122
5.4.3.
TIMER SETTING
(
1-24 hours
)
:
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Cancel timer
5.4.4.
Automatic Defrost
At low room temperatures, frost may build up at the evaporator during operation.
The unit will automatically start defrosting and the
POWER
LED blinking. The
defrost control sequence is as follows:
A.
When the unit operates in the cooling operation, drying operation, the
ambient temperature sensor senses the evaporator coil temperature is below
-1 °C, after the compressor will stop operating for 10 minutes or the coil
temperature up to 7
℃
, the unit restart to cool operating mode.
B.
When the unit operates in the drying operation, once the coil temperature
sensor senses the temperature of the evaporator is below 40
℃
and the
differential temperature between coil temperature and room temperature is
below 19
℃
after the compressor operation for 20minutes, the unit start
defrosting for 5 minutes and the power indicator blinking.
Press
Timer
key to
turn on the timer
function.
Press
Timer
key to
turn on the timer
function.
Press
ADD/MINUS
repeatedly to set the
delay OFF time.
Press
ADD/MINUS
repeatedly to set the
delay ON time.
Press
ADD/MINUS
repeatedly until the LED shows ‘00’.
Note: when press
POWER
will also exit the timer setting.
Содержание ecoQ CoolAir 8
Страница 18: ...18 5 BETRIEB 5 1 BEDIENFELD UND DISPLAY...
Страница 20: ...20 5 3 FERNBEDIENUNG...
Страница 31: ...31 ecoQ CoolAir 8 Climatiseur mobile Mode d emploi R frig rant cologique R290 Merci d avoir choisi ecofort...
Страница 49: ...49 5 FONCTIONNEMENT 5 1 PANNEAU DE COMMANDE ET AFFICHAGE...
Страница 51: ...51 5 3 TELECOMMANDE...
Страница 83: ...83 5 FUNZIONAMENTO 5 1 PANNELLO DI CONTROLLO E DISPLAY...
Страница 84: ...84 5 2 TELECOMANDO...
Страница 106: ...106 services...
Страница 117: ...117 5 OPERATION 5 1 CONTROL PANEL AND DISPLAY...
Страница 118: ...118 5 2 REMOTE CONTROL...