.Operation introductions
Water heater
Press or to directly adjust the temperature.
Press button and button at the same time, can turn on/off electrical heating.
Press button and buttons for 3 seconds, force defrosting function is on.
Press button once, to enter clock setting.
When long press this button for 10 seconds, can check and adjust the parameters
along with up or down buttons.
Parameters reference table
Parameters
Heating set point temp
Cooling set point temp
Temp difference setting
Water outlet temp adjustable
Defrosting period
Temp to enter defrosting
Max defrosting time
Temp to exit defrosting
To exit auxiliary heating (ambient temp)
Maximum set point temp
High pressure switch
Low pressure switch
Flow switch
Target over-heat degree
Second set point (maximum setting)
Second set point (minimum setting)
System
Single phase/ 3 phase
S/N
0
1
2
3
4
5
6
7
8
9
a
b
C
D
E
F
Default
12
5
0
45min
-2
8min
15
12
60
1(yes)
1(yes)
1(yes)
5
50
30
50
Reserved
0: single phase (220v)
1: three phase (380v)
C
C
C
C
C
C
C
C
C
C
Range
8 -25
2 -15
0 - 10
20min-90min
-30 - 0
3min-15min
5 - 25
0 - 40
35 - 65
0-1
0-1
0-1
-5 - 15
40 - 50
20 - 30
0-1
0-1
20 -60
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Under stand by/start-up state, press button, when the place which shows hour is
flashing, press or to adjust the hour; press button again, when the place
which shows minute is flashing, press or to adjust the minute, then press
button again, confirm the time setting.