Do  not  operate  the  implement  in  the 
vicinity of in-flammable liquids or gases 
as this could give rise to the danger of a 
fire or explosion.

Work intervals:

After the implement has been turned off, 
the cutting cylinder will continue to rotate 
for a few seconds. Keep hands and feet 
well away.

Only  shift  working  depth  when  the 
implement is completely still standing.

Only remove plant parts and soil when 
the  imple-ment  is  standing  completely 
still.

Switch   off   the   power   when   the 
implement is to be transported,

 lifted or 

tilted and when traversing other surfaces 
than soil.

Never  leave  the  implement  unattended 
at the place of work.

Always  switch  off  the  implement  and 
disconnect the power plug:

Whenever you leave the implement

Before you clean the ejector opening 
or unblock or unclog the implement

When the implement is not being used

During  all  maintenance  and  cleaning 
work

When the power cable is damaged or 
has become tangled 

When   the   implement   hits   an 
obstruction  during  work  or  when 
unusual  vibrations  arise.  Establish  the 
cause  and  see  if  the  implement  has 
been damaged.

Do  not  repair  it  yourself!  Have  the 
implement  re-paired  by  an  authorised 
workshop!

Store the implement in a dry place well 
out of reach of children.

CAUTION! 

The following states how to avoid 

damage to the implement and any resulting 
harm to people:

Take care of your implement

Switch off the power when the implement 
is to be carried across steps.

lnspect the implement each time before it 
is  to  be  used.  Never  operate  the 
implement  if  safety  de-vices  (e.g.  impact 
protector,

  parts  of  the  cutting  facility  or 

bolts are missing, worn out or damaged. 
Check  especially  the  power  cable  and 
starting  lever  for  damage.  To  avoid 
imbalance,  all  tools  and  bolts  must  be 
exchanged as complete sets.

Only use spare parts and accessories that 
have been supplied or recommended by 
the manufactur-er. The use of alien parts 
results  in  the  immediate  loss  of  all 
guarantee claims. Ensure that all nuts, bolts 
and screws are firmly tightened and that 
the implement is in a safe working state.

Never try to repair the implement yourself, 
other  than  you  have  been  trained 
accordingly.  All  work  that  has  not  been 
listed  in  these  Instructions  must  only  be 
carried out by authorised servicing agen-
cies.

Treat the implement with the greatest care. 
Always keep the tool clean for better and 
safer  work.  Follow  the  maintenance 
instructions.

Never  overload  the  implement.  Always 
work within the specified capacity range. 
Do  not  use  low-power  machines  for 
heavy-duty  work.  Do  not  operate  the 
implement for purposes for which it is not 
intended.

Electrical safety:

CAUTION! 

The  following  states  how  to 

avoid acci-dents and injuries due to electric 
shock:

Before  each  use,  carry  out  a  visual 
inspection  of  the  power  and  extension 
cables for signs of dam-age or ageing.

lf  the  power  cable  for  this  equipment  is 
damaged,  it  must  be  replaced  by  the 
manufacturer, a customer service agent of 
the same or a similarly qualified person in 
order to prevent hazards.

Keep the power cable well away from the 
cutting  tools.  Should  the  power  cable 
become  damaged  during  work,  then 
instantly disconnect the power cable from 
the mains.

Keep the power cable well away from the 
cutting  tools.  Should  the  power  cable 
become  damaged  during  work,  then 
instantly disconnect the power cable from 
the mains.

DO NOT touch the power cable before it 
has been disconnected from the mains.

Keep the extension cables away from the 
teeth.  The  teeth  may  damage  the  cables 
and result in contact with live parts.

Check that the mains voltage is the same 
as indi-cated on the rating plate.

Wherever possible connect the implement 
to a power socket with a residual- current 
circuit break-er that has a rated current of 
not more than 30 mA.

Avoid body contact with earthed parts (e.g. 
metal fences, metal posts).

Only use approved extension cables of the 
type  HO5VV-F  or  H05RN-F  with  a 
maximum length of 75 m and which have 
been  approved  for  open-airuse.The 
stranded  cord  diameter  of  the  extension 
cable  must  be  at  least  2.5  mm2.  Always 
unreel a cable drum to its full length so that 
the  entire  cable  can  be  checked  for 
damage.

Use the envisaged cable suspension when 
attach-ing an extension cable.

Never  pull  the  cable  to  disconnect  the 
plug  from  the  socket.  Protect  the  cable 
from heat,

 oil and sharp edges.

lf the connecting cable is damaged, first 
disconnect the extension cable from the 
socket.  You  can  then  disconnect  the 
connecting cable of the equipment.

lf the power cable for this equipment is 
damaged,  it  must  be  replaced  by  the 
manufacturer, a customer service agent of 
the same or a similarly qualified person in 
order to prevent hazards.

lf the power cable for this equipment is 
damaged,  it  must  be  replaced  by  the 
manufacturer, a customer service agent of 
the same or a similarly qualified person in 
order to prevent hazards.

Residual risks
Even if you use this electric power tool in 
ac-cordance  with  instructions,  certain 
residual  risks

 

cannot  be  ruled  out.  The 

following hazards may

 

arise in connection 

with  the  equipment's  con-struction  and 
layout:

1.Damage  to  hearing  if  no  suitable  ear 

protection is used.

2.Health  damage  caused  by  hand-arm 

vibrations if the equipment is used over a 
prolonged period or is not properly guided 
and maintained.

3.Even when all safety measures are taken, 

some remaining hazards which are not yet 
evident may still be present.

4.Remaining  hazards  can  be  minimized  by 

follow-ing  the  instructions  in  Safety 
Precautions, Proper Use and in the entire 
operating manual.

5.lnjuries caused by the rotating blade.

6.Health  risks  caused  by  electricity.  When 

incor-rect  or  damaged  mains  cables  are 
used.  Follows  instructions  in  the  manual 
Electrical Connections.

Содержание ELG02

Страница 1: ...S MANUAL ELECTRIC CORDED TILLER WARNING Read carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious pers...

Страница 2: ...he proper order We recommend that where possible all items are assembled near to the area in which they will be placed in use to avoid moving the product unnecessarily once assembled Always place the...

Страница 3: ...MBOLS ONTHE EQUIPMENT 07 INTRODUCTION 08 DEVICE DESCRIPTION 08 SCOPE OF DELIVERY 09 INTENDED USE 09 SAFETYINFORMATION 09 OPERATION 14 ELECTRICAL CONNECTION 14 TROUBLE SHOOTING GUIDE 17 CLEANINGAND MAI...

Страница 4: ...01 https www altonindustries com 02 info altonindustries com Fig 1 3 1 1 9 4 7 6 5 1 3 3 9 1 9 10 3 4 10 FEATURES 5 4 6 12 13 2 1 7 8 9 10 1 1 Fig 2 Fig 3 Fig 4...

Страница 5: ...03 https www altonindustries com 04 info altonindustries com 3 1 15 16 14 17 8 7 7 17 7 12 13 2 1 1 3 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10...

Страница 6: ...20 19 18 6 05 https www altonindustries com 06 info altonindustries com Fig 12 Fig 11...

Страница 7: ...nd commissioning the device The operating instructions are intended to help the user to become familiar with the machine and take advantage of its application possibilities in accord ance with the rec...

Страница 8: ...es and rm shoes with nonslip soles strong long trou sers ear defenders and goggles Never operate the implement while bare footed or when wearing open sandals Never operate the implement if it is damag...

Страница 9: ...ut a visual inspection of the power and extension cables for signs of dam age or ageing lf the power cable for this equipment is damaged it must be replaced by the manufacturer a customer service agen...

Страница 10: ...n accidental start up of the implement the throttle handle 1 is equipped with a safety re lease switch 12 which must be pressed before the On O switch 13 can be pressed lf the On O switch 13 is releas...

Страница 11: ...carry out a general check of the Electric Tiller and remove all residue col lected Before the start of every season it is ab solutely necessary to check the state of the ma chine Contact our Customer...

Страница 12: ...ts in materials or workmanship of the enclosed product Alton Industry Ltd Group will repair or replace any defective materials due to craftsmanship of the product This warranty does not cover any prob...

Страница 13: ...1 0 ELG02 ECOMAX 2022 02 23 Allen 157 145X210 h mm...

Отзывы: