changed as per the original smoke detector manufacturer’s instructions. Always test the audio detector and smoke alarms after battery
installation to confirm proper operation
LEARN BUTTON
6” MAX
TAMPER SWITCH
MARKINGS TO LINE
UP WITH EXISTING SMOKE DETECTOR
BATT
IMAGE 1
: ENROLLING / TEST / TAMPER BUTTON
IMAGE 2
: INSTALLATION DISTANCE
IMAGE 3
: SIDE MARKINGS
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Re-orient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Connect the equipment to an outlet on a different circuit from the receiver
•
Consult the dealer or an experienced radio/TV contractor for help.
WARNING:
Changes or modifications not expressly approved by Ecolink could void the user’s authority to operate the equipment.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may
not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the
device.
C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes:
(1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement de la dispositif.
FCC ID: XQC-WST601 IC:9863B-WST601
WARRANTY
Ecolink warrants that for a period of 2 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by
shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized
modifications. If there is a defect in materials and workmanship under normal use within the warranty period Ecolink shall, at its option, repair or replace the defective equipment upon return of
the equipment to the original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed
or implied and of all other obligations or liabilities on the part of Ecolink neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this
warranty, nor to assume for it any other warranty or liability concerning this product. The maximum liability for Ecolink under all circumstances for any warranty issue shall be limited to a
replacement of the defective product. It is recommended that the customer check their equipment on a regular basis for proper operation.
THE LIABILITY OF ECOLINK , OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM DETECTOR OR UNDER THE TERMS OF THIS
LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF A SMOKE ALARM DETECTOR AND, IN NO CASE, SHALL ECOLINK , OR ANY OF ITS PARENT
OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSSES OR DAMAGES RESULTING FROM THE FAILURE OF THE SMOKE ALARM DETECTOR OR FOR BREACH OF
THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.
The audio detector does not detect the presence of smoke, heat, or fire directly. It relies solely on the presence of an audio alarm signal generated by an existing smoke or fire
detector in proximity to the audio detector to make such a determination. The audio detector must be used with smoke detectors certified according to UL Standards, and in strict
accordance with the installation and operation instructions provided with such detectors. It is the owner’s responsibility to ensure that smoke or fire detectors used in conjunction with
the audio detector are maintained and tested on a regular basis in accordance with the manufacturer’s instructions. Ecolink expressly disclaims any responsibility for the failure of the
audio detector to detect the presence of smoke or fire due to the failure of any smoke or fire detector used in conjunction with the audio detector to operate properly due to any
condition, including improper installation, operation, maintenance or testing of such smoke or fire detector.
Ecolink Intelligent
Technology, Inc.
2055 Corte Del Nogal
Carlsbad, CA
855-432-6546
PN WST-601 R1.00
REV DATE: 5/20/14
patent pending