11
The safety and integrity of the unit may be compromised by,
for example:
- External damage to the housing.
- Exposure to excessive loads.
- Incorrect storage of the unit.
- Damage sustained in transit
- Correct certification is illegible.
- Functioning errors occur
- The permitted limitations are exceeded
4. SAFETY REGULATIONS
The use of the intrinsically safe Lite-Ex LED 8 meets the requirements of
the regulations providing that the user observes and applies the
requirements as laid down in the regulations and that improper and
incorrect use of the unit is avoided.
The device must not be opened within the Ex-hazardous area.
Batteries (see technical data) must only be changed outside the Ex-
hazardous area.
The LED (see technical data) must only be changed outside of the
Ex-hazardous area.
5. EX-DATA
Certificate of Confomity:
:
TÜV 01 ATEX 1692
Certification
:
II 2 G EEx ia IIC T4
Permitted for Zone 1, Equipment group II, Gas group C hazardous
gases, vapour or mist, Temperature class T4.
Report Job Identification No.:
3010859
FM-Certification:
Class I Zone 0 AEx ia IIC T4
I.S. Class I Division 1 Group A-D T4
Permitted for Zone 0, Equipment group II, Gas group C,
Temperature class T4.