Eng

lis

h (

EN

)

3.  When installing the piping, take care to avoid air traps.

4.    Max. supply water temperature: 40°C 

 

Max. water supply Inspexx: 50 l/min 

 

Max. allowed inlet water pressure: 5 bar

5.3. Bleeding the pump

WARNING

Never start up the supply pump before 

the pump has been bled. 

When the unit has been mounted and water has been 

connected to the inlet side, the pump must be bled. This is 

done by opening the bleeding screw in the top of the pump. 

Operate the valve for the dosing pump and fill the tank with 

water and bled the supply pump. The pump must be bled 

until only water comes out of the pump. 

6. 

 Setting before use - Operation

6.1. 

 Setting before use

When delivered the unit is pre-set for use. For the Inspexx 

this means that the tank will be automatically refilled and 

that the pump will start up when flow appears in one or 

more outlets. Further, the pump will stop when the flow 

ends. 

Via a signal from a pressure sensitive switch the pumps 

starts up and stops running via a signal from a flow switch. 

The pressure sensitive switch is pre-set by the supplier. 

The flow switch might have to be fine tuned. 

The adjustment of the flow switch is carried out as follows: 

open up one outlet, adjust the flow switch screw until one 

yellow diode and one green diode lights up. This must cor-

respond the min. achievable consumption.

Concentration of detergent is to be adjusted directly on the 

inlet of the dosing pump. For further data and service on 

the dosing pump please see data sheet and manual for the 

dosing pump.

6.2. Daily operation

When adjusted according to the above descriptions the unit 

runs automatically. This means that the tank automatically 

is refilled and that the pump, during flow in one or more 

outlets, is in operation.  

Before using the outlet always connect a disinfection noz

-

zle or foam nozzle to the pistol/closing valve. 

Only seconds after opening of the pistol/low pressure valve 

the pump starts up and a working pressure automatically 

appears. 

4.  Overview and use

The Inspexx unit consists of a dosing system – mixing 

water and chemicals. The mixed solution is led into 

a tank (the pre-diluted solution). From this tank the 

solution is pumped out to outlets where the solution is 

used for cleaning. 

For the Inspexx the liquid level in the tank is adjusted 

via level sensors placed inside the tank. These sen-

sors send a signal to the controller operating the 

valve and the dosing pump leading the water into the 

tank. 

The unit is made of corrosion resistant material – 

mainly stainless steel and plastic – and is   therefore 

especially suitable for application within the food 

industry. 

5.  Installation

5.1. Directions for mounting of the Inspexx unit

ATTENTION

1.  The unit should be mounted in frost free rooms 

only.

2.  The unit is leveled by adjusting the feet. When 

the unit is leveled the lock nuts on the feet are to 

be tightened thoroughly. 

3.  The unit is fastened to the floor using a bolt 

through the hole on each foot. It is sufficient to 

fasten the feet in the corners.

5.2. Water connection

CAUTION

1. 

Before the station is connected to the water sup

-

ply pipe, the supply line should be rinsed care-

fully in order to remove coarse impurities and 

metal shavings.

2.  The pressure loss in the supply line should be 

held as low as possible by:

- avoid long supply pipes

- mounting of low pressure resistance ball valves and

- avoiding fittings with high pressure loss

Содержание Inspexx

Страница 1: ...Inspexx Mixing System Directions for use Gebrauchsanweisung...

Страница 2: ......

Страница 3: ...F rs kran om verensst mmelse Vaatimustenmukaisuusvakuutus Overensstemmelseserkl ring Deklaracja zgodno ci Megfelel s gi nyilatkozat Izjava o skladnosti Izjava o uskla enosti Deklaracija o konformitetu...

Страница 4: ...del Consiglio riguardanti il riavvicinamento delle legislazioni degli Stati membri CE Direttiva Macchine 2006 42 EC EN 60335 2 79 2012 Direttiva EMC 2014 30 EU EN 55014 1 2007 EN 55014 1 2015 EN 61000...

Страница 5: ...y d s ujednoli cenia przepis w prawnych kraj w cz onkowskich WE Dyrektywa Maszynowa 2006 42 WE EN 60335 2 79 2012 Dyrektywa EMC 2014 30 EU EN 55014 1 2007 EN 55014 1 2015 EN 61000 3 2 2014 EN 61000 3...

Страница 6: ...2007 EN 55014 1 2015 EN 61000 3 2 2014 EN 61000 3 2 2013 Prehl senie o zhode My firma Nilfisk FOOD prehlasujeme na svoju pln zodpoved nost e v robky Inspexx 119000354 na ktor sa toto prehl senie vzt...

Страница 7: ...kt va 2006 42 EK EN 60335 2 79 2012 Elektromagn tisk s sader bas direkt va 2014 30 EU EN 55014 1 2007 EN 55014 1 2015 EN 61000 3 2 2014 EN 61000 3 2 2013 Nilfisk FOOD Inspexx 119000354 2006 42 EN 6033...

Страница 8: ......

Страница 9: ...cations 12 4 Overview and use 13 5 Installation 13 5 1 Directions for mounting of the Inspexx unit 13 5 2 Water connection 13 5 3 Bleeding the pump 13 6 Setting before use Operation 13 6 1 Setting bef...

Страница 10: ...Wear gloves and suitable clothing when using the unit Caution A dangerous situation Possible consequences light or minor injuries Can also be used to warn against damage to prop erty or other goods pr...

Страница 11: ...this user guide thoroughly prior to installation and start of op eration Operation as laid down in the directions for use will ensure an optimum level of hygiene in your factory and a minimum level o...

Страница 12: ...glish EN Water Unit INSPEXX Max operational pressure bar 5 Water flow inlet L min 50 Water flow outlet L min 50 Max temperature of water C 40 Weight kg 100 Dimension WxHxD 1330x1525x725 3 2 Specificat...

Страница 13: ...he unit runs automatically This means that the tank automatically is refilled and that the pump during flow in one or more outlets is in operation Before using the outlet always connect a disinfection...

Страница 14: ...page Fig 2 1 Log out and go back Fig 2 2 My alarm limit for low chemical level Fig 2 3 Shows the amount of chemical in per mille right now Fig 2 4 Max alarm limit for high level of chemical Fig 2 5 S...

Страница 15: ...32 Min Limit for chemical content has been reached stated in per mille 44 USB Stick missing 45 Error on USB Stick 54 Stop mixing tank is empty Pump stops running Fig 3 0 Back to front page Fig 3 1 De...

Страница 16: ...y regulations accident preventing regula tions lines and generally acknowledged technical regulations such as DIN norms and VDE provisions For your safety this cleaning unit has been manu factured acc...

Страница 17: ...ccount All hoses rubber parts or synthetic materials natural wear and tear as well as damage caused by care less and inappropriate handling including transport damage are not covered by the guarantee...

Страница 18: ......

Страница 19: ...kationen 22 4 berblick und Verwendung 23 5 Installation 23 5 1 Anweisungen zur Montage der Inspexx Anlage 23 5 2 Wasseranschluss 23 5 3 Entl ften der Pumpe 23 6 Einstellungen Betrieb 23 6 1 Einstellun...

Страница 20: ...Benutzung des Ger ts Handschuhe und passende Kleidung Vorsicht Eine gef hrliche Situation M gliche Konsequenzen Leichte oder geringf gige Verletzungen Kann auch genutzt werden um vor Sachbesch digung...

Страница 21: ...edienpersonal diese Anlei tung vor Installation und Inbetriebnahme gr ndlich durch liest Der Betrieb wird wie in der Bedienungsanleitung beschrieben ein optimales Hygieneniveau in Ihrem Betrieb und ei...

Страница 22: ...2 English EN 3 1 Spezifikationen Wasser Einheit INSPEXX Max Betriebsdruck bar 5 Wasserstrom Einlass L min 50 Wasserstrom Ablass L min 50 Max Wassertemperatur C 40 Gewicht kg 100 Ma WxHxD 1330x1525x725...

Страница 23: ...ls vor ihrer Entl ftung in Betrieb Wenn die Anlage montiert und Wasser an der Zu laufseite angeschlossen wurde muss die Pumpe entl ftet werden Das erfolgt durch ffnen der Entl f tungsschraube oben auf...

Страница 24: ...Liter Fig 2 0 Zur ck zur Vorderseite Fig 2 1 Ausloggen und zur ckgehen Fig 2 2 Alarmgrenze f r Min Chemieeinhalt Fig 2 3 Wie viel Chemie gibt es im Moment in Promille angegeben Fig 2 4 Alarmgrenze f r...

Страница 25: ...t erreicht in Promille angegeben 44 USB Stick fehlt 45 USB Stick Fehler 54 Stopp Mischbeh lter ist leer Die Pumpe schaltet ab Fig 3 0 Zur ck zur Vorderseite Fig 3 1 Alle Alarme streichen Fig 3 2 Stell...

Страница 26: ...nischen Vorschriften wie die DIN Norm und die VDE Bestimmungen vertraut sind Aus Sicherheits gr nden wurde diese Reinigungsanlage gem aller relevanten in der EU g ltigen Vorschriften gefertigt und som...

Страница 27: ...en S mtlicher Schl uche Gummi und Kunststoffteile nat rliche Verschlei teile sowie Besch digungen die infolge nachl ssiger oder unsachgem er Handhabung einschlie lich Transportsch den eintreten sind n...

Страница 28: ......

Страница 29: ...English EN Recommended spare parts Empfehlenswerte Ersatzteile 29...

Страница 30: ...English EN Spare parts Inspexx 28 37 3 10 4 7 18 29 11 9 20 40 8 1 2 36 35 30 3 38 33 38 31 29 10 4 7 36 9 2 20 8 42 119000354 1 30 English EN...

Страница 31: ...sure sensitive switch 10 313600 Level sensor horisontal 11 639092 Pressure gauge 18 603700 O ring 20 110000973 Flow switch 1 4 28 110004907 Flow sensor 29 110004970 Controller 30 110004968 Oval gear m...

Страница 32: ...Control unit Air Water 1 Controller 2 Flow sensor 3 Ball valve w actuator and solenoid 4 Dosing pump 5 Oval gear meter 6 Tank for detergent 7 Tank for pre diluted detergent 8 Level sensors 9 Ball val...

Страница 33: ...ANALOG OUTPUT 13 GND CONNECTION FOR GRUNDFOS SENSOR 0 10V 0 4 20mA NO C NC SIGNAL RELAY MAX 250V 2A AC1 MIN 5V 10mA CONNECTION FOR PC TOOL DIR REVERSE DIR NORMAL 5 10V 6 GND 3 GND 4 SET POINT 2 RUN ST...

Страница 34: ...English EN 34 110005503 4...

Страница 35: ...English EN 110005503 5 35...

Страница 36: ...English EN 36 110005503 6...

Страница 37: ...English EN 110005503 7 37...

Страница 38: ...English EN 38 Mounting 1522 1328 723 Inlet3 4 Outlet11 4 119000354 2...

Страница 39: ......

Страница 40: ...9 06 2017 Printed in Denmark ECOLAB Engineering GmbH F B Engineering Competence Centre EMEA Raiffeisenstra e 7 D 83313 Siegsdorf Telephone 49 86 62 61 0 Fax 49 86 62 61 2 35 e Mail engineering mailbox...

Отзывы: