In order to operate the pressure switch, turn the safety clip.
To turn on the torch: press the push-button switch.
To turn off the torch: press the push-button switch. Isolate the switch
from unintentional operation by replacing the safety clip.

KEY-OPERATION
Place the key over the clip: The torch will then switch on when pressure
is put on the clip, when the pressure is released the torch switches off.

WARNING
The safety clip should not be used as a securing clip, as in doing so, the
button will be permanently pressed, thereby reducing the battery life.
Furthermore, the synthetic cap on the switch may also be damaged.

REPLACEMENT OF LED:
When replacing the LED ensure that only the following type is used:
Gallium-Nitrit LED (see technical data)
The LED must only be changed outside the Ex-hazardous area.
The use of any other type of LED is strictly forbidden in that it will
invalidate the Ex-data certification.
Unscrew the LED-protective cap in an anticlockwise direction. Remove
the synthetic ring. Remove the defective LED and replace with a new
one and test by operating the push-button switch.
Refit the synthetic ring and protective cap - screwing in a clockwise
direction.

REPLACEMENT OF BATTERIES:
When replacing the batteries ensure that only the following type is used:
3 x LR44 according to IEC (see technical data)
The batteries must only be changed outside the Ex-hazardous area.
The use of any other type of batteries is strictly forbidden in that it will
invalidate the Ex-data certification.
Keeping the torch in a horizontal position, unscrew the battery cap in an
anticlockwise direction. Next, tilt the torch to remove the defective
batteries, replace with new ones - taking care to ensure correct polarity.
The positive pole should be the one visible.
Refit the cap - screwing in a clockwise direction.

Содержание Lite-Ex LED 8

Страница 1: ...Operating Instructions Lite Ex LED 8 ...

Страница 2: ...ing to IEC CENELEC TÜV Authorisation also classified as either Zone 2 1 and 0 according to NEC FM Approved 2 SAFETY ADVICE Safe operation of the equipment is maintained providing that all instructions and warnings contained in this manual are fully observed In case of doubt due to translation and or printing errors reference should be made to the original German instruction manual 3 FAULTS AND DAM...

Страница 3: ...n the regulations and that improper and incorrect use of the unit is avoided The device must not be opened within the Ex hazardous area Batteries see technical data must only be changed outside the Ex hazardous area The LED see technical data must only be changed outside of the Ex hazardous area 5 EX DATA Certificate of Confomity TÜV 01 ATEX 1692 Certification II 2 G EEx ia IIC T4 Permitted for Zo...

Страница 4: ...atteries 3 x cell type LR 44 according IEC Alkaline manganese LED Type Gallium Nitrit LED NSPW500BS Manufacturer Nichia Corporation Brightness 5 600 mCd Outflow Angle 15 Durability 100000 operating hours Wavelength 455 nm 12 Description Manufacturer LR44 Power Cells Alkaline Panasonic V13GA Electronics Varta LR44 Alkaline Duracell A76 Alkaline Cell GP L1154 Alkaline Cell Vinnic AG13 Battery Chrome...

Страница 5: ...azardous area The use of any other type of LED is strictly forbidden in that it will invalidate the Ex data certification Unscrew the LED protective cap in an anticlockwise direction Remove the synthetic ring Remove the defective LED and replace with a new one and test by operating the push button switch Refit the synthetic ring and protective cap screwing in a clockwise direction REPLACEMENT OF B...

Страница 6: ...osure to improper handling Guarantee claims can only be granted if the defective equipment is returned We reserve the rights to repairs new adjustments or exchanges of equipment The existing regulations are the only right to compensation and are valid exclusively in place of all other contractual or legal guarantees ECOM takes no responsibility for special unavoidable or consequential damage such ...

Страница 7: ...ectrical apparatus for potentially explosive atmospheres General requirements EN 50020 1994 Electrical apparatus for potentially explosive atmospheres Intrinsic safety i EN 50081 1 1993 Electromagnetic compatibility EMC generic emission standard EN 50082 1 1997 Electromagnetic compatibility EMC Generic immunity standard ECOM Rolf Nied GmbH Assamstadt den 13 11 01 12 APPROVAL REPORT FLASHLIGHT LITE...

Страница 8: ...16 13 CERTIFICATE OF CONFORMITY 16 ...

Страница 9: ...17 ...

Страница 10: ...Z Nr 540B0202 11 01 Änderungen vorbehalten ecom instruments GmbH Industriestr 2 D 97959 Assamstadt Tel 49 0 6294 42 24 0 Fax 49 0 6294 42 24 90 E Mail sales ecom ex com Internet www ecom ex com ...

Отзывы: