotton cloth or magazine paper with a small quantity of detergent for glass cleaning This cleaning should be performed only when the pellet stove is cooled down After each cleaning check the glass if there is a d...

Страница 20: ...least once a month firstly you should empty it and then clean it using a vacuum cleaner GAS SYSTEM It is recommended to clean the general gas system once a year To do it it is necessary to open the door to take out the ash tray After that clean the system using a vacuum cleaner ...

Страница 21: ...ir system whether there is any obstacle in it EXHAUST GAS SYSTEM At the beginning of the heating season you should clean the exhaust gas system If the electrical cable is damaged replace it IMPORTANT For cleaning the colored surfaces do not use cleansers containing acid 7 0 Electric connection diagram Figure of the main board ...

Страница 22: ...I High smoke temperature ALARM HOT TEMP No ignition ALARM NO FIRE Smoke fan does not work ALARM FAN FAIL Going off during operation ALARM NO FIRE No electric power supply ALARM STOP FIRE Safety pressure switch ALARM DEP FAIL Safety thermostat ALARM SIC FAIL Pressure in water system ALARM PRES At each alarm the stove goes off and the alarm is reset by pressing the P4 button ALARM PROBE FOR SMOKE TE...

Страница 23: ...23 ALARM HIGH SMOKE TEMPERATURE ALARM NO IGNITION ALARM GOING OFF DURING OPERATION ALARM SAFETY PRESSURE SWITCH ALARM SAFETY THERMOSTAT ...

Страница 24: ... installation of the stove by an authorized person Constraints The 2 year warranty period does not include all the electrical and electronic parts as well as the fan for which the guarantee period is one year The warranty does not include parts that normally wear out such as the rope glass and all the removable parts of the burner Exclusions The variations in the color of the colored parts because...