22
When it’s in manual frequency mode, in the home page, press this key to decrease the target
frequency.
5) “
” “POWERFUL” Key
When the heat pump is on, press this key shortly to enter into powerful mode.
6) “
” “SMART” Key
When the heat pump is on, press this key shortly to enter into smart mode
7)
“
” “SILENT” Key
When the heat pump is on, press this key to enter into silent mode
Long press key “
” for 5 seconds, and enter into the unit parameter inquiry interface,
press key “
,
” to check the parameters, press key “
”to exit parameter query.
Code
Description
Display Range
01
Water inlet temp.
-30~99
℃
02
Water outlet temp.
-30~99
℃
03
Ambient temp.
-30~99
℃
04
Exhaust temp.
0~125
℃
05
Suction temp.
-30~99
℃
06
Outer coil temp.
-30~99
℃
07
Inner coil temp.
-30~99
℃
08
Main EEV opening
0-480
09
EVI EEV opening
0-480
10(A)
Compressor current
11(B)
Radiator temp.
12(C)
DC bus voltage
13(D)
Compressor actual rotate speed
14(E)
DC fan motor 1 actual rotate speed
15(F)
DC fan motor 2 actual rotate speed