background image

32

This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2016

INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000, ROBUST 3000

ROBUST 3000

Water inlet

connection

Sediment

pre-filter

Inlet solenoid valve

Inlet pressure

gauge

Low-pressure

switch 

Booster

pump

Membrane

module

Operating

pressure

gauge

Flow restrictor

Drain outlet

High-pressure

switch

Carbon

post-filter

Tank

connection

Permeate outlet

Figure 3

Technological  scheme  of  RObust  3000  is  shown  in  Figure  2.  After  the  pre-filters,  the  pressure 

booster  pump  feeds  the  water  to  the  reverse  osmosis  membrane  array.  Permeate  from  both 

modules goes to the permeate collector, and the concentrate from the 1

st 

module goes to the 2

nd

 

one. Second stage permeate goes to the permeate collector, and concentrate is discarded to drain 

via concentrate flow restrictor and drain port in port rack. Pressure gauge no. 2 shows pressure 

between two membranes. Permeate goes to the purified water line or pressure tank (if installed), 

passing through the carbon post-filter. Purified water line may go to the purified water faucet (not 

included) or be connected with some other consumer appliance. High-pressure switch installed 

before the post-filter reads pressure in permeate line and starts the reverse osmosis system when it 

drops (due to taking of some water from the pressure tank or opening purified water faucet). When 

the system switches on, entry solenoid valve is opened and booster pump is powered up, which 

allows to feed water into the system. When purified water stops being drawn from the system, 

pressure starts to build up and closes high-pressure switch switching off the system.
RObust  3000  system  has  low  feed  water  pressure  protection  implemented  with  a  low-pressure 

switch,  which  prevents  the  pump  and  solenoid  from  operating  if  feed  pressure  is  less  than  

0.4 bar (5.8 psi). Two pressure gauges on the front panel show operating pressure in the system, 

which allows diagnosing potential and occurring problems.

Содержание ROBUST 1000

Страница 1: ...ECOSOFT ROBUST 1000 ROBUST 3000 FOR REVERSE OSMOSIS SYSTEMS ECOSOFT ROBUST 1000 ROBUST 3000 INSTALLER AND USER GUIDE...

Страница 2: ...del 36 3 2 ECOSOFT RObust with pressure tank 37 3 3 ECOSOFT RObust with pressure tank and ultraviolet lamp 37 4 Installation steps 38 4 1 Installation conditions and package completeness check 38 4 2...

Страница 3: ...etrate through cellular membrane Ecosoft RObust is a high recovery direct flow operation capable reverse osmosis system The system can be equipped with a pressure tank for increasing purified water fl...

Страница 4: ...r line or pressure tank if installed passing through the carbon post filter Purified water line may go to purified water faucet or be connected with some other consumer appliance High pressure switch...

Страница 5: ...auge no 2 shows pressure between two membranes Permeate goes to the purified water line or pressure tank if installed passing through the carbon post filter Purified water line may go to the purified...

Страница 6: ...fied water Using the system with feed water above 30 86 F is advised against 2 SPECIFICATIONS AND COMPONENTS 2 1 TECHNICAL SPECIFICATIONS Parameter Value RObust 1000 RObust 3000 Purified water flow ra...

Страница 7: ...m 0 5 Total iron mg L ppm 0 3 Total manganese mg L ppm 0 1 COD mg O2 L ppm O2 5 Total microbial count TMC CFU per 1 mL 100 E coli CFU per 100 mL None 1 If feed water quality does not meet specified re...

Страница 8: ...is prohibited 2016 INSTALLER AND USER GUIDE FOR REVERSE OSMOSIS SYSTEM ECOSOFT ROBUST 1000 ROBUST 3000 4 Feed adapter 6 Purified water faucet 7 Feed valve 1 Filter rack with booster pump 5 Drain saddl...

Страница 9: ...o connection Inlet Run red tube from feed water outlet to the inlet port in port rack CAUTION The additional accessories should be used for the installation of RObust 3000 reverse osmosis system These...

Страница 10: ...included in the system components Purified water Run blue tube from purified water port to purified water faucet Drain Run black tube from drain port to drain saddle installed on drain pipe Pressure t...

Страница 11: ...alist company for assistance selecting the appropriate product for normalizing the offending constituents 3 Before proceeding with the installation ensure there is enough space for the assembled syste...

Страница 12: ...eed valve tube connection Slip red tube through the nut and connect it to the feed valve tube connection then screw compression nut back on till snug Connect the other end of the red tube to the inlet...

Страница 13: ...ath sink surface 7 3 Put compression nut on the free end of the blue tube then put on the ferrule and the insert inside the tube 7 4 Push the end of the blue tube inside the shank bottom a few centime...

Страница 14: ...s to rinse membranes and other parts of the system Do not open tank valve at this time Close the purified water faucet and check all connections for leaks CAUTION Inspect the system for leaks every da...

Страница 15: ...that pre filter is clogged and need to be replaced as soon as possible Delayed replacement of pre filters can result in damage or failure of the membranes In order to avoid this it is recommended to r...

Страница 16: ...aler s service If pressure on the 2nd pressure gauge is over 7 bar 101 5 psi this could be due to pressure regulator failure or the RO system s high pressure switch fault Contact your dealer s service...

Страница 17: ...water becomes free of carbon particles close feed water valve Plug the tubes back in the inlets in membrane housings Secure connections with locking clips 8 Open feed valve and plug the system in the...

Страница 18: ...ble cause Method of handling Fitting leak Tube is not connected tightly Remove and reinstall the tube properly Filter housing leak O ring seal is missing or mis aligned Check that the O ring seal is c...

Страница 19: ...ace membranes The system has switched off but continues to send water to drain Solenoid valve failure Replace the solenoid valve Protect the system from de bris and particulates if present in feed wat...

Страница 20: ...Contamination of pressure tank Sanitize pressure tank Pressure tank may become contaminated if filters or membranes are used beyond their service life Pressure tank is not full when the system switche...

Страница 21: ..._________________________________________________________Signature___________ Date__________ Installer____________________________________________________________________ Signature___________ Date____...

Страница 22: ...e No claims were made as attested to by signa tures below ROBUST RO SYSTEM MAINTENANCE REPORT FORM Step Result Remarks Date of service Specification of service Used consumables product name lot date o...

Страница 23: ...ored indoors protected from mechanical damage moisture and aggressive chemicals in vendor s original packaging at an ambient temperature in the range of 5 40 C 41 104 F and relative humidity up to 80...

Страница 24: ...this manual and use of consumables from other vendors Claims of water quality issues including taste odor and other properties will only be accepted with water test report issued by an accredited lab...

Страница 25: ......

Отзывы: