- 2 -

Dimmer Instructions

THIS FIXTURE IS DIMMABLE BY SPECIFIC FORWARD PHASE ELECTRONIC 

(TRAIC) DIMMERS. 

Dimmers tested to be compatible with this fixture are 

the Lutron: Diva® C*L™: DVWCL-153P* or DVCL-153P*, Lumea® C*L™: 

LGCL-153P*, and Toggler® C*L™: TGCL-153P*. Not recommended for use 

with motion or light sensors, timers, or any other external controls.

Important Safety Instructions

This unit has a polarized plug (one blade is wider than the other) as a safety feature. This plug 

will only fit in a polarized outlet one way. If the plug does not fit completely into the outlet, 

reverse the plug. If it still does not fit, contact a qualified electrician. Never use with a power 

strip unless the plug can be completely inserted. Do 

NOT

 attempt to defeat this feature.

WARNING

: To reduce the risk of FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS:

1.   For 

INDOOR USE ONLY

.

2.   Do NOT touch LEDs.

3.   Do NOT remove the protective clear LED lens.

4.   Do NOT look directly at lighted LEDs for any length of time. 

5.   Do NOT touch, operate, or install fixture while in contact with water.

6.   Not intended for illumination of aquariums.

7.   Not intended for recessed installation in ceilings or soffits.

8.   Do NOT mount over sinks or stoves.

9.   Do NOT mount the fixture to cabinets having a material thickness less than 1/4 in.

10. Do NOT install the fixture inside of enclosed cabinets.

11. Electrical requirements:120 V AC, 60 Hz, 0.17 A MAX.

12. Do NOT attempt to install while plugged in.

13. Do not use an extension cord.  Use a power strip with integral over current 

      protection to supply power to the fixture.

14. Use only insulated staples or plastic ties (not included) to secure the cords.

15. Do not run ANY cords behind walls, ceilings, soffits, cabinets or a similar 

      permanent structure where it may be inaccessible for examination.

16. The total wattage of ALL the fixtures linked together in one chain should NOT 

       exceed 360 watts. Exceeding the total wattage will result in a hazardous situation.

17. Do not leave bare wires exposed outside of the electrical compartment.

SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO YOUR FIXTURE TO 

REFER TO THEM AT A LATER TIME.

Plug-in Installation

Find a suitable location to mount the fixture that will reach the power supply.

The fixture uses captive mounting screws which are 

preinstalled on the inside of the wire compartment. To locate 

these mounting screws first remove the screws from both 

sides of the wire compartment cover (

Fig. 1

). 

Once the screws are removed place the cover 

aside to expose the wire compartment and the 

captive mounting screws (

Fig. 2

). These will be 

located on both ends of the wire compartment.  

1

2

The fixture can be mounted in two ways. For installation using 

pilot holes for the screws place the fixture firmly against the 

mounting surface. While holding in position, mark the surface 

for the pilot hole locations by turning both screws until they 

dimple the surface. Using a 1/16” drill bit, drill the pilot holes 

for the screws. Secure the fixture to the cabinet by tightening 

the mounting screws into the drilled pilot holes. The fixture 

can also be mounted without the use of pilot holes by firmly 

holding the fixture against the mounting surface and turning 

the mounting screws until the fixture is snug against the 

surface (

Fig. 3

). Once fixture is secured to cabinent replace 

the wire compartment cover (

Fig. 4

). Plug in the power cord 

and the installation is complete.

3

5

Fig. 1

Fig. 2

Direct Wire Installation  

Disconnect power to the electrical box and remove the old fixture. If more than two 

wire leads are present, keep track of which wires were connected together.  

WARNING

: DISCARD THE POWER CORD to avoid a dangerous situation.

1

The fixture uses captive mounting screws which are 

preinstalled on the inside of the wire compartment. To locate 

these mounting screws first remove the screws from both 

sides of the wire compartment cover (

Fig. 1

).

Fig. 1

Fig. 3

Fig. 4

Fig. 6

Fig. 5

WARNING

: Do NOT plug the power cord into the power 

supply before completing the installation. The power cord has 

a traditional grounded plug at one end and a cord connector 

plug at the other end. Insert the cord connector plug into the 

power port located near the ON/Off switch at the end of the 

fixture (

Fig. 6

). The cord connector plug will ONLY fit into this power port. When correctly 

inserted the catch on the top of the cord connector plug will click into the power port.

 

Plug in the power cord and the installation is complete.

Using a flathead screwdriver, carefully pry off the plastic 

cap that covers the power port on the fixture (

Fig. 5

). 

4

Содержание 708504

Страница 1: ...Nécessaire Se necesita Safetyglasses Lunettesdesécurité Gafasdeseguridad Flatheadscrewdriver Tournevisàtêteplate Destornilladordecabezaplana Phillipsscrewdriver Tourneviscruciforme DestornilladorPhillips Installationtime 45minutes Tempsd installation 45minutes Tiempodeinstalación 45minutos Drillbits1 16in Foretsde1 16po Brocasparataladrode1 16pulg Electricaltape Rubanisolant Cintaaislante Drill Pe...

Страница 2: ... the fixture that will reach the power supply The fixture uses captive mounting screws which are preinstalled on the inside of the wire compartment To locate these mounting screws first remove the screws from both sides of the wire compartment cover Fig 1 Once the screws are removed place the cover aside to expose the wire compartment and the captive mounting screws Fig 2 These will be located on ...

Страница 3: ...ure wire leads using the supplied wire nuts The black leads from the fixture go to the black supply lead and the white leads from the fixture go to the white supply lead Fig 9 Tighten the wire nuts properly to prevent the wires from coming loose If unsure of tightness tape the wire nuts to the wire using electrical tape Fig 10 Carefully push any excess wiring back inside the fixture 4 5 6 7 Fig 7 ...

Страница 4: ... 2 cet appareil doit accepter toute interférence reçue y compris les interférences pouvant entraîner un fonctionnement indésirable Français Ecolight 5260 Capitol Drive Wheeling IL 60090 Printed in China 6 YEAR LIMITED WARRANTY The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of 6 years from the date of original purchase by the consum...

Страница 5: ...n détecteur de mouvement un capteur de lumière une minuterie ou toute autre commande externe 5 Instructions pour le branchement Trouvez un emplacement adéquat pour le luminaire de façon à être en mesure de le brancher sur la source d alimentation Le luminaire est muni de vis de montage imperdables préinstallées à l intérieur du compartiment des fils Pour repérer ces vis de montage retirez d abord ...

Страница 6: ...as de réutiliser les connecteurs à sertissage une fois qu ils ont été retirés Utilisez les capuchons de connexion vissables fournis Le luminaire doit être mis à la terre de façon correcte pour des raisons de sécurité ainsi que pour assurer un fonctionnement approprié Contactez un électricien professionnel si vous ne savez pas comment mettre correctement votre luminaire à la terre Un fil en cuivre ...

Страница 7: ...aporisez pas de produit nettoyant directement sur les pièces du luminaire ou sur les ampoules à DEL Gardez ce guide sous la main pour commander des pièces de rechange Trousse de quincaillerie ZH UC1040F14 BR2 ZH UC1040F22 BR2 S il vous manque une pièce ou si vous avez des questions concernant l installation veuillez visiter notre site web au www goodearthlighting com support ou communiquer avec no...

Страница 8: ...ice solamente grapas aisladas o amarres plásticos no se incluyen para fijar los cables 15 NO coloque cables detrás de paredes techos sofitos gabinetes u otra estructura permanente similar en donde no se pueda acceder a estos para su revisión 16 El vataje total de TODAS las lámparas unidas en una cadena NO debe exceder los 360 vatios Superar el vataje total producirá una situación peligrosa 17 NO d...

Страница 9: ...nza cortacables para cortar directamente cada cable debajo de los conectores engarzados Fig 8 Cuando realice los cortes debe asegurarse de que el cable de suministro es lo suficientemente largo para completar la conexión Después de retirar el empalme plástico despegue aproximadamente 9 53 mm de los aislantes NOTA No retire los engarzadores de los conectores ni trate de usarlos nuevamente Utilice l...

Страница 10: ...rabajo en la lámpara corte el suministro de electricidad en el panel del interruptor de circuito para evitar descargas eléctricas Problema Causa Solución La lámpara no enciende No hay alimentación Compruebe si el suministro de electricidad está activado La conexión es deficiente Revise los cables o el cableado El interruptor es incorrecto Pruebe o reemplace el interruptor Cuando se enciende la luz...

Отзывы: