R
COM
CLS
OPN
COM
CLS
OPN
C
W
EQUIPMENT
Upstairs
Downstairs
Y
G
Upstairs
Sensor
Model A80-MOC
Damper Actuator
Modulating or
Open/Close
24VAC,2.4VA
COM
OPN
CLS
Made in USA
eControls, Inc.
Model A80-MOC
Damper Actuator
Modulating or
Open/Close
24VAC,2.4VA
COM
OPN
CLS
Made in USA
eControls, Inc.
G
HVAC System
Model R80CT-XX
Upstairs Damper
Model C365T11
Downstairs Thermostat
Model TS5
Upstairs
Temperature
Sensor
Model R80CT-XX
Downstairs Damper
Y
W
C
R
WIRING DIAGRAM
WIRING INSTRUCTIONS
Equipment Wiring
Warning!
Damper Wiring
Upstairs Temperature Sensor Wiring
Use 5-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the equipment.
Turn the power to the HVAC equipment off before wiring.
Use 3-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the upstairs and downstairs dampers.
There are separate terminals for the upstairs and the
downstairs dampers.
Multiple dampers can be used to construct the upstairs or
downstairs zones. Daisy chain terminals– COM to COM, OPN
to OPN and CLS to CLS.
Use 2-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the upstairs temperature sensor.
C365
Terminal
C365
Terminal
C365
Terminal
R
COM
SNR
C
CLS
SNR
W
OPN
Y
G
Wire Color
Wire Color
Wire Color
Red
White
White
Blue
Red
Red
White
Green
Yellow
Green
Equipment
Terminal
Damper
Terminal
Sensor
Terminal
R, Rc, Rh
COM
SNR
C
CLS
SNR
W, W1
OPN
Y, Y1
G
Function
Function
Function
24VAC Power
Common
Thermistor
Common
Closes damper
Thermistor
Heating
Opens damper
Fan
Cooling
For single temperature sensor application, use Model TS5-10.
Two temperature sensors can be installed in different areas
upstairs and the two temperatures will be averaged. For dual
sensor applications, use Model TS5-20 and daisy chain the
sensors.
3
C365T11
Upstairs
Sensor