![ECOFOREST CS 2012/08 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/ecoforest/cs-2012-08/cs-2012-08_installation-and-maintenance-manual_2354337032.webp)
31
LOCATION AND SAFETY DISTANCES.
4.11.
Do not install the stove in a sleeping room.
4.12.
Install a fire protection between the ground and the stove if the floor is a combustible material.
4.13.
Security distances should be respected when the stove is installed in spaces where materials around it, be it
the construction material itself, the fuel or any other type of materials, are likely to be flammable. Ensuring a
better access to the stove for future maintenance or repair work is also worth considering.
Drawing 4
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
4.14.
Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.15.
The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove’s output.
It is mandatory to install at least
two metres in length vertically
to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1
metre
; greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is
recommendable to install an uninterruptible power supply (UPS) which we have available as an option. This
apparatus only feeds the exhaust vent.
4.16.
Distances from doors, Windows, ventilation grids or air input to the house or building:
Drawing 5
A
Lateral wall.
≥ E
B
Back
of
the
stove.
Minimum
separation that allows visualizing the
label marking the stove.
≥ 80 mm
C
1.5 x depth of stove.
See dimensions
D
Shelf.
≥ 400 mm
E
Depth of stove.
See dimensions
A
Distance from ventilation grid.
500 mm
B
Distance from ventilation grid.
500 mm
C
Lateral side of a window.
1250 mm
D
Top of a window.
650 mm
E
Top of a door.
650 mm
F
Lateral side of a door.
1250 mm
G
Adjacent wall.
300 mm
H
Height from adjacent wall.
2300 mm
I
Adjacent building.
650 mm
Содержание CS 2012/08
Страница 1: ......
Страница 6: ...5 1 ESPECIFICACIONES T CNICAS CANTINA SUPER CS 2012 08 HIDRO 24 HC 2015 HIDRO 16 HB 2015...
Страница 27: ...26 1 TECHNICAL FEATURES CS 2012 08 HC 2015 HB 2015...
Страница 48: ...47 1 SP CIFICATIONS TECHNIQUES CS 2012 08 HC 2015 HB 2015...
Страница 70: ...69 1 SPECIFICHE TECNICHE CS 2012 08 HC 2015 HB 2015...
Страница 92: ...91 1 ESPECIFICA ES T CNICAS CS 2012 08 HC 2015 HB 2015...
Страница 113: ...112...