Econo Heat OMNI EH-350 Скачать руководство пользователя страница 19

Page 19

EconoHeater by EconoHeat

This warranty is void if:

•  Warranty registration card is not returned within sixty (60) days of purchase

•  Any part or component subject to abuse or altered from original manufactures speciications
•  Installation not in accordance with instructions
•  Has not been properly maintained, operated or has been misused
•  Wiring not in accordance with diagram furnished with unit heater
•  Unit heater is operated in the presence of chlorinated vapors
•  Air through unit heater is not in accordance with rating plate and speciications
•  Target plate or clean out door warped/discolored from excessive heat

Warranty is limited to the original purchaser and is non-transferable. 

The above warranty is in lieu of all other warranties expressed or implied. EconoHeat does not 
authorize any person or representative to make or assume any other obligation or liability that 
is not in accordance with above warranty. 

EconoHeat is not responsible for any labor and/

or shipping cost, unless prior authorization in writing has been obtained.

NOTE:

 Combustion Chamber Warranty is speciic to material and workmanship. Workmanship 

means EconoHeat warranties the welds are good and will hold. Material means they will not 
corrode through due to sulfur in the ash that accumulates during operation. Warranty does 
not apply to units that experience overheating stress cracks. These are not incurred because 
the materials are inadequate for the application nor are they results of a weld breaking lose 
because of bad penetration, which is easily recognized by the metal left beneath the weld. 
These cracks occur as a direct result of (1)improper draft, either by inadequate initial installation 
and setup, which requires (a) establishing a proper draft during installation (b) back draft has 
occurred due to ash buildup, backing up hot gas passageways in either the exchangers, the 
stack, or both. (2) Over iring by setting oil supply pressure too high (see manual for proper 
setting) these are all cases of thermal overload.

*Under normal use only. If misuse or abuse is deemed apparent after inspection, warranty is void.

EH-350 Ten (10) Year Limited Warranty Cont.

Содержание OMNI EH-350

Страница 1: ...structions EH 350 120v Manual EconoHeat 5714 E First Avenue Spokane Valley WA 99212 800 255 1363 www econoheat com Rev 01 2017 Manufactured by Econo Heater 240 Omni Heat NZ P O Box 112 Cromwell 9342 3...

Страница 2: ...Installation Procedures Page 6 Stack Installation Page 7 Oil Supply Tubing Page 7 Wiring Page 8 Oil Burner Page 9 Oil Burner Technology Page 10 Initial Start Procedure Page 12 Maintenance Schedule Pa...

Страница 3: ...on and service of EconoHeat Waste oil ired heaters The following instructions should be carefully followed for obtaining the best possible installation operation and service conditions Speciications a...

Страница 4: ...l Maintenance Requirements Identical to any gas or oil furnace without adequate draft over the ire the combustion gases cannot escape the furnaces The lame will lengthen resulting in an overheated com...

Страница 5: ...hout notice in materials speciications and models or to discontinue models 2 These appliances are designed for commercial or industrial use only Installation and use of this waste oil burning applianc...

Страница 6: ...Page 6 EconoHeater by EconoHeat Installation Procedures Figure 1 Installation Diagram 1 2 3 4 ID copper tubing 8 stack...

Страница 7: ...achieved Oil Supply Tubing 1 Use ONLY 1 2 or 3 4 nominal ID copper tubing with lare ittings only on the fuel suction from the tank to the heater Do NOT use ferrule ittings or Telon tape on any pipe i...

Страница 8: ...circuit 20 amp protection using 12 gauge wire Connect power line to black wire and all whites NEUTRAL or COMMON together IMPORTANT Connect ground wire to ground mounting point in main junction box gr...

Страница 9: ...nal Electric Code ANSI NFPA 70 1990 and the requirements of the inspection authorities having jurisdiction WARNING Igniter Transformer Air Band Solenoid Valve Vacuum Gauge oil Figure 3 Oil Burner Back...

Страница 10: ...tion to the combustion chamber The waste oil enters into the Oil Pre Heater Block and is pre heated to operating thermo set point and this along with high pressure 100 psi to 500 psi depending on mode...

Страница 11: ...when door is closed Pre Heater Control Circuit Board igure 9 Precisely controls temperature of the Oil Pre Heater Block and controls safety feature of not allowing burner to energize until oil has est...

Страница 12: ...mostat terminals on the Oil Primary Control igure 3 Once the burner is running temporarily jump the F terminals on the Oil Primary not before burner tries to run or operate This will allow the burner...

Страница 13: ...or opposite of the burner assembly requires the removal of the access panel allowing simple entry to the combustion chamber and heat exchanger s to vacuum out the accumulated ash soot hepa ilter recom...

Страница 14: ...TION TO ENDCONE BURNER TUBE Tip of nozzle must be ahead of inside radius of end cone If nozzle is behind inside radius of end cone coking will occur and end cone can become clogged igure 8 below IMPOR...

Страница 15: ...lectrodes Nozzle Thermocouple Figure 9 Pre Heater Block Detail Removed From Burner for Clarity Figure 8 Electrode Adjustment Detail When cleaning inspect all three pieces thoroughly When disassembling...

Страница 16: ...eater by EconoHeat Figure 11 Oil Filter Pancake Style Filter Remove 4 bolts for access to strainer ilter CAUTION must be careful not to destroy the inner gasket during removal of the housing Figure 10...

Страница 17: ...Page 17 EconoHeater by EconoHeat Troubleshooting...

Страница 18: ...is to be sent to the factory with freight prepaid EconoHeat reserves the right to determine appropriate action for repair or replacement No parts will be accepted by EconoHeat without RA return autho...

Страница 19: ...pping cost unless prior authorization in writing has been obtained NOTE Combustion Chamber Warranty is speciic to material and workmanship Workmanship means EconoHeat warranties the welds are good and...

Страница 20: ...ill out tear off and return to manufacturer within sixty 60 days of purchase or warranty will not be valid Please print or type Date of Purchase Serial Model Customer Company Name Address City State Z...

Отзывы: