Ⅵ
.Operation introductions
Water heater
1) Controller introduction
ON/OFF
MODE UP/DOWN
SET
TIMER
1
2
Cooling mode
Set point temp
Heating mode
Tank outlet temp
Timer on
Timer off
Clock
Timer on/ off sign
First timer
Second timer
Press button to turn on or turn off the unit.
Press button to choose heating mode.
Long press this button for 3 seconds to enter parameter setting status inquiry.
S/N Content
0 Water inlet temp sensor
1 Ambient temp sensor
2 Coil temp sensor
3 Exhaust temp sensor
4 Gas suction temp sensor
5 Electrical expansion valve running status
6 Water outlet temp sensor
7 Reservation
8 Working mode
2) Wire Controller Operation
Range
0℃ ~ 85℃
-30℃~85℃
-30℃~85℃
50℃~120℃
-30℃~85℃
0℃ ~ 85℃
0℃ ~ 85℃
1 heating only
0 cooling & heating
7
Actual tested value