12
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2018
USER’S MANUAL. AQUAPOINT FILTER
3. INSTALLATION AND STARTUP
3.4. CHANGE OF WATER FLOW DIRECTION IN THE SYSTEM
The design of the system provides possibility to change the current water flow direction to the
opposite. In order to perform this, it is necessary to:
1. Disconnect demountable joints of pipelines.
2. Screw out 8 fixation screws of filters heads and switch their places preserving the direction of
the flow.
The procedure should be performed by a service center specialist.
3.5. SYSTEM ENHANCEMENT
The system can be enhanced to the MAKE BETTER level by connection of additional water treat
-
ment stages between the filters (see the connection scheme on page 7). For the connection please
take the following steps:
1. Disconnect demountable sockets in the back in the center.
2. Screw out the nipple (or leave it in one of the corners if you are planning to use it for connection).
Connect additional water treatment scheme between the filters. Any of the connection lines can be
directed up or down with the further turn to any side.
Button to evacuate the air
OVERHEAD VIEW OF THE SYSTEM
Button to evacuate the air
Demountable
socket
Nipple