background image

WHF

Smart

C o n t r o l

Jan 2020

ON/OFF

MODE

SPEED

H

ON

Set

Cool

To

SPEED

Indoors

WHF

Smart

CAUTIONS

Use cautions when mounting components to surfaces that 
may have concealed wiring beneath the surface.

Turn off power before installing whole house fan or controls.

Read and follow all instructions carefully, including those 
included with the whole house fan. Read entire manual 
before installing products.

Follow all local electrical codes during installation. All wiring 
must conform to local and national electrical codes.

Installation should be performed by a qualified individual 
with sufficient experience and skill.

!

The WTTK kit includes a WTT Whole House Fan Wall 
Control, an FC3J Fan Control and a 50’ plug&play cable.

The optional TS3J Outdoor Temperature Sensor can be 
added to the installation to delay fan operation if the 
outdoor temperature is too warm to provide cooling. 

When servicing WHF controls, turn off all power to these 
items.

Step 3. Install a Plastic Retrofit Gang Box

INSTALLER MANUAL

Model WTTK

Whole House Fan Wall Control

Laguna Hills, CA

eControls

eControls

Model FC3J

eControlsUSA.com

For 1, 2 or 3-Speed PSC or ECM Fans

WARNING

 120VAC. 

Disconnect all power 

before wiring or 

servicing.

Violet-High Speed
Yellow-Med Speed
Red-Low Speed
Black-120VAC
White-Neutral

Wiring Key

Wire the FC3J to the fan using the diagram below as a guide. If 
the FC3J fan control is already installed on the fan, go to Step 2.

Step 1. Install FC3J in Junction Box on Fan

Connect to FAN High 

Speed Wire 

Connect to FAN Low 

Speed Wire
Connect to FAN Medium 

Speed Wire

Connect to POWER 

120VAC Wire 

Connect to FAN Neutral 
Wire and to POWER 
120VAC Neutral Wire

LS

MS

HS

120

VAC

NTL

Low Speed

Medium Speed

High Speed

120VAC Power

Neutral

Unused wires should be cut at the 
PCB or capped with wire nuts.

!

Laguna Hills, CA

eControls

eControls

Model FC3J

eControlsUSA.com

For 1, 2 or 3-Speed PSC or ECM Fans

WARNING

 

120V

AC. 

Disconnect all 

power before wiring 

Violet-High Speed
Yellow-Med Speed

Red-Low Speed
Black-120V

AC

White-Neutral

Wiring Key

Use the screws included to secure the 
FC3J to the junction box on the fan 
making sure there are no exposed 
wires and the fan control is securely 
inside the electrical box. Failure to do 
so could result in electrical shock.

The WTT is installed in a plastic retrofit 
single gang box in the sleeping space on a 
wall about 5’ off the floor in a location that 
will best sense the temperature for the 
space. Do not install in a location where 
the temperature will be influenced such as 
in direct sunlight, on an exterior wall, etc.

 

Do not install WTT in a metal gang box. 

Step 2. Connect Cable to the FC3J

Connect one end of the “RED” Plug&Play cable into the FC3J 
fan control already installed on the junction box on the fan. 

Feed this end 

to the gang box 

Insert into FC3J 

already installed 

on fan.

See FC3J Wiring Diagrams on pages 3-4 for wiring to 
fans manufactured by QC Manufacturing.

i