background image

English

10

We also recommend to periodically grease the axles at the moving parts with a liquid grease spray. Lay
the couch on its side and take off the white caps protecting the nuts at the axles of the framework. Slightly
unscrew the nuts and spray the product around the loosen nuts. Leave to settle in this position for 12
hours. Tighten the nuts and put the protective white caps back on. Lay the table on the other side and
repeat.
Periodically check the couch visually for any signs of damage and make sure that all bolts, nuts and other
fasteners are tight.
* Please note that the repeated exposure of the table to high levels of humidity is not recommended.

b) Electric MOTOR

Keep this piece free from any dust or grease.
Absolutely avoid spilling liquids on the motor because they could cause severe damage to the electric
components despite the motor protection.
THE HANDLING OF THE ELECTRIC MOTOR IS TOTALLY FORBIDDEN. Any manipulation will
invalidate the guarantee. 
A non-stop blinking operation of the foot rail or any other height adjustment mechanism could activate the
thermal protection of the motor due to an overheating.
For further information, go to annex “FREQUENTLY ASKED QUESTIONS ABOUT MOTORS”.
Examine the table periodically for any signs of damage or malfunction and contact immediately the reseller
or Ecopostural for service/ spare parts.

c) Section adjustment MECHANISMS

Keep the mechanisms free from any dust or grease.
THE HANDLING OF THE GAS SPRING AND/OR THE ELECTRIC MOTOR IS TOTALLY FORBIDDEN.
Any manipulation will invalidate the guarantee.
If any malfunction or failure is suspected, contact immediately the reseller or Ecopostural.

d) UPHOLSTERY

A wet cloth should be enough to do the dusting. Anyway, if the leather is not properly clean you can use a
smooth sponge soaked with neutral soap water. Dry immediately afterwards. To prevent moisture from
entering the seams, do not wash with abundant water.
It is highly recommended to use a towel cover like the A4469, A4459 or A4460 to protect the upholstery
from sweat, massage creams or oils.
Use soapy water to clean the stains. Avoid using alcohol, any solvent or stain remover as the vinyl
could be seriously damaged.
The use of infrared lamps might cause a cracking of the artificial leather. You should then put a cotton
sheet or towel on the couch.
* For further details please CHECK THE ENCLOSED UPHOLSTERY INSTRUCTIONS.

All our equipment is covered by a 3 years guarantee, from the original invoice date, against any
manufacturing flaw or mechanical defect. It will be thus necessary to keep the invoice or any other
purchasing document as proof of guarantee.
Wear and tear of the artificial leather will not be covered by the guarantee.
The following conditions will invalidate your guarantee: any damage or deterioration caused by misuse
(e.g. inappropriate leather cleaning), by an undue unwrapping with a cutter (e.g. upholstery rips and tears)
or by accident.
In those cases where the guarantee applies, Ecopostural will repair or replace the faulty part free of charge
and return it at our expense within the EU territory.
For full details of the guarantee, please contact your supplier.

Содержание C5528

Страница 1: ...ILLA ELÉCTRICA ELECTRIC TABLE TABLE ÉLECTRIQUE INSTRUCCIONES INSTRUCTIONS Leer antes de utilizar por primera vez Read carefully before the first use A lire avant la première utilisation Actualización 05 04 2017 ...

Страница 2: ... defectuosas o usadas deben reponerse inmediatamente utilizándose única y exclusivamente las piezas originales de repuesto del fabricante para cada modelo en concreto Todo accesorio parte o pieza debe encajarse y colocarse de acuerdo con las instrucciones del fabricante Los componentes ajenos podrían resultar peligrosos para las personas que manejen la camilla Aviso En caso de utilizar piezas no o...

Страница 3: ...A El sistema de elevación es mediante un motor eléctrico El motor se sirve desconectado Antes de enchufarlo a la corriente proceda a su conexión siguiendo las instrucciones expresas que lo acompañan Para funcionar el cable de alimentación debe estar enchufado a una toma de 220 230V Al subir y bajar la camilla ASEGÚRESE DE QUE NI EL PACIENTE NI EL TERAPEUTA QUEDEN ATRAPADOS entre las partes móviles...

Страница 4: ...cionamiento contacten con su proveedor o con Ecopostural d TAPICERÍA Se recomienda quitar el polvo con un trapo húmedo Cuando no sea suficiente limpie con agua jabonosa y una esponja suave y seque completamente con un trapo Evite lavar y enjuagar con cantidades excesivas de agua para que no penetre por las costuras Para una mejor protección frente a sudor cremas o aceites de masaje se recomienda e...

Страница 5: ...rse de manera diferente con respecto a los residuos urbanos Una vez transcurrida su vida útil deberá depositarse en un centro de recogida específica La separación de desechos de productos usados y embalajes permite que los materiales puedan reciclarse y reutilizarse La reutilización de materiales reciclados ayuda a evitar la contaminación medioambiental y reduce la demanda de materias primas ...

Страница 6: ...Español 6 ...

Страница 7: ...porte de pacientes Portarrollos abatible blanco incorporado de serie Cabezal standard tipo T10 Cabezal redondeado Orificio lágrima y tapón incluido Módulo del cabezal respaldo regulable mediante pistón hidráulico Peso aproximado 80 Kg Características del Tapizado Tapizado en polipiel ignífugo Clase M 2 según normativa CE Con protección antimicrobiana y antibacteriana Sanitized Disponible en 22 col...

Страница 8: ...y replaced by original pieces by the manufacturer depending on the table model All components parts or accessories should be fitted or fixed in according to the special manufacturer s instructions Any spare replacement component part different to the manufacturer s could be dangerous for the people involved in the table handling Notice The use of non original pieces or the alteration of the item w...

Страница 9: ...ard as these parts are not aimed at supporting such a pressure c HEIGHT adjustment The central height of the table is operated by an electric motor The motor supplied in our electric tables is sent disconnected Before plugging the table in connect the air pipes according to the attached instructions To operate the supply cable must be plugged into a 220 230 V socket SAFELY POSITION PATIENT BEFORE ...

Страница 10: ...R THE ELECTRIC MOTOR IS TOTALLY FORBIDDEN Any manipulation will invalidate the guarantee If any malfunction or failure is suspected contact immediately the reseller or Ecopostural d UPHOLSTERY A wet cloth should be enough to do the dusting Anyway if the leather is not properly clean you can use a smooth sponge soaked with neutral soap water Dry immediately afterwards To prevent moisture from enter...

Страница 11: ...ct to a specific EC Directive and it must be followed accordingly as shown by the crossed skip symbol Therefore at the end of its useful life you will have to apply to a specialized waste disposal centre Separate Collection of used products and packaging allows materials to be recycled and used again Re use of recycled materials helps prevent environmental pollution and reduces the demand for raw ...

Страница 12: ...English 12 ...

Страница 13: ...r patient transportation Detachable white paper roll holder included as standard Standard headrest type T10 Rounded headrest Oval breather hole and bung included Head Backrest adjustable by gas spring Approx weight 80 Kg Upholstery Features Fire resistant Class M2 artificial leather EC compliant Sanitized anti microbial and antibacterial protection Available in 22 colours Foam thickness 4 cm Foam ...

Страница 14: ...ment l état du câble et de la prise en prenant toutes les précautions nécéssaires et en évitant de plier le câble Les pièces défectueuses ou usées doivent être remplacées immédiatement par des pièces de rechange provenant du fabricant d origine pour chaque modèle de table Tout accessoire pièce ou partie entière doit s emboiter et se placer selon les instructions du fabricant Les pièces détachées d...

Страница 15: ...se relever en poussant sur les bras pour se mettre de nouveau en position assise et pouvoir descendre de la table Attention Le patient ne doit jamais s appuyer sur la têtière ou le dossier pour s aider à se relever car ceux ci ne sont pas conçus pour supporter une telle pression c Réglage de la HAUTEUR Réglage de la hauteur par moteur électrique Le moteur est livré déconnecté Avant de le brancher ...

Страница 16: ...PAS LE VERIN HYDRAULIQUE ET OU ELECTRIQUE car cela entrainerait l annulation immédiate de la garantie En cas de mauvais fonctionnement ou panne veuillez contactez immédiatement votre distributeur ou Ecopostural d SELLERIE Enlevez la poussière avec un chiffon humide Si cela n est pas suffisant nettoyez avec de l eau savonneuse et une éponge douce puis séchez immédiatement avec un chiffon Evitez de ...

Страница 17: ...e aux les déchets urbains A la fin de sa vie utile cet appareil doit être déposé dans un centre de tri des déchets pour un recyclage adéquat qui respecte l environnement et la santé La collecte séparée des produits et emballages usés permet le recyclage des articles afin de les utiliser à nouveau Le fait d utiliser à nouveau des produits recyclés permet d éviter la pollution environnementale et de...

Страница 18: ...Français 18 ...

Страница 19: ...nts Porte rouleau blanc rabattable inclus de série Têtière standard type T10 Têtière arrondie Cavité visage en forme de goutte et bouchon inclus Têtière dossier réglable par vérin à gaz Poids approx 80 Kg Caractéristiques Sellerie Revêtement en simili cuir ignifuge de catégorie M2 conforme aux normes CE Protection antimicrobienne et antibactérienne Sanitized Disponible en 22 coloris Épaisseur de l...

Отзывы: