Turn on the main water supply.  Open a cold water tap nearby and let the water run for a few 

minutes until the system is free of foreign material and air that may have resulted from the 

installation.  Once the water is running clear and free of air, close the water tap.   

 

 

INSPECT ALL PLUMBING CONNECTIONS AND THE INTERFACE BETWEEN THE MEDIA 

TANK AND ITS VALVE HEAD FOR LEAKS AND REPAIR ANY LEAKS FOUND BEFORE 

PROCEEDING. 

 

Open the bypass valve for the ecoTAC™ filter to the service position.  

Leave the bypass for 

the ecoPLUS™ filter in the bypass position.  

Slowly open a nearby faucet, allowing a slow 

flow of water.  It may take several minutes for the flow of water to arrive as the media tank 

will be slowly filling with water.  During this time, air will escape from the faucet.  Run the 

water until the system is free of air then close the water tap.  

 

 

Media Pre-Soak 

Set the bypass valve for the ecoTAC™ filter to the bypass position.  

Open the 

bypass valve on the ecoPLUS™ system to the “service” position.  Slowly open a nearby 

faucet, allowing a slow flow of water.  It may take several minutes for the flow of water to 

arrive as the media tank will be slowly filling with water.  During this time, air will escape from 

the faucet.  It is normal for the water to be highly discolored at this stage as carbon fines are 

purged from the system.  Continue until all air is purged.  Then, turn off the faucet and allow 

the media to soak for a minimum of twenty-four (24) hours.  Set the bypass valve on the 

ecoPLUS™ filter to the “bypass” position so you can use water during the media pre-soak 

process.  Run the nearby faucet until the water runs clear.

 

 

It is now safe to turn the electricity back on to your water heater. 

 

Final Media Rinse 

After the media has soaked for at least twenty-four (24) hours

, set the bypass valve on the 

ecoPLUS™ system to the “service” position again and open a nearby faucet and allow a slow 

flow of water to run for 5 minutes.  Thereafter, gradually increase the flow rate until a 

moderate flow of water is achieved and run at this level for at least another 10 minutes.  It is 

normal for the water to be discolored at this stage as carbon fines are purged from the 

system.  Gradually increase the flow rate a little more and run the water until it is completely 

clear.  If you notice a significant decline in flow rate to the faucet at any point in the process, 

shut the water off and wait 10 minutes, then resume the process where you left off.   

Содержание Pi3900 EP-1000-TAC

Страница 1: ...TION GUIDE ecoPLUS EP 1000 TAC PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY AFFECT THE PERFORMANCE OF YOUR SYSTEM VOID YOUR WARRANTY AND RE...

Страница 2: ...anic chemicals lead and more ecoPLUS delivers refreshing great tasting drinking water and protects your skin and hair from the damaging effects of these contaminants Our ecoTAC hard water conditioners...

Страница 3: ...ect the Bypass Assembly to ecoTAC Valve Head 16 Step 9 Connect the Inlet Assembly to the Housing Cap 17 Step 10 Connect the Bypass to the Inlet Assembly 18 Step 11 Connect the ecoPLUS Tank to the Inle...

Страница 4: ...avy components without assistance if you are not physically capable of safely carrying out the procedure If the water treatment system is to be left unattended for an extended period of time vacation...

Страница 5: ...SYSTEM DAMAGE INCLUDING WATER LEAKS AND CORRESPONDING PROPERTY DAMAGE AND MAY VOID YOUR WARRANTY It is very important to note that the presence of elevated levels of chlorine iron manganese hydrogen...

Страница 6: ...hstand pressures exceeding 90 PSI if your water pressure is greater than 70 PSI we recommend that you have a certified plumber install a pressure reducing valve ahead of the ecoPLUS system The system...

Страница 7: ...INIMIZE ANY PROBLEMS WITH COPPER AVOID APPLYING EXCESS FLUX ON THE INNER SURFACES OF THE PIPE AND USE A LOW CORROSIVITY WATER SOLUBLE FLUX LISTED UNDER THE ASTM B813 STANDARD FOR HOMES WITH SIGNIFICAN...

Страница 8: ...8 Step 1 Pre Installation Inspection...

Страница 9: ...end interior installation only The system cannot be allowed to freeze or severe system damage could occur The system should not be exposed to rain and it should not be installed in direct sunlight as...

Страница 10: ...e slightly below or flush to the top of the tank If the tube is protruding above the top of the tank the distributor is not nested correctly in the recess at the bottom of the tank Add enough water to...

Страница 11: ...gh media to fill the tank to about 1 2 to 3 4 full This is normal The media tank should never be filled to the top of the tank as the remaining space known as the freeboard is necessary for the media...

Страница 12: ...as gravel or media in the tank threads Screw the Valve Head onto the tank make sure that the riser tube inserts into the center hole in the upper screen and the control valve as you screw down the val...

Страница 13: ...top of the mounting bracket should be mounted EXACTLY 62 62 75 inches off the floor Use a carpenter s level to ensure that the bracket is mounted level to the floor You will need to ensure that there...

Страница 14: ...ensuring that it is securely screwed into the wall studs When the cartridge filter housing is full of water it is heavy so it is important to ensure that the mounting will be strong enough to support...

Страница 15: ...sump containing the filter cartridge onto the cartridge filter housing cap Hand tighten only do not use the spanner wrench Do not over tighten Excessive force is not required to obtain a good seal Ste...

Страница 16: ...he treatment tank This is completely normal and is necessary to allow the required freeboard to permit the media bed to completely fluidize during operation When water begins to flow into the bottom o...

Страница 17: ...Cap Refer to John Guest Quick Connect Style Fittings above First ensure the John Guest fitting is unlocked Then push the elbow end of the inlet assembly on to the black stem adapter as far as it will...

Страница 18: ...hed to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shipping This can be correct by picking the tank up and tapping it on a hard sur...

Страница 19: ...19 go to next page...

Страница 20: ...S treatment tank The black base of the media tank is not permanently attached to the rest of the tank If your tank appears to be crooked the base has likely been knocked out of alignment during shippi...

Страница 21: ...ric water heater or an on demand tankless electric water heater we highly recommend that you turn off the power to the heater while installing any water treatment equipment Turn off power to your wate...

Страница 22: ...e flexible stainless steel connector threads onto the stainless steel fitting in the same way as you would attach a garden hose to an outdoor faucet Do not use Teflon tape of other thread sealants and...

Страница 23: ...23 Common Installation Configuration Step 16 Initial Start up and Leak Testing Ensure that both bypass valves are in the bypass position SYSTEM...

Страница 24: ...the media tank will be slowly filling with water During this time air will escape from the faucet It is normal for the water to be highly discolored at this stage as carbon fines are purged from the...

Страница 25: ...ces of scale that have dislodged from your pipes This effect will stop once the pipes have been de scaled After installation of EcoTAC low or phosphate free cleaning products for clothes and dishwashi...

Страница 26: ...ning product that dissolves old scale that has built up before installation of the ecoTAC conditioner system CLR or Lime Away are good cleaner choices for this purpose We then recommend that you coat...

Страница 27: ...air is completely purged out of your system Faucet Aerators are Plugging with Calcium Deposits See What to Expect in the First Few Weeks above MAINTENANCE THE SYSTEM MUST BE DEPRESSURIZED BEFORE REMO...

Страница 28: ...ing from the cap using the spanner wrench included with original purchase of your system 3 Locate and remove the large O ring at the top of the sump Try not to remove any of the lubricant from the O r...

Страница 29: ...are designed for a life of 5 years or 1 000 000 gallons whichever comes first The replacement media kit for your ecoPLUS filter is EP 1000 R The replacement media for your ecoTAC filter is ScaleStop 5...

Страница 30: ...Quick Connect Fittings The John Guest Group of Companies Middlesex England Made in England NSF ANSI Standard 14 NSF ANSI Standard 61 G Flexible Stainless Steel Connectors Falcon Stainless Inc Temecula...

Страница 31: ...1000 Series Media 1 000 000 gallons or 5 Years whichever comes first Pro rated ecoTAC EP 1000 Series Media 1 000 000 gallons or 5 Years whichever comes first Pro rated All other components 1 year Note...

Страница 32: ...ized repair or damage caused through installation adaptation or modification use in an improper manner or manner inconsistent with the manufacturer s installation operating and maintenance instruction...

Страница 33: ...y of such damages or losses These warranties are governed by the laws of the Province of British Columbia Canada and may change without notice To report a warranty problem with your system or request...

Отзывы: