background image

9

10. Disposal

Old electrical devices as well as „historical“ old electrical devices from ecom instruments GmbH are 
supplied for disposal at our expense and disposed of free of charge in accordance with European Directive 
2002/96/EC and the German electrical law of 16/03/2005. The costs associated with returning devices to 
ecom instruments GmbH are to be borne by the sender.

In accordance with Article 1, Section 18 and Article 2 of the Act revising the law of Waste-Related Product 
Responsibility for Batteries and Accumulators (Gesetz zur Neuregelung der abfallrechtlichen Produktver-
antwortung für Batterien und Akkumulatoren) dated 25 June 2009, we are obligated to provide the following 
information.

Your device contains an alkaline battery.
Depleted batteries should never be disposed of along with normal or household waste. Old batteries can 
contain harmful substances that are hazardous to health and damaging to the environment. Please return 
the batteries. Return is free of charge and required by law. Please only dispose of discharged batteries in 
the designated containers.

Note: The battery used in this unit poses a fire hazard and can cause chemical injuries if it is used impro-
perly. Neither the battery nor the battery cells should be opened or disassembled and they should not be 
burned or exposed to temperatures exceeding 100°C.

If the battery needs to be disposed of, it can be removed as described under point (8.7). The disposal regu-
lations specified above are also applicable for old devices.
All batteries can be recycled. Precious raw materials such as iron, zinc and nickel can therefore be reused. 

The symbol

has the following meaning: Batteries and rechargeable batteries should not be disposed of 

along with normal or household waste.

11. Cleaning, maintenance and storage

-  Only use a suitable cloth or sponge to clean the unit.  

Do not use any solvents or abrasive cleaning agents when cleaning.

-  It is recommended that you have the functionality and accuracy of the unit inspected by the manufacturer 

every two years.

- The battery should be removed from the unit during prolonged periods of storage.
- Do not allow storage temperatures to exceed or fall below the permitted range of –20 °C to +65 °C!

12. Warranty and liability

In accordance with our general terms and conditions ecom instruments GmbH provides a warranty for this 
product for a period of two years regarding its function and material under the specified and permitted ope-
rating and maintenance conditions. This excludes all parts that are subject to wear and tear (e.g. batteries, 
probes, calibration units, LEDs, etc.). 

This warranty does not extend to products that are used improperly, have been modified, neglected, dama-
ged in accidents or exposed to abnormal operating conditions and inappropriate handling.

Any claims under the warranty can be invoked by returning the defective equipment to the manufacturer. 
We reserve the right to repair, adjust or exchange the device.
The aforementioned warranty conditions are the sole and only right of the purchaser to compensation, 
are exclusively valid and replace all other contract or legal warranty obligations. ecom instruments GmbH 
assumes no liability for special, direct, indirect, accompanying or consequential damage as well as losses 
including the loss of data, independent of whether it was caused by violation of the warranty obligation, 
lawful or unlawful action, action in good faith or any other action.

Содержание Ex-MP4 a

Страница 1: ...1 Z o n e 1 Manual de instruçoes Bruksanvisning Intrinsically Safe temperature meter Ex MP4 a Operating Instructions ...

Страница 2: ...ions for conducting measurements in zone 0 4 5 Safety precautions 5 6 Ex Data 5 7 Specifications 5 7 1 Table with type approved batteries 5 8 Functional description operating instructions 5 8 1 Mode of operation 6 8 2 Structural overview 6 8 3 Optical diagram and field of sight 6 8 4 Operation of the laser sight 7 8 5 Operating the unit 7 8 6 Emission level 8 8 7 Battery replacement 8 8 8 Troubles...

Страница 3: ...tions are illegible malfunctions occur obvious measuring inaccuracies occur it is not possible to conduct any more measurements with the unit permitted limit values have been exceeded 4 Safety regulations Use of this unit assumes that the operator observes the conventional safety regulations and has read the certificate in order to eliminate faulty operation of the unit The following safety regula...

Страница 4: ...95 Smallest display unit 0 2 C Target sighting Laser Accuracy 18 C 1 C 3 C at 23 C 1 C 400 C 2 of reading or 2 C whichever is greater Repeatability 2 of reading or 2 C whichever is greater Spectral response 7 18 µm Response time 95 500ms Batteries power supply 1 x 9V alkaline battery according to IEC 6LR61 type tested 7 1 Table with type approved batteries Manufacturer Model Panasonic EVOLTA Panas...

Страница 5: ...a wider parameter Objects with radiant or polished surfaces not only radiate energy but also reflect a proportion of radia tion from their surrounding area A factor between 0 1 and 1 0 designated as the emission level makes allowances for this factual calculation so that only the true radiated energy and not the reflected energy is consulted for calculating the measured value The majority of appli...

Страница 6: ...nce dependent and can be inferred from the optical diagram in this manual The units are equipped with a robust solid state laser which is housed inside the unit itself 8 5 Operating the unit C deg F deg Change over In order to switch between centigrade and fahrenheit the battery compartment has to be opened having first taken off the leather case It is then possible to select the temperature indic...

Страница 7: ...symbol appears on the display If this occurs the battery should be changed in order to ensure safe operation The battery should only be exchanged outside the Ex area When changing the battery make sure that only those batteries specified in this manual are used see point 7 1 Table with type tested batteries The use of different batteries is strictly prohibited To open the battery compartment first...

Страница 8: ...eused The symbol has the following meaning Batteries and rechargeable batteries should not be disposed of along with normal or household waste 11 Cleaning maintenance and storage Only use a suitable cloth or sponge to clean the unit Do not use any solvents or abrasive cleaning agents when cleaning It is recommended that you have the functionality and accuracy of the unit inspected by the manufactu...

Страница 9: ...id for every purchaser Should any such clause of these warranty conditions be declared ineffective or unenforceable by a competent court then the effectiveness or enforceability of any of the other conditions of these warranty conditions shall remain unaffected by such a judgement 13 EC Declaration of Conformity Further details regarding the Declaration of Conformity can be found at http www ecom ...

Страница 10: ...einschaft Name address of the manufacturer in the EC Nom et adresse du fabricant dans l Union Européenne ecom instruments GmbH Industriestraße 2 97959 Assamstadt Germany Beschreibung der Geräte Description of the devices Description des appareils Eigensicheres Temperaturmessgerät Intrinsically Safe Non Contact Temperature Meter Thermomètre Ex à mesure sans contact Typ Type Ex MP4 a Ex Kennzeichnun...

Страница 11: ...esse de l organisme certifié b Système d assurance qualité pour la fabrication selon la directive 94 9 CE ATEX Physikalisch Technische Bundesanstalt Bundesallee 100 38116 Braunschweig Germany Kenn Nummer Identification number Numéro d identification 0102 Angewandte harmonisierte Standards Applied harmonized standards Standards harmonisés appliqués EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60079...

Страница 12: ...70 ...

Страница 13: ...71 ...

Страница 14: ...rrectness or completeness of the contents of this document including but not restricted to the tacit guarantee of market suitability or fitness for a specific purpose unless applicable laws or court decisions make liability mandatory ecom instruments GmbH reserves the right to make changes to this document or to withdraw it any time without prior notice PA000378 03 2015 WEEE Reg Nr DE 934 99306 11...

Отзывы: