.Operation introductions

Water heater

Press          or          to directly adjust the temperature.

Press     button and       button at the same time, can turn on/off electrical heating.

Press     button and       buttons for 3 seconds, force defrosting function is on.

Press         button once, to enter clock setting.

When long press this button for 10 seconds, can check and adjust the parameters 

along with up or down buttons.

Parameters reference table

                       Parameters

Heating set point temp

Cooling set point temp

Temp difference setting

 Water outlet temp adjustable  

 Defrosting period 

 Temp to enter defrosting

 Max defrosting time

Temp to exit defrosting

To exit auxiliary heating (ambient temp)

 Maximum set point temp

 High pressure switch

 Low pressure switch

 Flow switch

 Target over-heat degree

 Second set point (maximum setting)

 Second set point (minimum setting)

 System 

 

Single phase/ 3 phase

S/N

 

0

1

2

3

4

5

6

7

8

9

a

b

C

D

E

F

Default

12

5

0

45min

-2 

8min

15 

12

60 

1(yes)

1(yes)

1(yes)

50

30

50

Reserved

0: single phase (220v)
1: three phase (380v)

C

C

C

C

C

C

C

C

C

C

    Range

8     -25

2     -15

0    - 10 

20min-90min

-30     - 0 

3min-15min

5    - 25   

0    - 40   

35    - 65 

0-1

0-1

0-1

-5     - 15 

40    - 50

20    - 30

0-1

0-1

 

20     -60

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

Under stand by/start-up state, press       button, when the place which shows hour is 

flashing, press        or        to adjust the hour; press       button again, when the place 

which shows minute is flashing,  press       or       to adjust the minute, then press 

button again,  confirm the time setting.

8

Содержание SWBC-13.5H-B

Страница 1: ...Installation Instruction Manual AIR SOURCE HEAT PUMP WATER HEATER Model SWBC 13 5H B SWBC 19 5H B S SWBC 24 0H A S...

Страница 2: ...before installation Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 7 Wire Circuit Diagram 11 Installation instructions 13 Maintenance 17 1 CONTENTS Wate...

Страница 3: ...nents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water or h...

Страница 4: ...city to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Hot Water Heat pump water heaters are...

Страница 5: ...ation the low pressure compressor refrigerant gas inhalation in the compressor after working through the compressor a high temperature and high pressure of the refrigerant gas from the compressor to e...

Страница 6: ...4 0H A S 1 25 1 1 250 850 59 810 780 960 160 Model Rated heating capacity w Power supply V Ph Hz Input power kw Running current A Thermostat factory setting Thermostat maximum setting Water connection...

Страница 7: ...A C D E H G F A B C D E F G H Model Size Measure mm The dimension for air source heat pump water heater Dimension Water heater 5 780 780 1035 100 275 440 760 425 470 1115 685 310 59 SWBC 13 5H B 440...

Страница 8: ...dimension for High efficiency tube in shell heat exchanger Measure mm Measure mm Dimension Water heater Model Size 388 310 H H1 SWBC 13 5H B 6 Model Size SWBC 19 5H B S SWBC 24 0H A S 350 265 310 220...

Страница 9: ...utton to choose heating mode Long press this button for 3 seconds to enter parameter setting status inquiry S N Content 0 Water inlet temp sensor 1 Ambient temp sensor 2 Coil temp sensor 3 Exhaust tem...

Страница 10: ...auxiliary heating ambient temp Maximum set point temp High pressure switch Low pressure switch Flow switch Target over heat degree Second set point maximum setting Second set point minimum setting Sy...

Страница 11: ...ambient temp is 18 deg c Parameter C is 50 deg c Parameter D is 30 deg c Then set point temp 50 50 30 15 5 18 5 5 When S1 disconnected set point temp control by LCD controller Refer to the setting of...

Страница 12: ...ensor failure Water inlet temp sensor failure Water flow switch protection High pressure protection 3 times within 1 hour Low pressure protection 3times within 1 hour Exhaust temp too high protection...

Страница 13: ...ng distance demand for heating S1 7 6 5 4 3 2 1 S2 AIR SOURCE HEAT PUMP WIRING DIAGRAM OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 Wire Circuit Diagram AIR SOURCE HEAT PUMP WIRING DIAGRAM S CM TO POW...

Страница 14: ...g distance demand for heating AIR SOURCE HEAT PUMP WIRING DIAGRAM GND R S T N COMP GND C B A CN5 CN1 Cn2 CN3 Cn4 NOUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 1 3 5 2 4 6 A1 A2 T1 L1 A1 A2 2 2 Transfo...

Страница 15: ...n below picture pay attention to arrow direction Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or the top of the building based on the size o...

Страница 16: ...own on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat pipeline collocation should be rational ensure to minimi...

Страница 17: ...check if the wiring is connected as wiring diagram and reliability of earth wiring c Check Pipeline system 1Check the pipeline system make sure the water supply pipes water return pipes pressure gauge...

Страница 18: ...least 2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degree...

Страница 19: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Страница 20: ...Air Source Heat Pump Water Heater...