background image

CAUTION: read manual carefully for proper procedures and operation.

OWNER’S MANUAL

• Application

• Notable Features

• Specifications

• Installation

• Operation

• Maintenance

• Warranty

Ozone Blaster Adjustable

 

Electronic Air Purification

310

 

T.

 

Elmer

 

Cox

 

Drive

 

 

Greeneville,

 

TN

 

37743

 

 

(888)664-1812

www.EcoQuest.company

Содержание Ozone Blaster

Страница 1: ...ures and operation OWNER S MANUAL Application Notable Features Specifications Installation Operation Maintenance Warranty Ozone Blaster Adjustable Electronic Air Purification 310 T ElmerCoxDrive Greeneville TN 37743 888 664 1812 www EcoQuest company ...

Страница 2: ...erial number of your CAIR unit Serial ____________________________________________________________ Please record the name and phone of your EcoQuest Dealer _______________________________________________________________Name ______________________________________________________________ Phone CAUTION Disconnect power cord before servicing Use 1 0 AMP slow blow fuse CAUTION Do not operate unit witho...

Страница 3: ...ntrol No Residual Contamination Plugs into 110 or 220 volt outlet Specifications Ozone Generation Features Adjustable fan speed control Washable permanent lint screen Adjustable ozone control Electrical 120 volt 60 Hz or 220v 50 Hz 30 watts power consumption Mechanical 350 CFM fan One front mounted control for ozone output Size Height 11 3 4 Width 8 Depth 9 3 4 Weight 16 pounds Ozone Output 0 1 20...

Страница 4: ...dew bacteria and viral organisms It cleanses the air rather than filtering it masking the symptoms or attempting to dilute it PRE INSTALLATION AND INSPECTION 1 Remove unit from shipping carton 2 Remove all protective materials 3 Check for shipping damage and loose or broken parts 4 Read Owners Manual thoroughly prior to installation 5 Remove EcoTech Purification Plates from the box and install 6 O...

Страница 5: ...ge between the posts and clips making sure the metal clip on each side of the plate is in contact with the metal screen on the plate 3 Re install lint screen as shown below LINT SCREEN INSTALLATION 1 Always install bottom of lint screen first 2 The white lint screen tab should depress the safety switch arm down 3 Fit top of lint screen into cabinet Unit will not operate if safety switch is not dep...

Страница 6: ...tive when placed in a position that allows the ozone to be mixed evenly and thoroughly with the polluted air Suggested locations listed in the order of preference 1 Nearest the source of the worst pollution 2 Near a cold air return to thoroughly circulate clean air throughout the area 3 In the area most heavily used to achieve maximum benefit Note For maximum control the unit should be placed wher...

Страница 7: ... of time 3 OZONE INFORMATION Ozone is one of the most powerful oxidizing gases found in all outdoor environments It is capable of reacting or destroying vast numbers of organic materials found in indoor environments Used in low dosages it is capable of controlling odors and restricting the growth of or killing molds mildews bacteria and other microorganisms As with all useful materials and tools s...

Страница 8: ...te DO NOT ENTER OZONE TREATMENT IN PROGRESS MAINTENANCE Periodic maintenance is required to insure that the Ozone Blaster Adjustable operates properly A severely polluted environment can foul an EcoTech Purification Plate in as little as two weeks or as long as a year Shown here are basic maintenance procedures that should be carried out to keep your unit running at top performance Rear lint scree...

Страница 9: ...the electrical tabs are in contact with the plate Plate Card Cage Also be sure to clean the stand offs at the corners of the ozone plate card cage A cotton swab with alcohol works well Fan Blade and Front Grill Wipe off fan blade and front grill if dirty with damp washcloth The fan requires no maintenance with the exception of the first time it is used when it may be necessary to give it a gentle ...

Страница 10: ...l Order new plates from your Dealer Electrical stainless steel contacts are not contacting the screen portion of the EcoTech Purification Plate s Inspect the unit for any loose connections Do not attempt to disassemble the unit due to the Limited Warranty of the product 3 The EcoTech Purification Plate s are making a noise have a burning smell and or appear to arc or spark What is the problem Plat...

Страница 11: ...int screen installed properly to depress the safety switch forward 6 Air flow is restricted or reduced Is the unit properly placed away from objects that may obstruct air flow Are the filter and fan housing clean If your unit fails to operate properly after performing trouble shooting contact your EcoQuest Dealer for further assistance contact us at the address located in this manual or visit www ...

Страница 12: ... See warranty card for specific details If you have any questions concerning your Ozone Blaster system please see your local EcoQuest Dealer If your unit is defective please contact EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 or visit technical help Did you forget to register your Ozone Blaster By registering you ll activate your warranty and your privacy is guaranteed Just f...