Range 14
– ASDM22
Operating instructions
ECOSAFE | Date du document : 19/06/2019 – Version : 01
3
It has to be lifted only by suitable equipment (suct
ion cup, strap…). It has to be carried in a vertical position, and it must not be lying.
It is imperative not to tilt the cabinet when it is carried. Indeed it can cause damages that can alter the right functioning of the cabinet.
On the other hand, if it has to be moved, the cabinet has to be placed on a pallet and strapped, as to avoid any fall.
Commissioning
After having unwrapped the cabinet, ensure that you also received a set of two keys.
Your safety cabinet has to be installed, used and maintained as to guarantee the users protection.
4. INTERNAL EQUIPMENTS
The cabinet is provided with 8 retention shelves in steel, 2 protective shelves in PVC, 3 retention tanks in steel and 1 retention tank in
PVC. The retention capacity per shelf is 7 liters and per retention tank 25 liters.
Take care not to exceed the loading capacity per shelf of 50 KG.
The shelves must be fixed at the chosen height thanks to the rack and pinion.
5. STORAGE
Your safety cabinet is exclusively destined to store low risk chemicals in laboratories, industries, schools
… in closed containers.
It must not store high concentrated corrosive products or very flammable products.
We remind you that the storage of corrosives can alter the quality of your safety equipment. On the other hand, we remind you that
damages due to a bad use of the equipment and in particular to corrosion won
’t be covered by our warranty.
6. VENTILATION
We highly recommend connecting your safety cabinet to a ventilation system, as to evacuate the eventual vapors contained in it.
The air renewal has to be at least 10 times the volume of the cabinet, per hour. Moreover, ensure that the ventilation runs 24h/7.
Connection to a ventilation system
The air inlets are situated at the bottom, on the doors ; the outlet is situated on the top. See the schema below.