27
The stove must be tested by Chimeney’s sweeps after the soot fire, before it is reused.
3.
FUEL.
Your stove
is designed to operate
with wood pellets;
however, it can also work with other biomass fuels (ask
your dealer about this). If using a different type of biomass is possible, select it from the fuel selection menu (check
user manual). In most cases, the combustion basket is not the same as for wooden pellets.
ECOFOREST
do not have any control on the quality of the fuel you use. For this reason,
ECOFOREST
cannot
guarantee the full output of your stove nor the eventual premature aging or eventual damage of the gas outlet. The
fuel’s minimum requirements are specified below:
Pellets
Olive pits
Almond shells
Diameter (mm)
6
— —
— —
Length (mm)
5 - 25
— —
— —
Granulometry (mm)
— —
3 - 4
6 - 8
Calorific value (Kcal/kg)
≥ 4300
≥ 3800
≥ 3700
Ash (% mass)
< 1.5
< 1.5
< 1.5
Humidity (%mass)
< 12
< 12
< 12
Oils
— —
No oil content
— —
Burn pot and/or specific strangler.
— —
Consult dealer
— —
4.
INSTALLATION.
The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to
geographic areas.
The installation of the stoves must be done in the same way, for this reason, only the ECO I model will be
exposed. In the same way, air inlets and water connections will be missed in all drawings as section 4.16 indicates
the minimum security distances to be respected for their installation.
ELECTRICAL CONNECTION.
The power socket to which the stove is plugged should meet the following requirements:
4.1.
Ground connection must comply with the specific applicable regulations.
4.2.
Differential switch with the correct amperage. It must comply with the specific applicable regulations (check
technical specifications of the stove).
4.3.
Single-phase AC of ~230/240V – 50Hz and pure sine wave.
4.4.
Easily accessible power socket. If the power socket can’t be accessed due to the characteristics of the
electrical installation, an all-pole disconnection switch must be installed.
4.5.
The power cable provided by
ECOFOREST
is 1.4m long; you might need a longer one. Always use a cable with
ground plug and with an equal or greater section. Make sure the power cable is not placed under the stove
or close to hot or sharp surfaces that could damage it.
UNPACKING THE STOVE.
4.6.
Remove the packaging and the protective plastic.
4.7.
Remove the screws
or bolts
that fasten the stove to the pallet
and remove it.
4.8.
If our model has a plastic protection, it must be removed before starting it.
4.9.
Remove exhaust blower protection.
Содержание Atenas
Страница 1: ......
Страница 111: ...110 9 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE EC UNE EN 14785...
Страница 112: ...111 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE INSERT EE UNE EN 14785...
Страница 114: ...113 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECO II INSERT EAM UNE EN 14785...
Страница 116: ...115 14 MEDIDAS MEASURES MESURES MISURES MEDIDAS ATENAS VR 2012 UNE EN 14785...