eControls Comfort 365 C365T11 Скачать руководство пользователя страница 3

R

COM

CLS

OPN

COM

CLS

OPN

C

W

EQUIPMENT

Upstairs

Downstairs

Y

G

Upstairs

Sensor

Model A80-MOC

Damper Actuator

Modulating or
Open/Close
24VAC,2.4VA

COM

OPN

CLS

Made in USA

eControls, Inc.

Model A80-MOC

Damper Actuator

Modulating or
Open/Close
24VAC,2.4VA

COM

OPN

CLS

Made in USA

eControls, Inc.

G

HVAC System

Model R80CT-XX
Upstairs Damper

Model C365T11
Downstairs Thermostat

Model TS5
Upstairs
Temperature
Sensor

Model R80CT-XX
Downstairs Damper

Y

W

C

R

WIRING DIAGRAM

WIRING INSTRUCTIONS

Equipment Wiring

Warning!

Damper Wiring

Upstairs Temperature Sensor Wiring  

Use 5-conductor, 18 or 20 gage, thermostat cable to wire from 
the C365 Thermostat to the equipment.

Turn the power to the HVAC equipment off before wiring.

Use 3-conductor, 18 or 20 gage, thermostat cable to wire from 
the C365 Thermostat to the upstairs and downstairs dampers. 
There are separate terminals for the upstairs and the 
downstairs dampers.

Multiple dampers can be used to construct the upstairs or 
downstairs zones.  Daisy chain terminals– COM to COM, OPN 
to OPN and CLS to CLS.

Use 2-conductor, 18 or 20 gage, thermostat cable to wire from 
the C365 Thermostat to the upstairs temperature sensor.

C365

Terminal

C365

Terminal

C365

Terminal

R

COM

SNR

C

CLS

SNR

W

OPN

Y

G

Wire Color

Wire Color

Wire Color

Red

White

White

Blue

Red

Red

White

Green

Yellow

Green

Equipment

Terminal

Damper

Terminal

Sensor

Terminal

R, Rc, Rh

COM

SNR

C

CLS

SNR

W, W1

OPN

Y, Y1

G

Function

Function

Function

24VAC Power

Common

Thermistor

Common

Closes damper

Thermistor

Heating

Opens damper

Fan

Cooling

For single temperature sensor application, use Model TS5-10. 

Two temperature sensors can be installed in different areas 
upstairs and the two temperatures will be averaged. For dual 
sensor applications, use Model TS5-20 and daisy chain the 
sensors.  

3

C365T11

Upstairs
Sensor

Содержание Comfort 365 C365T11

Страница 1: ...ing only Cooling only Automatic Heating or Cooling Maximum upstairs and downstairs heating and cooling airflow limits are set during installation Option used when bedrooms are located upstairs C365 uses the upstairs temperature sensor to control heating and cooling calls and directs more airflow upstairs One Model TS5 10 or two Model TS5 20 upstairs temperature sensors can be used Round or rectang...

Страница 2: ...the battery cover downward and install the two AA batteries as shown R C W EQUIPMENT Y G Upstairs Sensor COM COM CLS CLS OPN OPN Upstairs Downstairs Install an R80CT damper in the duct supplying air to the upstairs and wire the terminals to the corresponding terminals on the C365T Install a second R80CT damper in the duct supplying air to the downstairs and wire it to the C365T Each damper uses 2 ...

Страница 3: ... upstairs and downstairs dampers There are separate terminals for the upstairs and the downstairs dampers Multiple dampers can be used to construct the upstairs or downstairs zones Daisy chain terminals COM to COM OPN to OPN and CLS to CLS Use 2 conductor 18 or 20 gage thermostat cable to wire from the C365 Thermostat to the upstairs temperature sensor C365 Terminal C365 Terminal C365 Terminal R C...

Страница 4: ... and Day NEXT ENTER AM Touch the UP DOWN keys to change the HOUR Touch NEXT to save the hour and go to change the minute CHANGE THE HOUR Touch the UP DOWN keys to change the MINUTE Touch NEXT to save the minute and go to change the day of the week CHANGE THE MINUTE Touch the UP DOWN keys to change the DAY OF THE WEEK Touch ENTER to save the day fo the week and return to thermostat operation CHANGE...

Страница 5: ... L 5 0 Airflow Update Time A F t 1 to 20 minutes 2 ACCESSING INSTALLER OPTIONS To access the Installer Options and the hidden Enter key for 7 seconds until the first Option appears on the screen TOUCH HOLD Inside Tu Day Upstairs Auto Downstairs Airflow COOL Schedule AUTO FAN MENU MODE Cool Set To SYSTEM AM TOUCH HOLD and this key for 7 seconds to access the Installer Options Touch the keys to set ...

Страница 6: ...e previous option UP DOWN NEXT ENTER BACK Option NEXT ENTER Touch the keys to select the cooling temperature when the space is vacant Touch to display the next option or to save the option and return to normal thermostat operation or touch the hidden key to return to the previous option UP DOWN NEXT ENTER BACK Option NEXT ENTER Cool Vacant Vacant Touch the keys to change the downstairs Inside temp...

Страница 7: ...ion NEXT ENTER Cool Touch the keys to select the maximum allowable downstairs airflow in heating Touch to display the next option or to save the option and return to normal thermostat operation or touch the hidden key to return to the previous option UP DOWN NEXT ENTER BACK Downstairs Airflow Option NEXT ENTER Heat Touch the keys to select the maximum allowable downstairs airflow in cooling Touch ...

Страница 8: ...stairs Airflow in Heating Upstairs Downstairs Airflow NEXT ENTER Heat To determine the maximum allowable downstairs airflow touch the key until the airflow is too great and causes noise or annoyance Increase the airflow using the key until it is acceptable This is the maximum allowable downstairs airflow in heating Record the airflow value DOWN UP Maximum Allowable Downstairs Airflow in Heating 05...