10
7. Recommended spare parts
Satellite
Nr.
Description
Amount
0664136
Non-return valve, air
1
0646050
Non-return valve, detergent
1
0603338
Non-return valve, water
1
8. Specifi cations
The most important specifi cations are shown on the serial plates on the main station/satellite and pump, respec-
tively.
Adv.
Water
Unit
Pneumatic SP
Automatic SA
Max. outlet pressure.
bar
40
40
Comsumption during rinsing.
L/min
30
30
Comsumption during foaming.
L/min
10
10
Min. supply prssure.
bar
12
12
Max. supply pressure.
bar
40
40
Min. water supply.
L/min
30
30
Max. water temp.
°C
70
70
Pipe dimension inlet Ø
inch
1/2”
1/2”
Pipe dimension outlet Ø
inch
1/2”
1/2”
Compressed air
Min/Max air pressure
bar
5-10
5-10
Compressed air consumption
NL/min
200
200
Pipe dimension inlet Ø
mm
6
6
General
Dimensions
mm
330 x 403 x 215
330 x 403 x 215
330 x 403 x 215
Weight kg
15
15
15
Electricity
Supply voltage
V
1N/PE 110/230 V
85-0%...265+0%
24 V DC ± 10%
Frequency
Hz
50/60 Hz
48-0%...62+0%
Power
W
3
Содержание Chameleon SA Series
Страница 1: ...Advanced satellite SP SA series Service Manual 3 10 EN...