Inside
Tu
Day
Upstairs
Auto
Downstairs
Airflow %
HEAT
Schedule
AUTO
FAN
MENU
MODE
Heat
Set To
SYSTEM
AM
365
Comfort
UP/DOWN
Keys.
SYSTEM MODE
Key
OFF, HEAT, COOL or Auto
Displays the downstairs
(Inside) or upstairs (Inside2)
temperature.
Displays the Thermostat Mode
HOLD, SCHEDULE or VACANT
Displays the time, day and schedule
MORNING, DAYTIME, EVENING
or NIGHT
MENU
Key Displays
the User options.
MODE
Key Selects
Thermostat Mode
HOLD, SCHEDULE or VACANT
Displays the upstairs airflow
Displays the Airflow Mode
AUTOMATIC or MANUAL
Displays the heating or
cooling temperature
FAN MODE
Key
AUTO or ON
Description
System Modes
Airflow Limits
Nighttime Operation
Upstairs Temperature Sensor
Modulating Dampers
Power
Warranty
Compatible HVAC Equipment
Thermostat Modes
Programs per Day
Program Format
Temperature Override
Airflow Override
Airflow Modes
Fan Modes
The C365 thermostat controls the heating and cooling system
the same as most programmable thermostats. It also controls
the airflow to the upstairs and downstairs using an upstairs and
a downstairs modulating damper. A temperature sensor
located upstairs monitors the upstairs temperature and the
temperature sensor in the C365 monitors the downstairs
temperature.
The C365 adjusts the upstairs and downstairs airflow during
heating and cooling calls to maintain uniform upstairs and
downstairs temperatures.
Off, Heating only, Cooling only, Automatic Heating or Cooling.
Maximum upstairs and downstairs, heating and cooling airflow
limits are set during installation.
Option used when bedrooms are located upstairs. C365 uses
the upstairs temperature sensor to control heating and cooling
calls and directs more airflow upstairs.
One Model TS5-10 or two Model TS5-20 upstairs temperature
sensors can be used.
Round or rectangular dampers using the A80MOC actuator
and up to 1 inch static pressure.
Operates on 24VAC from the HVAC equipment using the R
and C wires.
Single stage gas or electric heating with single stage
compressor.
Hold, Schedule or Vacant mode.
Morning, Daytime, Evening and Night.
Weekdays and weekend– 5/2.
Up/down keys adjust the setpoint temperature. Temperature
setting is held for 4 hours when adjusted in Schedule mode.
Up/down keys adjust the upstairs/downstairs airflow. Airflow
setting is held for 4 hours when adjusted in Automatic mode.
Automatic or Manual when Manual mode is enabled.
Continuous or Automatic fan operation.
This thermostat is warranted to be free of defects due to
workmanship or materials under normal use and service for a
period of 5 years from date of installation and not longer than
6 years from manufacturing date code.
Installer Manual
Model C365T11
365
Comfort
eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653
949-916-0945 Fax 949-458-8502 www.eControlsUSA.com
eControls
eControls
Rev A Jan 2016
Displays the downstairs airflow
NEXT
Key
Used to advance through
options
ENTER
Key
Used to save options and
return to thermostat operation