 sockets or the car power outlet exceeds the maximum power output of the battery, the overload indicator 
and the indicator of the corresponding socket will flash at the same time for 15s. The EF DELTA will shut 
down automatically. Remove the device causing the overload and restart the EF DELTA to resume operation.

Indicate which ports are in use.

j. Port Usage Indicators

EF DELTA display screen indicates various device protection scenarios with different icons and their 
combinations. 

USB-A icon flashes together with Overload icon. 

Resume normal operation by pulling out electrical 

appliances and waiting for 10 seconds.

USB-C icon flashes together with High-tempera-

ture icon. Resume normal operation of the 

interface by cooling down the machine.

Overload icon flashes. Resume the device to 

normal operation by pulling out electrical 

appliances and restarting.

Recharging time, Exclamation and High-tempera-

ture icons flash together. This happens usually 

after a heavy battery use. Recharging can be 

resumed after battery is cooled down.

Exclamation and High-temperature icons flash 

together. Power supply can be resumed after 

battery is cooled down.  

Exclamation and Low-temperature icons flash 

together. Power supply can be resumed soon 

after moving the device to a warmer place.  

Recharging time, Exclamation and Low-tempera-

ture icons flash together. Recharging can be 

resumed by warming up battery moderately.

Recharging time, Exclamation and Overload icons 

flash together. Pull out the plug, restart the device 

and replug. If the lights keep flashing, please 

contact our product specialists via support@eco-

flow.com.

. Protection Information Instruction

USB-A Overcurrent
Protection 

USB-C High Temperature
Protection 

Device Overload 

High Temperature 
Discharge-protection

High Temperature 
Recharge-protection

Low Temperature
Discharge-protection

Low Temperature
Recharging-protection

Overcurrent
Recharging-protection

8

power a free life

Содержание EF DELTA

Страница 1: ...2 Never disassemble puncture subject the unit to a large shock or crush force or incinerate the EF DELTA or the accessories 3 Do not attempt to disassemble the EF DELTA there are no user serviceable...

Страница 2: ...USE CARE AND SAFETY GUIDE 4 EF DELTA S FEATURES LCD DISPLAY SOLAR PANEL CONNECTION ENTRY LEVEL UPS AND SERIES MODE TECHNICAL SPECIFICATIONS HOW TO RECHARGE EF DELTA FAQs WHAT S IN THE BOX OPTIONAL 6 1...

Страница 3: ...The User must take the same care and precautions when using the Delta as would be taken when using your normal household power and appliances Do not allow children to use the Delta Failure to follow t...

Страница 4: ...ged or malfunctioning Delta If your Delta is functioning abnormally contact EcoFlow support at support ecoflow com for further assistance 4 The Delta must only be used at temperatures between 0 and 45...

Страница 5: ...od 3 DO NOT charge a battery immediately after a long heavy load because the battery s temperature may be too high DO NOT charge a battery until it cools down to near room temperature The battery may...

Страница 6: ...hone Tablet Go Pro Portable Speakers or anything that needs to be changed through a USB A Port The USB A Output Indicator light will automatically light up when a USB A Port is in use 2 USB A Output P...

Страница 7: ...C power and this device consumes battery power just to operate in idle once switched on It is therefore sensible to conserve battery life by switching off the AC power and unplugging any AC power cord...

Страница 8: ...y pack If the Delta has recently been discharged under high load for an extended period of time the charging function will be disabled until the internal battery pack returns to a normal temperature I...

Страница 9: ...the EF DELTA The fan speed of the EF DELTA directly correlates with the load and the ambient temperature The higher the load or the ambient temperature the higher the fan speed will be e Fan Indicato...

Страница 10: ...arging time Exclamation and High tempera ture icons flash together This happens usually after a heavy battery use Recharging can be resumed after battery is cooled down Exclamation and High temperatur...

Страница 11: ...mperature Car and High temperature icons flash together The machine will be resumed to normal operation after it is cooled down Car icon flashes Try to restart the device If the icon keeps flashing pl...

Страница 12: ...w to recharge the EF DELTA using solar panels Users can connect 1 3 pieces of solar panels Up to a maximum of 3 panels in series as shown in the following picture Connect one end of the panels to the...

Страница 13: ...connections are a common mistake will damage the Delta and will not be covered by the warranty 3 EF DELTA supports the use of third party solar panels DIY solution When EF DELTA is used under UPS or m...

Страница 14: ...unit and the other end to the input port of Slave 1 Then connect one end of the AC cable to the AC output port of Slave 1 and the other end to the input port of Slave 2 After connecting the machines t...

Страница 15: ...ast Charge x2 USB C Output x2 Car Power Output x1 Output 5V DC 2 4A 12W Max per port 5V DC 9V DC 12V DC 2 4A 28W Max per port 5V DC 9V DC 15V DC 20V DC 3A 60W Max per port 108 8W 13 6V DC 8A max 1800W...

Страница 16: ...harge my EF DELTA How do I care for EF DELTA Yes EF DELTA can output power while being charged EF DELTA is designed for a variety of uses so EF DELTA needs to be cleaned occasionally Please use a dry...

Страница 17: ...s a water resistant dustproof case for maximum protection It is suggested that you keep EF DELTA connected to a power source such as a solar panel or a wall plug when the product is not in use This ca...

Отзывы: