background image

CS-202 Wireless Contact  

 

Specifications 
Frequency: 345MHz  

 

 

Operating Temperature: 32°-120°F (0°-49°C) 

Battery: 3V lithium CR2032    

 

Operating Humidity: 5-95% RH non condensing 

Battery life: 5-8 years  

 

 

Compatible with Honeywell receivers 

Magnet gap: 5/8

th

 inch max   

 

Supervisory signal interval: 60 min(approx.) 

 
Enrolling 
To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual 
for details on these menus. When prompted by the panel, trigger the sensor by moving the 
magnet in and out of range of the sensor. The panel will beep when you have successfully learned 
in a sensor.  
 
Mounting 
Included with the contact is double sided tape for the contact and the magnet. For reliable 
bonding ensure the surface is clean and dry. Apply the tape to the sensor and then to the desired 
location. Apply firm pressure for several seconds. It is not recommended to mount the tape at 
temperatures below 50°F, although after 24 hours the bond will hold at low temperatures. 
 
One side of the sensor is marked with 3 lines; this indicates the location of the reed switch. The 
magnet should be mounted facing this side of the sensor, and it must be no further than 5/8 of an 
inch from the sensor. 
     
Replacing the Battery 
When the battery is low a signal will be sent to the control panel. To replace the battery: 
 
1.

 

Slide the top cover to disengage it from the sensor, then remove it to reveal the battery. 

2.

 

Replace with a CR2032 battery ensuring the + side of the battery faces towards you. 

3.

 

Re-attached the cover, ensure the Top (as marked on the inside of the cover) points away 
from the battery. You should hear a click when the cover engages properly. 

Note: Removing the cover will trigger a zone tamper signal to the control panel

 

 

 

Отзывы: