20

- permitted limit values have been exceeded.

4. Safety regulations

Use of this 

x.

com

 explosion-shielded mobile phone assumes that the operator observes the 

conventional safety regulations and has read the certificate in order to eliminate faulty operation 
of the unit.

The following points are to be observed:

-  The unit may not be opened inside the Ex-area; the side cover should not be unscrewed
- The battery module may not be changed inside the Ex-area!
-  The battery module may only be charged outside the Ex-area and only then using the  

following appropriate chargers: universal charger LGX 00, desktop charger DCX 00, Car-Kit 
CKX 00, car charger ALX 00

- The battery module may only be charged in a temperature range of 0 °C - 45 °C.
- Only accessories approved by ecom instruments GmbH may be used.
- The 

x.

com

 5xx -Ex and 6xx -Ex is not waterproof, therefore keep it dry!

-  Observe the corresponding laws that are in force in the respective country regarding the use 

of mobile phones while operating a vehicle!

- Use of the mobile phone in an airplane is not permitted!
-  Switch off the mobile phone when in close proximity to medical instruments and if you are 

requested to do so by corresponding regulations!

-  Manufacturers of cardiac pacemakers recommend a minimum distance of 15.3 cm (6“) is 

maintained between a mobile phone and a pacemaker.

-  Do not switch on the mobile phone when the use of such devices is prohibited, as it may 

cause interference or result in danger.

Содержание x.com 500-Ex

Страница 1: ...x com 500 501 Ex x com 510 511 Ex x com 600 601 Ex x com 610 611 Ex Safety instructions...

Страница 2: ...the battery 24 7 1 3 Charging the battery 25 7 2 Safety information 26 8 Repair 26 9 EC Declaration of Conformity 26 10 Declaration of conformity x com 5xx Ex 27 11 EC Type Examination Certificate x...

Страница 3: ...ate regulations Please read these operating and safety instructions carefully before starting to use the unit In case of any doubt in the form of translation or printing errors the German language ope...

Страница 4: ...CKX 00 car charger ALX 00 The battery module may only be charged in a temperature range of 0 C 45 C Only accessories approved by ecom instruments GmbH may be used The x com 5xx Ex and 6xx Ex is not w...

Страница 5: ...cloth diluted soapy water or commercially available handwash It must be ensured that the unit is not taken into zones 0 and 1 or 20 21 and 22 Only valid for model x com 60x Ex Only the original batte...

Страница 6: ...T130 C II 3G Ex ic IIC T4 x com 50x Ex and x com 51x Ex Approved for zone 2 device group II explosion group IIC explosive gases vapours or mist temperature class T4 Only x com 50x Ex Approved for zon...

Страница 7: ...g IP64 7 Battery 7 1 Changing the battery The AMX 5x or 6x for the x com unit may only be changed outside the Ex area The model number AMX 60 may be followed by additional letters or numbers which are...

Страница 8: ...y plug x com 60x Ex not applicable for x com 51x Ex and x com 61x Ex turn the mobile phone 7 1 2 Inserting the battery Proceed as follows to insert the battery Insert the battery module with the two c...

Страница 9: ...follows to charge the battery Connect the charger to a wall outlet Insert the end of the charging plug into the designated charging socket The phone s battery will now be charged The battery symbol i...

Страница 10: ...ts GmbH for inspection Attention Extreme temperatures can have an adverse effect on charging the battery module AMX 5x or AMX 6x Do not dispose of the battery module in a fire Do not short circuit the...

Страница 11: ...The basic health and safety requirements are met by virtue of conformance with EN 60079 0 2006EN 60079 11 2007 EN 61241 0 2006 EN 61241 11 2006 10 If the certification number is followed by an X then...

Страница 12: ...C Models and classification Device type X com 50x Ex X com 51x Ex Designation II 3G Ex ic IIC T4 II 3D Ex icD 22 T130 C Ta 20 C 50 C II 3G Ex ic IIC T4 Ta 20 C 50 C Covering of the interface Interfac...

Страница 13: ...Only the AMX 50 or AMX 51 battery modules may be used 4 Opening or changing the battery modules is not permitted within the explosive area 5 The interface cover of the X com 50x Ex must be firmly sec...

Страница 14: ...ic health and safety requirements are met by virtue of conformance with EN 60079 0 2006 EN 60079 11 2007 EN 61241 0 2006 EN 61241 11 2006 10 If the certification number is followed by an X then this i...

Страница 15: ...safe Transmitting power up to 2W permissible ambient temperature range 20 C to 50 C 16 Test report no ZELM Ex 1000724606 17 Special conditions 1 The safety instructions are to be observed 2 The devic...

Страница 16: ...e and they should only be charged outside the explosive area using the corresponding charging accessory The housing protection rating for the X com 60x mobile phone is IP 64 In the future the explosio...

Страница 17: ...the AMX 60 or AMX 61 battery modules may be used 4 Opening or changing the battery modules is not permitted within the explosive area 5 The interface cover of the X com 60x Ex must be firmly secured i...

Страница 18: ...nschlie lich aber nicht beschr nkt auf die stillschweigende Garantie der Markttauglichkeit und der Eignung f r einen bestimmten Zweck es sei denn anwendbare Gesetze oder Rechtsprechungen schreiben zwi...

Отзывы: